Concept explainers
The phase sequence for the Y-
a. Find the angles
b. Find the voltage across each phase impedance in phasor form.
c. Draw the phasor diagram of the voltages found in part (b), and show that their sum is zero around the closed loop of the
d. Find the current through each phase impedance in phasor form.
e. Find the magnitude of the line currents.
f. Find the magnitude of the generator phase voltages.
Want to see the full answer?
Check out a sample textbook solutionChapter 24 Solutions
Introductory Circuit Analysis (13th Edition)
Additional Engineering Textbook Solutions
Programmable Logic Controllers
Fundamentals of Applied Electromagnetics (7th Edition)
ELECTRICITY FOR TRADES (LOOSELEAF)
Electric Motors and Control Systems
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
Electric Circuits. (11th Edition)
- In a balanced system, the phasor sum of the line-to-line voltages and the phasor sum of the line-to-neutral voltages are always equal to zero. (a) False (b) Truearrow_forwarda. Y-Connected b. В 100kW Source 0.9 LAG 80KVA 0.8 LAG Figure 1 80kW 0.85 LAGarrow_forward1. What is the main direct cause of reactive power in AC system? A. Resistance of transmission lines B. Inductance and capacitance in the loads C. Ideal transformer connected in the system D. Power produced by generator 2. "Reactive power in a system is dissipated generally as thermal energy?" A. TRUE B. FALSE 3. Which of the following statements are correct for three phase circuit: A. Sum of all the three phase currents is zero in unbalanced network B. Total power transfer to load is constant with time C. Neutral conductor is same size in terms of material used as in single phase conductors D. Net apparent power consumed is equal to real powerarrow_forward
- Three Impedances each of (8 - j24)2 are connected in mesh across a three-phase 420V ac supply. Determine the phase current, line current, active power, reactive power drawn from supply. Also draw the Phasor diagram for the mesh connection and marks the Line current ,phase current line voltage and phase angle between phase current and pahse voltage. phase current (Ip) Line current real power reactive powerarrow_forwardThe values of the elements for the given circuit are given below.What is the maximum average power that can be transferred to the ZL load?R1 = 400 OhmsL = 500j OhmsR2 = 100 Ohmsarrow_forwardUse Millman’s theorem and determine the magnitude of the neutral displacement voltage,(Vsn) in the phasor form. Use Millman’s theorem and determine the phase voltage (Vbs) of the load in polar form. Use Millman’s theorem and determine the phase voltage (Vbs) of the load in polar form. Use Millman’s theorem and determine the current,(Ib) in phase b of the load in phasor form. Use Millman’s theorem and determine the current,(Ib) in phase b of the load in phasor form. Use Millman’s theorem and determine the reading on the wattmeter connected in line B of the circuit.arrow_forward
- Q.2 For unbalanced system each phase is different from other and neutral current depends on phase currents. Compute sequential components of the given phase currents. 1. Ia 1.6 2 30 2. Ib 1.0 Z170 3. Ic= 0.9 150arrow_forwardIn the balanced 3-phase circuit adjacent Find the currents Ia, Ib, Ic and IAB, IBC and ICA. Z1=Z2=Z3=A+iB, A= 752 B= 257 Phase-to-phase voltages are 0-120-240 degrees, respectively, and in this question, The B number (Volts) you get is in amplitude.arrow_forwardDraw a 3-phase wye-connected generator with transmission lines connected to a 3-phase delta-connected load. Assume the lines connecting them have an inductance of j5 per phase. The generated voltages are 120 Vrms with phase 'a' having a phase angle of 0°. The loads are 10 Ohm resistors per phase. When drawing, make sure to label all 3 phases with voltage phasors, line inductances, and load resistances.arrow_forward
- A star connected three phase alternator supplies power to a delta connected resistive load. The alternator has a line voltage of 480V. Each resistor of delta load has 8 ohm of resistance. Find the following values. Line voltage of the load (VL(load)) Phase voltage of the load (VP(load)) Phase current of the load (IP(load)) Line current delivered by the alternator (IL(alt)) Phase current of the alternator (IP(Alt)) Phase voltage of the alternator (VP(Alt)) True powerarrow_forward20) Two AC generators A and B are in Parallel. Each generator has an emf of 1000V per phase and in phase, the phase impedance are ZA = 0.1+j2 ohms, ZB = 0.2+j3.2 ohms respectively. If the common load has an impedance of (2+j1) ohms per phase, solve the voltage per phase at the loadarrow_forwardA 60Hz, single-phase source with V=27730 volts is applied to a circuit element. (a) Determine the instantaneous source voltage. Also determine the phasor and instantaneous currents entering the positive terminal if the circuit element is (b) a 20 resistor. (C) a 10mH inductor, and (d) a capacitor with 25 reactance.arrow_forward
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning