Chapter 24, Problem 45P
To determine
(a)
Magnitude of phase voltage of load.
To determine
(b)
Magnitude of phase and line currents.
To determine
(c)
Magnitude of phase voltage at the source.
To determine
(d)
Magnitude of line to line voltage at the source.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
If in a Y- connected ac generator, each phase voltage has a magnitude of 90 Vrms, what is the magnitude of each line voltage
Select one:
O a. 180 Vrms
O b. None of these
O c.
155.88 Vrms
O d. 90 Vrms
Jim
A three-phase A-connected generator has an inter-
nal impedance of 0.6 + j4.8 N/4. When the load is
removed from the generator, the magnitude of the
terminal voltage is 34,500 V. The generator feeds a
A-connected load through a transmission line with
an impedance of 0.8 + j6.4 N/þ. The per-phase
impedance of the load is 2877 – j864 N.
a) Construct a single-phase equivalent circuit.
b) Calculate the magnitude of the line current.
c) Calculate the magnitude of the line voltage at
the terminals of the load.
d) Calculate the magnitude of the line voltage at
the terminals of the source.
e) Calculate the magnitude of the phase current in
the load.
f) Calculate the magnitude of the phase current in
the source.
In a three phase Y connected generator, the phase voltages are 2 kV. The magnitudes of the line voltages are
Select one:
O a. 3464 V
O b. 6000 V
C. 2000 V
d. None of these
Chapter 24 Solutions
Introductory Circuit Analysis (13th Edition)
Ch. 24 - A balanced V load having a 10 resistance in each...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - Repeat Problem 1 if each phase impedance is...Ch. 24 - The phase sequence for the Y-Y system in Fig....Ch. 24 - Repeat Problem 4 if each phase impedance are...Ch. 24 - Repeat Problem 4 if each phase impedance is...Ch. 24 - For the system in Fig. 24.43, find the magnitude...Ch. 24 - Computer the magnitude of the voltage EAB for the...Ch. 24 - For the Y-Y system in Fig. 24.45: a. Find the...Ch. 24 - For the Y-Y system of Fig. 24.46 the impedance of...
Ch. 24 - A balanced load having a 20 resistance in each...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - Repeat Problem 11 if each phase impedance is...Ch. 24 - The phase sequence for the Y- system in Fig....Ch. 24 - Repeat Problem 14 if each phase impedance is...Ch. 24 - Repeat Problem 14 if each phase impedance are...Ch. 24 - Prob. 17PCh. 24 - For the connected load in Fig. 24.49: a. Find the...Ch. 24 - A balanced V load having a 30 resistance in each...Ch. 24 - Repeat Problem 19 if each phase impedance is...Ch. 24 - Prob. 21PCh. 24 - Prob. 22PCh. 24 - Prob. 23PCh. 24 - Repeat Problem 22 if each phase impedance is...Ch. 24 - Prob. 25PCh. 24 - Prob. 26PCh. 24 - Prob. 27PCh. 24 - The phase sequence for the - system in Fig....Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Repeat Problem 28 if each phase impedance is...Ch. 24 - Prob. 31PCh. 24 - Prob. 32PCh. 24 - Prob. 33PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 35PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - Prob. 38PCh. 24 - Prob. 39PCh. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - A balanced, three-phase, -connected load has a...Ch. 24 - A balanced, three-phase, Y-connected load has a...Ch. 24 - Find the total watts, volt-amperes reactive,...Ch. 24 - The Y-Y system in Fig. 24.53 has a balanced load...Ch. 24 - Prob. 45PCh. 24 - Prob. 46PCh. 24 - Repeat Problem 46 for the network in Fig. 24.47.Ch. 24 - For the three-wire system in Fig. 24.55, properly...Ch. 24 - Sketch three different ways that two wattmeters...Ch. 24 - For the Y- system in Fig. 24.56: Determine the...Ch. 24 - For the system in Fig. 24.57: Calculate the...Ch. 24 - For the three-phase, three-wire system in Fig....
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In a balanced system, the phasor sum of the line-to-line voltages and the phasor sum of the line-to-neutral voltages are always equal to zero. (a) False (b) Truearrow_forwardTwo delta connected loads are connected in parallel and powered by a balanced Y-connectedsource. The smaller of two loads draws 10 kVA at a lagging power factor of 0.75 and the largerdraws 25 kVA at a leading power factor of 0.8. The line voltage is 400 V. Calculate a) The powerfactor at which the source is operating. b) The total power drawn by the two loads. c) The phasecurrent of each load.arrow_forwardAnswer the question the below Image. A single phase transmission line is delivering 500 kVA load at 2 kv. Its resistance is 0-20 and inductive reactance is 0-40. Determine the voltage regulation if the load power factor is 0-707 lagging. O 8.5 % O 7.2 % O 6.4 % O 5.3 % Continuearrow_forward
- In a three-phase balanced Y-Y system, the source phase currents have a magnitude of 9 A. The magnitude of the current on each load is Select one: O a. 9A O b. 12 A O c. None of these O d. 27 A In a three phase Y connected generator, the phase voltages are 2 kV. The magnitudes of the line voltages are Select one: O a. 3464.1 V O b. 6000 V Oc. 2000 V O d. 1154.7 Varrow_forwarda. Y-Connected b. В 100kW Source 0.9 LAG 80KVA 0.8 LAG Figure 1 80kW 0.85 LAGarrow_forwardSuppose you have a three-phase generator that provides 120 Vac per phase and works at a frequency of 60 Hz, this generator can be connected in both delta and star. Also consider the following 6 load impedances, which will be connected at the same time to the generator as follows: ZA, ZB and Zc are connected in star, while Zp, Zg and Zp are connected in delta. 10 ZA j 20 j30 Za j20 j30 j3Ω -j20 j3a -j2n Ze Zo •j20 j 30 j30. ZE -j20 Assume the generator is connected in delta, calculate the total power of the system and the total power factor.arrow_forward
- A star connected three phase alternator supplies power to a delta connected resistive load. The alternator has a line voltage of 480V. Each resistor of delta load has 8 ohm of resistance. Find the following values. Line voltage of the load (VL(load)) Phase voltage of the load (VP(load)) Phase current of the load (IP(load)) Line current delivered by the alternator (IL(alt)) Phase current of the alternator (IP(Alt)) Phase voltage of the alternator (VP(Alt)) True powerarrow_forwardSuppose you have a three-phase generator that provides 120 Vac per phase and works at a frequency of 60 Hz, this generator can be connected in both delta and star. Also consider the following 6 load impedances, which will be connected at the same time to the generator as follows: ZA, ZB and Zc are connected in star, while Zp, Zg and Zp are connected in delta. j20 j3n Za j20 ZA j30 j3n -j20 j 30 -j20 Zo -j20 ZE j30 -j2n j 3n. ZF Assume the generator is star-connected with neutral, calculate total system power, total power factor, and current in neutral.arrow_forwardSuppose you have a three-phase generator that provides 120 Vạc per phase and works at a frequency of 60 Hz, this generator can be connected in both delta and star. Also consider the following 6 load impedances, which will be connected at the same time to the generator as follows: ZA, ZB and Zc are connected in star, while Zp, Zg and Zp are connected in delta. j20 Za -j20 ZA j 30 j 30 -j20 j3a -j20 Zo -j20 ZE j30 -j20 j 30. Assume the generator is star connected with no neutral, calculate the total power of the system and the total power factor. mm marrow_forward
- A 415 V, 55 Hz 3-phase supply is connected to a 3- phase star connected balanced R-L load each of resistance 14 ohm and impedance 82 ohm. Find the value of inductance in each phase. 41.00 80.80 0.23 8.25arrow_forward1. What is the main direct cause of reactive power in AC system? A. Resistance of transmission lines B. Inductance and capacitance in the loads C. Ideal transformer connected in the system D. Power produced by generator 2. "Reactive power in a system is dissipated generally as thermal energy?" A. TRUE B. FALSE 3. Which of the following statements are correct for three phase circuit: A. Sum of all the three phase currents is zero in unbalanced network B. Total power transfer to load is constant with time C. Neutral conductor is same size in terms of material used as in single phase conductors D. Net apparent power consumed is equal to real powerarrow_forwardQuestion 4 The phase currents in a delta-connected three-phase load are as follows: between the red and yellow lines, 30 A at p.f. 0.707 leading; between the yellow and blue lines, 20 A at unity p.f.; between the blue and red lines, 25 A at p.f. 0.866 lagging. Calculate the line currents. Round your currents to one decimal place and your phase-angles to the nearest whole number.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License