An inventor proposes to make a “viscous timer” by placing a weighted cylinder inside a slightly larger cylinder containing viscous liquid, creating a narrow annular gap close to the wall. Analyze the flow field created when the apparatus is inverted and the mass begins to fall under gravity. Would this system make a satisfactory timer? If so, for what range of time intervals? What would be the effect of a temperature change on measured time?
Want to see the full answer?
Check out a sample textbook solutionChapter 8 Solutions
Fox and McDonald's Introduction to Fluid Mechanics
Additional Engineering Textbook Solutions
Mechanics of Materials (10th Edition)
Engineering Mechanics: Dynamics (14th Edition)
Fundamentals Of Thermodynamics
Introduction To Finite Element Analysis And Design
Degarmo's Materials And Processes In Manufacturing
Automotive Technology: Principles, Diagnosis, and Service (5th Edition)
- SOLVES TEP BY STEP DONT USE CHATGPT DONT USE AI 3. An oil of viscosity 1.8 cp and relative density 0.8 is contained in an open tank located above the application site. A 1.5-inch diameter pipe extends vertically from the bottom of the tank and is 5 m long. The oil level in the tank remains constant at 3 m above the bottom of the tank. In a case with friction the discharge speed can be obtained in the form of the following Equation. Calculate the flow rate of oil discharged per hour. Assume that the pipe is commercial steel (ε=0.05 mm). V= 2gh +f-arrow_forwardUse g=32.2 */sec2 (9.81 m/s2) and 60°F (16°C) water unless told to do otherwise.• Google schedule-40 pipe’s thickness at different nominal size to obtain the innerdiameter of the pipe for accurate determinaLon of flow velocity.• Must show your work to support your selecLon. Otherwise, no points will be given.Water flows through a schedule-40 pipe that changes gradually in diameter from 6 in (154mm) at point A to 18 in (429 mm) at point B. The volumetric flow rate is 5.0 *3/sec (130 L/s). The respecLve pressures at points A and B are 10 psia (70 kPa) and 7 psia (48.3 kPa). All lossesare insignificant. What are the direcLon of flow and velocity at point A? (A) 3.2 */sec (1 m/s); from A to B(B) 25 */sec (7.0 m/s); from A to B(C) 3.2 */sec (1 m/s); from B to A(D) 25 */sec (7.5 m/s); from A to Barrow_forwardA pitot-static probe, as depicted in Figure below, can be used to detect the velocity of a flowing liquid or air. To measure air velocity, the probe is linked to a manometer and put into a duct. Explain how a pitot-static velocity probe measures the velocity of air on an aeroplane and how it works.arrow_forward
- Problem 3: Leaking Tank Your engineering firm has been asked to determine whether the secondary clarifier (labeled "SECONDARY") downstream from the aeration basin (labeled "AERATION") is leaking at your local wastewater treatment plant. You conduct measurements over 45 minutes. During this time, you determine the average inflow rate Qin = 4.5 m³/min, the average outflow rate Qout = 4.0 m³/min, and the change in volume in the secondary clarifier is AV = 2.2 m³. You also determine that the fluid removed from the aeration basin is 90% water and 10% air by volume, since the fluid contains air bubbles. These bubbles rapidly dissipate in the secondary clarifier. PRETREATMENT OVERFLOW SECONDARY SLUDGE DIGESTION TRASH DRYER AERATION AIR PRIMARY DRY SLUDGE FINISHING ALICANTOY Is the secondary clarifier leaking, and if so, at what rate? [kg/min] SCUM METHANEarrow_forwardOn a single plot, plot three curves that show the relationship between the pressure generated by thepump as a function of flow rate of water at 20 °C through the three branches of the piping systemshown below. Delta P on y axis and flow rate on the x axis. The pressure range is 0 to 1 MPa. (Branches 1 and 3 are in the same plane; branch 2 is located 5 m above the other two branches. Pipe inner diameter: 0.0254 mPipe material: copperTypical mass flow rate of interest: 0.5 kg/sIgnore minor losses of tee's at points A and B and any features of branch 3Consider minor losses of two 90° elbows in branch 2arrow_forward3. A pump steadily circulates oil used for lubricating heavy machine tools. The volume flow rate and temperature of the oil are 300 gal/min and 104°F, respectively. At 104°F, the kinematic viscosity and the specific gravity of the oil are 2.15 x 10-3 ft² /s and 0.89, respectively. The pipe lengths are 25 ft for the 4-in diameter pipe and 75 ft for the 3-in diameter one. The Schedule-40 steel pipe has an average roughness element size of 0.0018 in. If all minor losses can be ignored, evaluate how much power (in a unit of horsepower) the pump delivers to the oil. 6 ft 22 ft Flow 15 ft Discharge line 3-in Schedule 40 Suction line 4-in Schedule 40 steel pipe steel pipe Pumparrow_forward
- ) where AP is the static The Hagen-Poiseuille equation for the laminar flow through a circular pipe is: AP pressure drop measured over some length of pipe, L. Use the Hagen-Poiseuille equation and the Darcy-Weisbach equation to derive an expression for the fanning friction factor, f, for laminar flow through a circular pipe where Re is the Reynolds number. Choose one answer from the list below: of= of O None of the above 32 Re 16 Re O f = 64 Re = o f = 32μLc 3 d² 8 Re O f = 16 Rearrow_forward6- Discussion: 1. Sketch a diagram for the experimental instrumentation and devices. 2. State any possible error source in the experiment. 3. State any suggestions to improve the experiment (visit youtube.com). 4. Compare the exact value with that obtained experimentally and estimate the error percentage. 5. What is mean by compressible and incompressible flow? 6. How does the specific heat of the air change with temperature? 7. Suggest another way to measure the air velocity by using a manometer?arrow_forwardCalculations involving retention time involve the following formula, T =, where V is volume and Q is flow rate. Often times, you will be required to calculate the volume of more than one tank and determine a rate of flow, given a total retention time. Tank 1 Tank 2 Let's assume that the total retention time for the entire system is 55 minutes, and we want to know the inlet flow, given the dimensions of tank 1 are : 14m x 10m x 3 m, and tank 2 are: 5m x 10m x 3 m. Calculate the inlet flow.arrow_forward
- As a process engineer, you are designing a new drinking water treatment plant using conventional treatment process including Two Rapid Mixers as follows: The design flow is 50 million gallons per day (MGD) (1 Gallon = 3.785 L, 1 m³ = 1000 L). The average temperature of water is 5°C with a dynamic viscosity, μ = 1.519 x 10-3 Pa.Sec In each rapid mixer with a square shape, detention time, e = 1 min, water depth H = 13 ft, and power input P = 1.5 kw (1 ft = 0.3048 m, 1 KW = 1,000 W) The equivalent diameter, TE for each rapid mixer is ________ m. TE || AIR 1) 4.1 2) 4.4 3) 4.6 4) 4.8 5) 0.4arrow_forwardA pitotstatic tube to be used in 2n airplane for on-flight measurement was calibrated on ground by using air of density 1.20 kg/m? . A measurement taken at an altitude of 3000 m where the ambient pressure and density were 70 kPa (abs) and 0.91 ke/m? respectively, indicated a velocity of 200 m/s by using the above ground level calibration. Estimate the true speed of the airplane [Take k = 1.4 and R = 287 (kg K)l.arrow_forwardBE132/EngD215 Systems Accounting & Modeling II Include the "Known, Find, Given, Strategy, Analysis" for these problems. Problem 7.1 Oil and water flow at constant rates into the device shown below. The oil (poil = 56.8 lbm/ft³) forms into oil droplets that rise upward due to their lower specific gravity and are trapped by a baffle, creating an oil layer with a cross-sectional area, A, of 10 ft². Water (Pwater = 62.2 lbm/ft³) flows out of the device at a rate of 20 lbm/hr. The water level in the device remains constant, but the height, h, of the oil layer increases at the rate of 1 inch per day. What are the mass flow rates of oil and water into the device in lbm/hr? You may assume that the water and oil do not mix. water h oil layer oil droplets oil A = 10 ft² water baffle baffle HW Set 7 waterarrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY