Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 4, Problem 4.6.1P
To determine
(a)
A W14 section of A992 steel using column load tables.
To determine
(b)
A W16 section of A592 steel using trial and error method.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
ASSIGNMENT #5 BIAXIAL BENDING
Problem: Check the beam shown for
compliance with the NSCP Specification.
Lateral support is provided only at the ends,
and A992 steel is used, F, = 345 mPa.
The 90 kN service loads are 30% dead load
and 70% live load.
a. Use LRFD
b.
Use ASD
d tw by ty 1x(106) S(10³)
mm mm mm
mm³
mm
mmª
W410x100 415 10 260 16.9 398
1920
SECTION
Tx
mm
177
1m
90 kN
90 KN
1.5m
W410x100
I
Loaded Section
Ly(106) Sy(10³) Ty
mmª mm³
mm
49.5
381
62.4
1m
Zx(10³) Zy(10³)
mm³ mm³
2130
581
SITUATION 2
Determine the safe service load W
permitted for this beam-column that
is not part of a frame system.
Assume ASTM A992 (Fy = 350 MPa;
Fu = 450 MPa) as material. Use LRFD
specifications.
Servise koada
P= 30 kips dead load
80 kips live koad
Assume
hinged
for both
principal
10- 0
directions
W- 20 dead load
8OG live load
10-o
Fined for both
principal
directions
Type your final answer/s in the text
box provided below.
HOMEWORK-1
3m
IF
For the truss shown in the figure;
Design members 1-2 and 2-3 assuming that out of plane deflections are restrained and Ner>>10,
i.e. global buckling is not the critical failure mode and therefore linear static analysis is
sufficient.
P.S. Use square rectangular hollow sections in Grade 355 steel. You will have to find the related section
tables from the internet. Do not forget to refer to the related EN1993-1-1 tables and equations.
Later, you will design the connections (the weld lengths, etc.) and the supports for this problem.
Chapter 4 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 4 - Prob. 4.3.1PCh. 4 - Prob. 4.3.2PCh. 4 - Prob. 4.3.3PCh. 4 - Prob. 4.3.4PCh. 4 - Prob. 4.3.5PCh. 4 - Prob. 4.3.6PCh. 4 - Prob. 4.3.7PCh. 4 - Prob. 4.3.8PCh. 4 - Prob. 4.4.1PCh. 4 - Prob. 4.4.2P
Ch. 4 - Prob. 4.6.1PCh. 4 - Prob. 4.6.2PCh. 4 - Prob. 4.6.3PCh. 4 - Prob. 4.6.4PCh. 4 - Prob. 4.6.5PCh. 4 - Prob. 4.6.6PCh. 4 - Prob. 4.6.7PCh. 4 - Prob. 4.6.8PCh. 4 - Prob. 4.6.9PCh. 4 - Prob. 4.7.1PCh. 4 - Prob. 4.7.2PCh. 4 - Prob. 4.7.3PCh. 4 - Use A992 steel and select a W14 shape for an...Ch. 4 - Prob. 4.7.5PCh. 4 - Prob. 4.7.6PCh. 4 - Prob. 4.7.7PCh. 4 - The frame shown in Figure P4.7-8 is unbraced, and...Ch. 4 - Prob. 4.7.9PCh. 4 - Prob. 4.7.10PCh. 4 - Prob. 4.7.11PCh. 4 - Prob. 4.7.12PCh. 4 - Prob. 4.7.13PCh. 4 - Prob. 4.7.14PCh. 4 - Prob. 4.8.1PCh. 4 - Prob. 4.8.2PCh. 4 - Prob. 4.8.3PCh. 4 - Prob. 4.8.4PCh. 4 - Prob. 4.9.1PCh. 4 - Prob. 4.9.2PCh. 4 - Prob. 4.9.3PCh. 4 - Prob. 4.9.4PCh. 4 - Prob. 4.9.5PCh. 4 - Prob. 4.9.6PCh. 4 - Prob. 4.9.7PCh. 4 - Prob. 4.9.8PCh. 4 - Prob. 4.9.9PCh. 4 - Prob. 4.9.10PCh. 4 - Prob. 4.9.11PCh. 4 - Prob. 4.9.12P
Knowledge Booster
Similar questions
- If the beam in Problem 5.5-9 i5 braced at A, B, and C, compute for the unbr Cb aced length AC (same as Cb for unbraced length CB). Do not include the beam weight in the loading. a. Use the unfactored service loads. b. Use factored loads.arrow_forwardA beam must be designed to the following specifications: Span length = 35 ft Beam spacing = 10 ft 2-in. deck with 3 in. of lightweight concrete fill (wc=115 pcf) for a total depth of t=5 in. Total weight of deck and slab = 51 psf Construction load = 20 psf Partition load = 20 psf Miscellaneous dead load = 10 psf Live load = 80 psf Fy=50 ksi, fc=4 ksi Assume continuous lateral support and use LRFD. a. Design a noncomposite beam. Compute the total deflection (there is no limit to be checked). b. Design a composite beam and specify the size and number of stud anchors required. Assume one stud at each beam location. Compute the maximum total deflection as follows: 1. Use the transformed section. 2. Use the lower-bound moment of inertia.arrow_forwardThe beam shown in Figure is a two-span beam with a pin (hinge) in the center of the left span,making the beam statically determinate. There is continuous lateral support. The concentratedloads are service live loads. Determine whether a W12 × 79 of A992 steel is adequate.a. Use LRFD.b. Use ASD.arrow_forward
- The below figure represents a section of a pre- stressed beam. For a no-tension design where a is the permissible stress in concrete, the total moment carrying capacity is (a) (c) d/2 bd² 6 d/2 bd²oc 3 -b- (b) (d) bd² oc 4 bd²a 12arrow_forward1. A steel column 10 m long is fabricated from a cover plate and C section arranged as shown. Determine the safe compressive load. Fy = 248 MPa, E= 200 GPa. Use AISC/NSCP Specs. 450 mm -cover plate 'I 12 mm y2 IP d2 10 m C 310 x 37 A = 4720 mm? d = 305 mm bf = 77 mm tf = 12.7 mm tw = 9.8 mm C 310 X 37 a) Both ends of column are fixed b) Both ends of column are hinged c) One end fixed, the other end hinged Use design values of k. tw d=305- Ix = 59.9x10° mm ly = 1.85x10° mm x = 17.1 mm x=17.1arrow_forwardA built-up section was made using PL414x12mm thk plates as shown in the figure below. It is pinned at both ends with additional support against weak axis at middle point. Assume A50 steel. PL414x12 DO Section W16x67 L x-axis a) Calculate moment of inertia at both axes in mm*. b) Determine the design compressive strength in kN if L-3m. c) Find the design compressive strength in kN if L=18m. Elevation y-axisarrow_forward
- Check the beam shown in Figure P5.15-4 for compliance with the AISC Specifica- tion. Lateral support is provided only at the ends, and A992 steel is used. The 20-kip service loads are 30% dead load and 70% live load. a. Use LRFD. b. Use ASD. 20k |——3² — 20k FIGURE P5.15-4 W16 x 57 -3'— 3arrow_forward4.3-4 Determine the available strength of the compression member shown in Figure P4.3-4. in each of the following ways: a. Use AISC Equation E3-2 or E3-3. Compute both the design strength for LRFD and the allowable strength for ASD. 15 HSS 10x6x ASTM A500, Grade B steel (Fy=46 ksi) 2/3arrow_forwardThe beam under the Live and Dead loads is shown below. The steel class is $235. Lig L1 L2 a.) Evaluate the slenderness of the web and flange. b.) Calculate the Cb value based on the loads. c.) Calculate the bending moment capacity of the beam... d.) Is the beam cross-section enough for the given loads. L3arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning