Question
Chapter 4, Problem 4.7.14P
To determine
(a)
Use A992 steel and selecting a
To determine
(b)
Use A992 steel and selecting a
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Q2) The members of the truss structure shown below is plain concrete. The compressive
strength of the concrete is 25 MPa. Compute the maximum load P that can be carried by
the structure. (Cross section of each member of the truss is 200 x 200 mm and don't use
material factors and do not consider slenderness) Comment on your results briefly.
P
A&
2m
SC
2 m
1380
2m
D
determine the member stresses of the truss
shown. indicate if the stress in the member is in
tension or compression. present complete and
neat solutions. p1-30kN W-25kN/m P2=51kN
AH
Av
Im
P₂
Im
P₂
Im
P₂
Im
Av
W
1.6m
1.20 Calculate the truss's smallest allowable cross-sectional areas of members CE, BE,
and EF. In tension, the working stresses are 20 ksi, while in compression, they are 14
ksi. (In compression, the working stress is lower to lessen the risk of buckling.)
15Kips
15Kips
4ft
Vc 4ft
VD
E
9ft
G.
Chapter 4 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 4 - Prob. 4.3.1PCh. 4 - Prob. 4.3.2PCh. 4 - Prob. 4.3.3PCh. 4 - Prob. 4.3.4PCh. 4 - Prob. 4.3.5PCh. 4 - Prob. 4.3.6PCh. 4 - Prob. 4.3.7PCh. 4 - Prob. 4.3.8PCh. 4 - Prob. 4.4.1PCh. 4 - Prob. 4.4.2P
Ch. 4 - Prob. 4.6.1PCh. 4 - Prob. 4.6.2PCh. 4 - Prob. 4.6.3PCh. 4 - Prob. 4.6.4PCh. 4 - Prob. 4.6.5PCh. 4 - Prob. 4.6.6PCh. 4 - Prob. 4.6.7PCh. 4 - Prob. 4.6.8PCh. 4 - Prob. 4.6.9PCh. 4 - Prob. 4.7.1PCh. 4 - Prob. 4.7.2PCh. 4 - Prob. 4.7.3PCh. 4 - Use A992 steel and select a W14 shape for an...Ch. 4 - Prob. 4.7.5PCh. 4 - Prob. 4.7.6PCh. 4 - Prob. 4.7.7PCh. 4 - The frame shown in Figure P4.7-8 is unbraced, and...Ch. 4 - Prob. 4.7.9PCh. 4 - Prob. 4.7.10PCh. 4 - Prob. 4.7.11PCh. 4 - Prob. 4.7.12PCh. 4 - Prob. 4.7.13PCh. 4 - Prob. 4.7.14PCh. 4 - Prob. 4.8.1PCh. 4 - Prob. 4.8.2PCh. 4 - Prob. 4.8.3PCh. 4 - Prob. 4.8.4PCh. 4 - Prob. 4.9.1PCh. 4 - Prob. 4.9.2PCh. 4 - Prob. 4.9.3PCh. 4 - Prob. 4.9.4PCh. 4 - Prob. 4.9.5PCh. 4 - Prob. 4.9.6PCh. 4 - Prob. 4.9.7PCh. 4 - Prob. 4.9.8PCh. 4 - Prob. 4.9.9PCh. 4 - Prob. 4.9.10PCh. 4 - Prob. 4.9.11PCh. 4 - Prob. 4.9.12P
Knowledge Booster
Similar questions
- A plate girder must be designed for the conditions shown in Figure P10.7-4. The given loads are factored, and the uniformly distributed load includes a conservative estimate of the girder weight. Lateral support is provided at the ands and at the load points. Use LRFD for that following: a. Select the, flange and web dimensions so that intermediate stiffeners will he required. Use Fy=50 ksi and a total depth of 50 inches. Bearing stiffeners will be used at the ends and at the load points, but do not proportion them. b. Determine the locations of the intermediate stiffeners, but do not proportion them.arrow_forwardThe rigid frame shown in Figure is unbraced in the plane of the frame. In the direction perpendicular to the frame, the frame is braced at the joints. The connections at these points of bracing are simple (moment-free) connections. Roof girders are W14 x 30, and floor girders are W16 x 36. Member BC is a W10 x 45. Use A992 steel and select a W-shape for AB. Assume that the controlling load combination causes no moment in AB. The service dead load is 25 kips and the service live load is 75 kips. a. Use LRFD. b. Use ASDarrow_forwardDetermine the kind of amount of stress in members of the truss shown by the method of joints or method of section P1 = 12KN P2 = 20KN P3 = 30KN P4 = 40KN P5 = 50KN U 2 U 5 Lo L1 L, L3 L4 L5 P P 5 P 1 P 2 P3 Span = 6 m at 1 m e ach pan el He ight of tru ss = 2 marrow_forward
- 3) Determine the Force in each member of the truss shown in the Figure. (Use the Method of Joints.) D B gl 12' H E 300lb 300lb goolb 9' 9'arrow_forward2. Find the force acting in Bar AC, CE, DE, DF & FH of the Truss as shown in the below figure. B F E 1000 ib 1000 b 1000 b A -12 12 -12- -12 RA RBarrow_forwardAnswers: AB = kN E AH = kN Determine the force in each member of the loaded truss. All triangles are 3-4-5. Enter a the member is in tension, negative if in compression. BC - kN C 34kN kN BG E 34 kN BH - kN 15 kN BI = kN D B kN kN A E DE kN H G F DF = kN - 4 panels at 8 m- DG = kN DI kN EF = kN FG - kN GH = kNarrow_forward
- Q4. [TYPE C] A loaded K-truss is supported by a roller at A and a pin at G as shown. Determine the force in members LM, MK, KC, and BC of the K-truss, and state whether they are in tension (T) or compression (C), or whether it is a zero-force member (ZFM). 500 lb 2 ft 2 ft A © 2023 Shanbe Huang 3 ft B K 3 ft M N C 3 ft D 3 ft P 3 ft H E F 3 ft Garrow_forwardWhich set of elements contains Zero Force Member? I s/2 K- F, s/2 F I D F A S. F2 F1 AB - BD - DE - EG- G DC - CE - HG - JI- HJarrow_forwardW 14 x 142 is used as a column having a length of 9 m. long. It is hinged at the r end and fixed at the lower end but there is a lateral bracing perpendicular to minor axis of the W section at a point 6 m. above the bottom support. It is assumed to be pinned connected at the bracing point. Using A 36 steel Fy 248 MPa the NSCP Specifications. E= 200000 MPa. Properties of W 14 x 142 A-26967.69 mm2 d=374.65 mm bf=393.70 mm tf-27.00 mm tw 17.27 mm Ix 695.11 x 106 mm4 Iy = 274.71 x 106 mm4 rx = 160.53 mm ry 100.84 mm 221 Assume: Kx=0.80 for 9 m. length KY 1.9 for the length on the upper support KY-0.80 for the length on the bottom support CIVIL ENGINEERING- STEEL DENON a) Compute the slenderness ratio along y-axis. b) Compute the slenderness ratio along x-axis. c) Compute the safe axial loadarrow_forward
- The member shown in Figure has lateral support at points A, B, and C. Bending is about the strong axis. The loads are service loads, and the uniform load includes the weight of the member. A992 steel is used. Is the member adequate? a. Use LRFD. b. Use ASD.arrow_forwardA. A truss member is made with a pair of 4"x 3" x 3/8" angles with the long legs back to back. The angles are 36 ksi steel and are attached at the connection by a 3/8 in. plate running between the angles. The unbraced length is 12 feet and consider both ends fixed. What is the allowable axial load in compression? In tension? How does the compression capacity change if I connect them with a %" plate in between? Does it change tension capacity? (a) 12 C. A 28 foot column is braced top and bottom about the X-X axis and has K bracing as shown on the Y-Y axis only. It is built of A36 steel and is a W12 x 30 section. Can it support an axial load of 165 kips? State its actual capacity.arrow_forward