Conditions in one zone of a dual-duct conditioning system are to be maintained at 75 F (24 C) and 50 percent relative humidity (RH). The cold deck air is at 52 F (11 C) and 90 percent RH, while the hot deck air is outdoor air at 90 F (32 C) and 20 percent RH. The sensible heat factor for the zone is 0.65. Assume sea-level pressure. In what proportion must the warm and cold air be mixed to satisfy the space condition? If the total zone load is 50 tons (176 kW), what is the total volume flow rate of air supplied to the zone? Sketch the states and processes on a psychrometric chart. Use (a) English units and (b) SI units.
Want to see the full answer?
Check out a sample textbook solutionChapter 3 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Additional Engineering Textbook Solutions
Problem Solving with C++ (10th Edition)
Starting Out with C++ from Control Structures to Objects (9th Edition)
Introduction To Programming Using Visual Basic (11th Edition)
Electric Circuits. (11th Edition)
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
Web Development and Design Foundations with HTML5 (8th Edition)
- Thermo Fluid help needed air conditionerarrow_forwardThe design condition for a space is 77oF db and 50% relative humidity with 55oF db supply air at 90% relative humidity. A 50-ton, constant-volume space air- conditioning system uses face and bypass and water temperature control. Outdoor air is supplied at 95oF db, 60% relative humidity with a ratio of 1 lbm to 5 lbm re-circulated air. A part-load condition exists where the total space load is decreased by 50% and the SHF is increased to 90%. The outdoor air condition changes to 85oF db and 70% relative humidity. Assume sea-level conditions. a) At full – load conditions:a. Show all the processes on a psychrometric chart.b. Determine the temperature must the air be supplied to the space at fullload conditions.c. Determine the apparatus dew point temperature at full load conditions. b)At part – load conditions:a. Show all the processes on a psychrometric chart.b. Determine the temperature must the air be supplied to the space at partload conditions.c. Determine the apparatus dew point…arrow_forwardRequired information NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part. An air-conditioning system operates at a total pressure of 1 atm and consists of a heating section and a humidifier that supplies wet steam (saturated water vapor) at 100°C. Air enters the heating section at 10°C and 70 percent relative humidity at a rate of 32 m /min, and it leaves the humidifying section at 20°C and 60 percent relative humidity. Use data from the tables. Sat. vapor 100°C Heating coils Humidifier 10°C Air 20°C 70% 60% ymYmin P=1 atm Determine the temperature and relative humidity of air when leaves the heating section. The temperature is °C. The relative humidity is %.arrow_forward
- Air Conditioning Thermo Fluidarrow_forwardIf the dry-bulb temperature of the air surrounding a typical cooling is 90 degrees Fahrenheit and the relative humidity of the air is 50%, the cooling tower should be able to cool the water in the tower to a temperature of: A. 82 degree Fahrenheit B. 75 degree Fahrenheit C. 89 degree Fahrenheit D. 95 degree Fahrenheitarrow_forwardPick the right combination of True Statements. 1. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP decreases. 2. As the by-pass factor (BPF) of the cooling coil increases, temperature difference between air at the outlet of the coil and coil ADP increases. 3. During cooling and humidification process, the enthalpy of air may increase, decrease or remain constant depending upon the temperature of the wet surface. 4. During sensible cooling of air, dry bulb temperature decreases but wet bulb temperature remains constant 5. The sensible heat factor for a sensible heating process is 1.0arrow_forward
- notes : 1- Solve in British International Units, not in American units 2- Use operations and psychrometry in the solution as wellarrow_forwardAn air-conditioning system operates at a total pressure of 1 atm and consists of a heating section and a humidifier that supplies wet steam (saturated water vapor) at 100 degrees celsius. Air enters the heating section at 10 degrees celsius and 70 percent relative humidity at a rate of 35 m^3/min, and it leaves the humidifying section at 20 degree celcius and 60 percent relative humidity. Heating coils Loooooooo 10°C 70% 35 m³/min AIR P = 1 atm Sat. vapor 100°C Humidifier € 20°C 60% a. Humidity ratio at inlet b. Relative humidity at the exit c. Humidity ratio at exit d. Rate at which water is added to humidifying sectionarrow_forwardplease solve in 5o mins i will give you positive feedback. i need handwritten solution on pagesarrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY