Conditions in one zone of a dual-duct conditioning system are to be maintained at 75 F (24 C) and 50 percent relative humidity (RH). The cold deck air is at 52 F (11 C) and 90 percent RH, while the hot deck air is outdoor air at 90 F (32 C) and 20 percent RH. The sensible heat factor for the zone is 0.65. Assume sea-level pressure. In what proportion must the warm and cold air be mixed to satisfy the space condition? If the total zone load is 50 tons (176 kW), what is the total volume flow rate of air supplied to the zone? Sketch the states and processes on a psychrometric chart. Use (a) English units and (b) SI units.
Want to see the full answer?
Check out a sample textbook solutionChapter 3 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Additional Engineering Textbook Solutions
Manufacturing Engineering & Technology
Fundamentals Of Thermodynamics
Introduction to Heat Transfer
Thinking Like an Engineer: An Active Learning Approach (3rd Edition)
Fox and McDonald's Introduction to Fluid Mechanics
Degarmo's Materials And Processes In Manufacturing
- The design condition for a space is 77oF db and 50% relative humidity with 55oF db supply air at 90% relative humidity. A 50-ton, constant-volume space air- conditioning system uses face and bypass and water temperature control. Outdoor air is supplied at 95oF db, 60% relative humidity with a ratio of 1 lbm to 5 lbm re-circulated air. A part-load condition exists where the total space load is decreased by 50% and the SHF is increased to 90%. The outdoor air condition changes to 85oF db and 70% relative humidity. Assume sea-level conditions. a) At full – load conditions:a. Show all the processes on a psychrometric chart.b. Determine the temperature must the air be supplied to the space at fullload conditions.c. Determine the apparatus dew point temperature at full load conditions. b)At part – load conditions:a. Show all the processes on a psychrometric chart.b. Determine the temperature must the air be supplied to the space at partload conditions.c. Determine the apparatus dew point…arrow_forwardRequired information NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part. An air-conditioning system operates at a total pressure of 1 atm and consists of a heating section and a humidifier that supplies wet steam (saturated water vapor) at 100°C. Air enters the heating section at 10°C and 70 percent relative humidity at a rate of 32 m /min, and it leaves the humidifying section at 20°C and 60 percent relative humidity. Use data from the tables. Sat. vapor 100°C Heating coils Humidifier 10°C Air 20°C 70% 60% ymYmin P=1 atm Determine the temperature and relative humidity of air when leaves the heating section. The temperature is °C. The relative humidity is %.arrow_forwardIs it possible that during sensible cooling process the condition of air reaches a relative humidity of more than 100%.arrow_forward
- If the dry-bulb temperature of the air surrounding a typical cooling is 90 degrees Fahrenheit and the relative humidity of the air is 50%, the cooling tower should be able to cool the water in the tower to a temperature of: A. 82 degree Fahrenheit B. 75 degree Fahrenheit C. 89 degree Fahrenheit D. 95 degree Fahrenheitarrow_forwardWhat is the relative humidity when the dry-bulb temperature is 16 % and the wet-bulb temperature is 14 % 80% 70% 60% 90%arrow_forwardUsing a psychometric diagram, describe the heating and humidification process from the following data. Initially the air was at dry bulb temperature (DBT) 35 ° C and RH 35%. air preheated to DBT 85 ° C. The heated air is then flowed through a humidifier to increase the RH to 25%. for this process, count, a. change in absolute humidity of air from initial to final conditions = ..... (kg water / kg air) b. change in air enthalpy from initial to final conditions = ..... (kj / kg air)arrow_forward
- In an air sample with a dry-bulb temperature of 28°C and a wet-bulb temperature of 22°C what is the (relative humidity)?arrow_forwardAn air-conditioning system operates at a total pressure of 1 atm and consists of a heating section and a humidifier that supplies wet steam (saturated water vapor) at 100 degrees celsius. Air enters the heating section at 10 degrees celsius and 70 percent relative humidity at a rate of 35 m^3/min, and it leaves the humidifying section at 20 degree celcius and 60 percent relative humidity. Heating coils Loooooooo 10°C 70% 35 m³/min AIR P = 1 atm Sat. vapor 100°C Humidifier € 20°C 60% a. Humidity ratio at inlet b. Relative humidity at the exit c. Humidity ratio at exit d. Rate at which water is added to humidifying sectionarrow_forwardHUMIDIFIER: MASS BALANCE On a hot summer day, the air is at 30.6 ° C and 80% relative humidity. The air conditioning in a building supplies 30 m3 / min of air at 13 ° C to keep the air inside the building at an average temperature of 24 ° C and 40% relative humidity. If the ventilation switch of the air conditioner is “open”, the air from outside enters the unit as shown in the drawing (I): The air conditioner cools the air to a temperature low enough to condense the required amount of water and reheat it to 13 ° C (unsaturated current), at which point it has the same absolute humidity as the air in the building. Calculate: a. the speed at which condenses water (kg / min) b. the temperature at which the air must be cooled to condense water at this rate. Do the calculations without using the psychrometric chart (although 1 atm of current pressure can be assumed). If the ventilation switch is closed, as normal, the air from inside the building would be recirculated in the air…arrow_forward
- Is it possible that during sensible heating process the condition of air reaches a relative humidity of 0% ?arrow_forwardA space is to be maintained at 75 F db and 40% relative humidity. The total heat gain to the space is 62,000 Btu/hr with a SHF of 0.8. The outdoor air requirement is 500 cfm. The outdoor air has a temperature of 90 F and 50% relative humidity. Assume that the supply air has a temperature of 50 F db. Determine the following: a. Quantity of supplied air b. Capacity of the cooling coil c. Rate of moisture removal from the dehumidification elementarrow_forwardProblem 2: An air-conditioning system operates at a total pressure of 1 atm and consists of a heating section and a humidifier that supplies wet steam (saturated water vapor) at 100 degrees celsius. Air enters the heating section at 10 degrees celsius and 70 percent relative humidity at a rate of 35 m^3/min, and it leaves the humidifying section at 20 degree celcius and 60 percent relative humidity. Heating coils Leeeeeeee 10°℃ 70% 35 m³/min AIR P = 1 atm Sat. vapor 100°C Humidifier 20°C 60% a. Humidity ratio at inlet b. Relative humidity at the exit c. Humidity ratio at exit d. Rate at which water is added to humidifying sectionarrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY