Chapter 3, Problem 3.32P
Air enters a refrigeration coil at 90 Fdb and 75 Fwb at a rate of 1400 cfm. The apparatus dew point temperature of the coil is 55 F. If 5 tons of refrigeration are produced, what is the dry bulb temperature of the air leaving the coil. Assume sea-level pressure.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A reheat cycle with two stages of reheating is executed with steam expanding
initially from 25 MPa and 600 °C. The two reheater pressures are 4 MPa and 1
MPa, and the steam leaves each reheater at 600 °C. Condensation occurs at
40°C.
What is hi in kJ/kg?
Required information
Problem 08.036E - DEPENDENT MULTI-PART PROBLEM - ASSIGN ALL PARTS - Refrigerant Constant
Volume System
NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part.
A 17-ft3 rigid tank contains refrigerant-134a at 30 psia and 55 percent quality. Heat is transferred now to the refrigerant
from a source at 120°F until the pressure rises to 50 psia. Assume the surroundings to be at 75°F.
Problem 08.036E.b - Exergy Destroyed for Refrigerant Constant Volume System
Determine the exergy destroyed during this process.
The exergy destroyed during this process is
Btu.
Is aircon-ditioner an example of thermodynamic system inside the house? Is it an open system, closed system or isolated system? Explain why.
Chapter 3 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Ch. 3 - A space is at a temperature of 75 F (24 C), and...Ch. 3 - Determine the humidity ratio, enthalpy, and...Ch. 3 - Suppose the air of Problem 3-2 is at a pressure...Ch. 3 - What is the enthalpy of moist air at 70 F (20 C)...Ch. 3 - The inside surface temperature of a window in a...Ch. 3 - What is the mass flow rate of dry air flowing at a...Ch. 3 - Determine the dew point of moist air at 80 F (27...Ch. 3 - A room is to be maintained at 72 F (22 C) db. It...Ch. 3 - Air is cooled from 80 F db and 67 F wb until it is...Ch. 3 - Conditions in a room are measured to be 80 F db...
Ch. 3 - The environmental conditions in a room are to be...Ch. 3 - Air enters a cooling coil at the rate of 5000 cfm...Ch. 3 - Air flowing in a duct has dry and wet bulb...Ch. 3 - Air is humidified with the dry bulb temperature...Ch. 3 - Air at 38 C db and 20 C wb is humidified...Ch. 3 - Two thousand cfm (1.0 m3/s) of air at an initial...Ch. 3 - Air at 40 F (5 C) db and 35 F (2 C) wb is mixed...Ch. 3 - Rework Problem 3-25, using Chart 1a, with the...Ch. 3 - The design cooling load for a zone in a building...Ch. 3 - Assume that the air in Problem 3-22 is supplied to...Ch. 3 - The sensible heat loss from a space is 500,000...Ch. 3 - Air enters a refrigeration coil at 90 Fdb and 75...Ch. 3 - A building has a total heating load of 200,000...Ch. 3 - Reconsider Problem 3-36 for an elevation of 5000...Ch. 3 - The system of Problem 3-34 has a supply air fan...Ch. 3 - An evaporative cooling system is to be used to...Ch. 3 - A cooling system is being designed for use at high...Ch. 3 - Consider a space heating system designed as shown...Ch. 3 - A variable-air-volume VAV cooling system is a type...Ch. 3 - Rework Problem 3-43 for an elevation of 5000 feet...Ch. 3 - The design condition for a space is 77 F (25 C) db...Ch. 3 - Rework Problem 3-45 for an elevation of 5000 feet...Ch. 3 - It is necessary to cool and dehumidify air from 80...Ch. 3 - Conditions in one zone of a dual-duct conditioning...Ch. 3 - Rework Problem 3-48 for an elevation of 5000 ft...Ch. 3 - A water coil in Problem 3-48 cools return air to...Ch. 3 - A multizone air handler provides air to several...Ch. 3 - Under normal operating conditions a zone has a...Ch. 3 - An interior zone of a large building is designed...Ch. 3 - Outdoor air is mixed with room return air to...Ch. 3 - Consider an enclosed swimming pool. The pool area...Ch. 3 - One particular zone served by a multizone air...Ch. 3 - A research building requires 100 percent outdoor...Ch. 3 - A space requires cooling in the amount of 120,000...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
In each case, construct the parallelogram law to show FR = F1 + F2. Then establish the triangle rule, where FR ...
Statics and Mechanics of Materials (5th Edition)
What difficulties can result from not keeping clamping forces low in designing jigs and fixtures?
DeGarmo's Materials and Processes in Manufacturing
The overhang beam is subjected to the uniform distributed load having an intensity of w=50 kN/m. Determine the ...
Mechanics of Materials
The moments of inertia Iu,Iv and the product of inertia Iuv for the rectangular area.
Engineering Mechanics: Statics & Dynamics (14th Edition)
Determine the maximum normal stress developed in the bar when it is subjected to a tension of P = 8kN.
Mechanics of Materials (10th Edition)
Find the missing properties among (P,T,v,u,h) together with x, if applicable, and give the phase of the substan...
Fundamentals Of Thermodynamics
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A barometric condenser serves a steam turbine which is exhausting 2720 kg ofsteam per hour at a pressure of 0.007MPa and having a quality of 90%.a. Determine the gpm of 15.56°C cooling water needed.b. Determine the temperature of cooling water needed.arrow_forwardAn ammonia refrigeration compressor takes its suction from the evaporator, at a temperature of-200F and a quality of 95%. The compressor discharges at a pressure of 100 psi, liquid ammonia leaves the condenser at 500F.(a)Determine the heat absorbed by the evaporator in kJ/kg. (b)Determine the heat rejected to the condenser in kJ/kg. (c)Determine the COP. (d)Determine the horsepower per ton of refrigeration. (e)Determine the quality of refrigerant upon entering to the evaporatorarrow_forwardSheet 5 Q1/ In a condenser the vacuum of 71 cm of Hg is maintained with barometer reading of 76 cm in Hg. Temperature in condenser is 35°C while hot well is at temperature of 30°C. The cooling water is circulated at the rate of 800 kg/min and condensate is available at 25 kg/min. The temperature of cooling water at inlet and outlet are 15°C and 25°C. Determine the mass of air in kg/m³ of condenser volume, dryness fraction of steam entering condenser and vacuum efficiency. Take mercury density as 0.0135951 kg/cm³, g = 9.81 m/s².arrow_forward
- A reheat cycle with two stages of reheating is executed with steam expanding initially from 25 MPa and 600 °C. The two reheater pressures are 4 MPa and 1 MPa, and the steam leaves each reheater at 600 °C. Condensation occurs at 40°C. For 1 kg/s of steam, what is QA in kW? Remember, 1. For values taken from the steam tables: Use them as is, do not round off. 2. For values obtained by interpolation and final answers obtained by solving, use FOUR (4) decimal places. 3. Use the steam tables providedarrow_forwardFill in the blanks: Brine enters a circulating brine cooler at the rate of 1000 Lpm. at -8°C and leaves at -18°C. Specific heat of brine is 1.072 KJ/kg-K and specific gravity of 1.12. Determine the tons of refrigeration.arrow_forwardThe catalogue for a refrigerant 22, four-cylinder, hermetic compressor operating at 29 r/s. a condensing temperature of 40 °C and an evaporating temperature of -4 °C shows a refrigeration capacity of 96.4 kW. At this operating points the motor (whose efficiency is 90 percent) draws 28.9 kW. The bore of the cylinders is 87 mm and the piston stroke is 70 mm. The performance data are based on 8 °C of subcooling of the liquid leaving the condenser. Compute 3.1 the actual volumetric efficiency and 3.2 the compression efficiency.arrow_forward
- Properties of Carbon Dioxide: h@ 220 KPa and -5°C = 350 KJ/kg h@ 25°C = 223.65 KJ/kg h.@ 22°C = 220.75 KJ/kg h. @ 220 KPa = 347.13 KJ/kg %3D %3D %3D Saturated Vapor Carbon Dioxide refrigerant at 220 KPa leaves the evaporator and enters the compressor at -5 °C. The refrigerant leaves the condenser as saturate liquid at 25 °C and enters the expansion valve at 22 °C. Heat rejected from the condenser amount 90 KW. The work to the compressor is 60 KJ/kg while the heat lost from the compressor is 5 KJ/kg. If 2.5 KJ/kg of heat are lost in the piping between the compressor and condenser. Solve for the mass flowrate of the refrigerant in kg/hr.arrow_forwardProblem 2 – Control volume compressor analysis An adiabatic compressor used in a refrigeration system compresses R-134a at P1 equal to 180 kPa and superheated by 2.73°C to a pressure P2 equal to 600 kPa. Please answer the following questions. a. For an adiabatic and reversible compression, determine the final temperature of the compression, in °C. Represent the process on a T-s diagram including the relevant isobars. b. For the adiabatic and reversible compression determine the compression work. Would you consider your result to be equal to the minimum work per unit mass that a R-134a compressor will require to operate between P1 and P2? c. Now you wish to compare the adiabatic and reversible compressor against an actual compressor operating between the same pressures and inlet conditions for which the temperature at the exit of the compressor is equal to 50°C. Determine the enthalpy at the exit of the actual compressor and the work per unit mass needed for the…arrow_forwardSaturated steam at 40∘C is to be cooled to saturated liquid in a condenser. The mass flow rate of the steam is 17.3 kg/s . Assume no pressure loss. a)Determine the rate of heat transfer. Q = ? MWarrow_forward
- Steam is delivered to turbine at 5.4 MPa and 600 degree C. Before condensation at 31 degree C, steam is extracted for feed water heating at 0.6 MPa. The turbine exhaust is 60 degree C. the required values of some state point properties are tabulated below. 7. Determine the quality of steam at the condenser inlet.arrow_forwardProblem (8.1) The steam at 100 bar and 500°C is supplied to a steam turbine of 30 MW capacity. The vacuum maintained in the condenser is 71 cm of Hg when the barometer reads 76 cm of Hg. The steam coming out of the turbine is condensed in a surface condenser using river water for cooling. The rise in temperature of the cooling water is limited to 10°C. The temperature of the water at the inlet of the condenser is 20°C. The condensate comes out of condenser as saturated liquid. Find (a) the mass of steam supplied to the turbine per hour, (b) Capacity of the pump to circulate water, (c) the heat transfer area of the condenser if the overall heat transfer coefficient is 400 W/m²°C.arrow_forwardProblem (8.1) The steam at 100 bar and 500°C is supplied to a steam turbine of 30 MW capacity. The vacuum maintained in the condenser is 71 cm of Hg when the barometer reads 76 cm of Hg. The steam coming out of the turbine is condensed in a surface condenser using river water for cooling. The rise in temperature of the cooling water is limited to 10°C. The temperature of the water at the inlet of the condenser is 20°C. The condensate comes out of condenser as saturated liquid. Find (a) the mass of steam supplied to the turbine per hour, (b) Capacity of the pump to circulate water, (c) the heat transfer area of the condenser if the overall heat transfer coefficient is 400 W/m²°C. Ans.[(a) 22.5kg/s, (b) 926.6 kg/s, (c) 7,135 m²|arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Physics - Thermodynamics: (21 of 22) Change Of State: Process Summary; Author: Michel van Biezen;https://www.youtube.com/watch?v=AzmXVvxXN70;License: Standard Youtube License