Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 5, Problem 5.11.6P
To determine
(a)
The W shape.
To determine
(b)
The W shape.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
PROBLEM 4:
The beam shown the figure below is a W16x31 of A992 steel and has continuous lat-
eral support. The two concentrated loads are service live loads. Neglect the weight of
the beam and determine whether the beam is adequate.
a. Use LRFD.
b. Use ASD.
60k
60k
W16 x 31
asap
+4
The beam shown in Figure is a W36 x182. It is laterally supported at A and B. The 300 kip load is a service live load. Using the unfactored service loads, a. Compute Cb. Do not include the beam weight in the loading. b. Compute Cb. Include the beam weight in the loading.
A simply supported beam is subjected to a uniform service dead load of 15kN/m(including the weight of the beam), a uniform service live load
of 30kN/m. the beam is 12 meters long and is laterally supported at the midspan, and A572 Gr.50 steel is used. Is W30x108 adequate? Assume
Cb=1
by
4
d
fore
k
h
h
Z
S
Ly
267 TH
mm
19.3
757
13.8
min
m
35.8
685.4
54.6
737.7
5670 x10^3
4900 x103
mm
60.8 x10 6 mm
2080 x10 3
8300 x10^9
mm
www
Chapter 5 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 5 - Prob. 5.2.1PCh. 5 - Prob. 5.2.2PCh. 5 - Verify the value of Zx for a W1850 that is...Ch. 5 - Prob. 5.2.4PCh. 5 - Prob. 5.4.1PCh. 5 - Prob. 5.4.2PCh. 5 - Determine the smallest value of yield stress Fy,...Ch. 5 - Prob. 5.5.1PCh. 5 - Prob. 5.5.2PCh. 5 - Prob. 5.5.3P
Ch. 5 - Prob. 5.5.4PCh. 5 - Prob. 5.5.5PCh. 5 - Prob. 5.5.6PCh. 5 - Prob. 5.5.7PCh. 5 - Prob. 5.5.8PCh. 5 - Prob. 5.5.9PCh. 5 - If the beam in Problem 5.5-9 i5 braced at A, B,...Ch. 5 - Prob. 5.5.11PCh. 5 - Prob. 5.5.12PCh. 5 - Prob. 5.5.13PCh. 5 - Prob. 5.5.14PCh. 5 - Prob. 5.5.15PCh. 5 - Prob. 5.5.16PCh. 5 - Prob. 5.6.1PCh. 5 - Prob. 5.6.2PCh. 5 - Prob. 5.6.3PCh. 5 - Prob. 5.6.4PCh. 5 - Compute the nominal shear strength of an M107.5 of...Ch. 5 - Compute the nominal shear strength of an M1211.8...Ch. 5 - Prob. 5.8.3PCh. 5 - Prob. 5.8.4PCh. 5 - Prob. 5.10.1PCh. 5 - Prob. 5.10.2PCh. 5 - Same as Problem 5.10-2, except that lateral...Ch. 5 - Prob. 5.10.4PCh. 5 - The given beam is laterally supported at the ends...Ch. 5 - Prob. 5.10.6PCh. 5 - Prob. 5.10.7PCh. 5 - Prob. 5.11.1PCh. 5 - Prob. 5.11.2PCh. 5 - Prob. 5.11.3PCh. 5 - Prob. 5.11.4PCh. 5 - Prob. 5.11.5PCh. 5 - Prob. 5.11.6PCh. 5 - Prob. 5.11.7PCh. 5 - Prob. 5.11.8PCh. 5 - Prob. 5.11.9PCh. 5 - Prob. 5.12.1PCh. 5 - Prob. 5.12.2PCh. 5 - Prob. 5.12.3PCh. 5 - Prob. 5.13.1PCh. 5 - Prob. 5.13.2PCh. 5 - Prob. 5.14.1PCh. 5 - Prob. 5.14.2PCh. 5 - Prob. 5.14.3PCh. 5 - Prob. 5.14.4PCh. 5 - Prob. 5.15.1PCh. 5 - Prob. 5.15.2PCh. 5 - Prob. 5.15.3PCh. 5 - Prob. 5.15.4PCh. 5 - Prob. 5.15.5PCh. 5 - Prob. 5.15.6PCh. 5 - Prob. 5.15.7PCh. 5 - Same as Problem 5.15-7, except that the sag rods...
Knowledge Booster
Similar questions
- A beam must be designed to the following specifications: Span length = 35 ft Beam spacing = 10 ft 2-in. deck with 3 in. of lightweight concrete fill (wc=115 pcf) for a total depth of t=5 in. Total weight of deck and slab = 51 psf Construction load = 20 psf Partition load = 20 psf Miscellaneous dead load = 10 psf Live load = 80 psf Fy=50 ksi, fc=4 ksi Assume continuous lateral support and use LRFD. a. Design a noncomposite beam. Compute the total deflection (there is no limit to be checked). b. Design a composite beam and specify the size and number of stud anchors required. Assume one stud at each beam location. Compute the maximum total deflection as follows: 1. Use the transformed section. 2. Use the lower-bound moment of inertia.arrow_forwardIf the beam in Problem 5.5-9 i5 braced at A, B, and C, compute for the unbr Cb aced length AC (same as Cb for unbraced length CB). Do not include the beam weight in the loading. a. Use the unfactored service loads. b. Use factored loads.arrow_forwardSelect an A992 W-shape for beam AB of the floor system shown in Figure. In addition to the weight of the beam, the dead load consists of a 5-inch-thick reinforced concrete slab (normal-weight concrete). The live load is 80 psf, and there is a 20-psf partition load. The total deflection must not exceed L/240. a. Use LRFD. b. Use ASDarrow_forward
- The beam shown in Figure is a W16 x 31 of A992 steel and has continuous lateral support. The two concentrated loads are service live loads. Neglect the weight of the beam and determine whether the beam is adequate. a. Use LRFD. b. Use ASD.arrow_forwardASSIGNMENT #5 BIAXIAL BENDING Problem: Check the beam shown for compliance with the NSCP Specification. Lateral support is provided only at the ends, and A992 steel is used, F, = 345 mPa. The 90 kN service loads are 30% dead load and 70% live load. a. Use LRFD b. Use ASD d tw by ty 1x(106) S(10³) mm mm mm mm³ mm mmª W410x100 415 10 260 16.9 398 1920 SECTION Tx mm 177 1m 90 kN 90 KN 1.5m W410x100 I Loaded Section Ly(106) Sy(10³) Ty mmª mm³ mm 49.5 381 62.4 1m Zx(10³) Zy(10³) mm³ mm³ 2130 581arrow_forwardRefer to the beam loading diagram shown If the beam is made from A992 and is continuously braced, determine the most economical member W-shape for strength only I am using AISC Steel Construction Manual 15th Edition. For the double fixed-end bend shown, the following data applies: • Service live load, P = 30 kips Required live load factor: 1.6 Beam length, L = 30 ft Self-weight has already been included. A В C 0.5L 0.5Larrow_forward
- SITUATION 2 Determine the safe service load W permitted for this beam-column that is not part of a frame system. Assume ASTM A992 (Fy = 350 MPa; Fu = 450 MPa) as material. Use LRFD specifications. Servise koada P= 30 kips dead load 80 kips live koad Assume hinged for both principal 10- 0 directions W- 20 dead load 8OG live load 10-o Fined for both principal directions Type your final answer/s in the text box provided below.arrow_forwardThe beam shown in Figure is laterally braced at A, B, C, and D. Is a W18 × 119 adequate forFy = 50 ksi?a. Use LRFDb. Use ASD.arrow_forwardPLEASE ANSWER ALL OF THIS QUESTION ASAP!!!arrow_forward
- 1. A steel column 10 m long is fabricated from a cover plate and C section arranged as shown. Determine the safe compressive load. Fy = 248 MPa, E= 200 GPa. Use AISC/NSCP Specs. 450 mm -cover plate 'I 12 mm y2 IP d2 10 m C 310 x 37 A = 4720 mm? d = 305 mm bf = 77 mm tf = 12.7 mm tw = 9.8 mm C 310 X 37 a) Both ends of column are fixed b) Both ends of column are hinged c) One end fixed, the other end hinged Use design values of k. tw d=305- Ix = 59.9x10° mm ly = 1.85x10° mm x = 17.1 mm x=17.1arrow_forwardColumnarrow_forwardHelp me pls i give upvotee33earrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning