A building has floor plan dimensions of
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
* It required to design a ducting system to condition the building shown in figure (1). The
uantity of outdoor is (20%) of supply air. Using information in table, find
1- The sensible and latent load for cooling coil.
2- The quantity and condition of supply air to each place.
3- By using equal pressure drop method, design the rectangular ducting system with
maximum height side (600mm).
4- Illustrate the all process on psychometric chart.
Outdoor
45 °C db & 30% RH
Out let type
Celling
conditioning
indoor conditioning 24 °C db & 50% RH
diffuser
Number of diffuser
2 for each
place
15 kpa
10 kpa
15 kpa
By pass factor
Apparatus dew point 9°C
Ap losses diffuser
Ap losses filter
Ap losses coil
0.15
R/w
1.5
бm
бm
бm
Room (1)
Room (2)
RSH=6KW
Room (3)
4m
RSH=8KW
RSH=8KW
RLH=2KW
RLH=1KW
RLH=2KW
2m
AHU
Mechanical
Room (4)
RSH=20KW
4m
Room
RLH=3KW
4m
14m
* It required to design a ducting system to condition the building shown in figure (1). The
uantity of outdoor is (20%) of supply air. Using information in table, find
1- The sensible and latent load for cooling coil.
2- The quantity and condition of supply air to each place.
3- By using equal pressure drop method, design the rectangular ducting system with
maximum height side (600mm).
4- Illustrate the all process on psychometric chart.
Outdoor
45 °C db & 30% RH
Out let type
Celling
conditioning
indoor conditioning 24 °C db & 50% RH
diffuser
Number of diffuser
2 for each
place
15 kpa
10 kpa
15 kpa
By pass factor
Apparatus dew point 9°C
Ap losses diffuser
Ap losses filter
Ap losses coil
0.15
R/w
1.5
6m
6m
6m
Room (1)
Room (2)
Room (3)
4m
RSH=8KW
RSH=6KW
RSH=8KW
RLH=2KW
RLH=1KW
RLH=2KW
2m
AHU
Mechanical
Room (4)
RSH=20KW
4m
Room
RLH=3KW
4m
14m
the compression ratio is given. answer what is the cut off ratio, thermal efficiency, and mean efffective pressure
Chapter 5 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Ch. 5 - Determine the thermal conductivity of 4 in. (100...Ch. 5 - Compute the unit conductance C for 512 in. (140...Ch. 5 - Compute the unit thermal resistance and the...Ch. 5 - What is the unit thermal resistance for an inside...Ch. 5 - Compute the thermal resistance per unit length for...Ch. 5 - Assuming that the blocks are not filled, compute...Ch. 5 - The partition of Problem 5-4 has still air on one...Ch. 5 - The pipe of Problem has water flowing inside with...Ch. 5 - Compute the overall thermal resistance of a wall...Ch. 5 - Compute the overall heat-transfer coefficient for...
Ch. 5 - Estimate what fraction of the heat transfer for a...Ch. 5 - Make a table similar to Table 5-4a showing...Ch. 5 - Estimate the unit thermal resistance for a...Ch. 5 - Refer to Problem 5-13, and estimate the unit...Ch. 5 - A ceiling space is formed by a large flat roof and...Ch. 5 - A wall is 20 ft (6.1 m) wide and 8 ft (2.4 m) high...Ch. 5 - Estimate the heat-transfer rate per square foot...Ch. 5 - A wall exactly like the one described in Table...Ch. 5 - Prob. 5.19PCh. 5 - Compute the overall heat-transfer coefficient for...Ch. 5 - Compute the overall heat transfer for a single...Ch. 5 - Determine the overall heattransfer coefficient for...Ch. 5 - A basement is 2020ft(66m) and 7 ft (2.13 m) below...Ch. 5 - Estimate the overall heat-transfer coefficient for...Ch. 5 - Rework Problem 5-23 assuming that the walls are...Ch. 5 - A heated building is built on a concrete slab with...Ch. 5 - A basement wall extends 6 ft (1.8 m) below grade...Ch. 5 - A 2440ft(7.312.2m) building has a full basement...Ch. 5 - The floor of the basement described in Problem...Ch. 5 - Assume that the ground temperature tg is 40 F (10...Ch. 5 - Use the temperatures given in Problem 5-30 and...Ch. 5 - A small office building is constructed with a...Ch. 5 - A 100 ft length of buried, uninsulated steel pipe...Ch. 5 - Estimate the heat loss from 100 m of buried...Ch. 5 - A large beverage cooler resembles a small building...Ch. 5 - Consider the wall section shown in Fig. 5-10. (a)...Ch. 5 - A building has floor plan dimensions of 3060ft....Ch. 5 - Compute the temperature of the metal roof deck of...Ch. 5 - Consider the wall section shown in Fig. -4a,...Ch. 5 - Consider the knee space shown in Fig. 5-11. The...Ch. 5 - Estimate the temperature in an unheated basement...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 1. If the thermal conductivity increase the heat transfer coefficient will 2.The rate of evaporation at a given operation in an evaporator is more when a.there is a vacuum b.the operating pressure is high c.when the feed flowrate is high d.the operating pressure is low 3.In fluid, if the currents are set in motion by the action of mechanical device, the flow is independent of density gradient, the phenomenon is called a.heatexchanger behavior b.natural convection C.forced convection d.thermal conductionarrow_forwardQUESTION 3 A manufacturer conducted an experiment for an evaporator capacity 500 kW cooling and designed for high COP of 2 when using lithium bromide plus water in an absorption refrigeration system. The evaporator operates 20 C, condenser 40 C & absorber 45 C supplying 1.4 kg/s of water plus lithium bromide solution to the generator. For a condenser size of 650 kW, determine: Show in your solution paper: Chart reading for Concentration and Enthalphy of solution being pumped Provide in the Answer Box: Enthalpy of solution being pumped in kJ/kgarrow_forwardA highly engineered Ecto-Containment System Protection Grid produces about 8 kW of waste heat in thesystem. A less highly-engineered tubular cross-flow heatsink is designed to dissipate that heat. In this case, the heat sink is a single long pipe carrying anti-freeze through the unit. The pipe has an OD of 80mm and and ID of 16mm. Assume that there is no resistance between the anti-freeze and the OD of the pipe (infinite conduction). Convection is forced, with an airflow of 12 m/s air across it Pr,air = 0.72, density(p) = 1.2 kg/m3, u = 16.83x10−6 Pa − S, k = 0.025 W/mk). The outside air is at 25℃ while the antifreeze is at 180℃. a) Find the Reynold’s Number of flow over the Pipe b) Find the convection coefficient across the pipe c) How long must the pipe be to dissipate all 8kW?arrow_forward
- 2. Calculate the heat loss for the structure described below. Use the indoor design setpoint of 70°F. ● . . . ● ● Hint: Utilize the Q=U*A*(ti-to) & Q = U'*P*(ti-to). Make sure to reference the following tables and examples to help assist you solve this problem; Table 5-5a, Table 5-8, Table 5-4a, Example 5-3, Eq. 5-23, and Fig 5-8. Given: i. Location: Des Moines, IA @ 99% winter OAT ii. Walls: Table 5.7, Construction 2 iii. Floor: Concrete slab with 2-ft, R-5.4, vertical edge insulation iv. Windows: Double-Insulating Glass; 1/4-in. air space; e = 0.6 on surface 2, 3x4-ft, double hung, reinforced vinyl frame; three on each side v. vi. Roof-Ceiling: Same as Example 5.3, height of 8-ft vii. House Plan: Single story, 36-ft x 64-ft Doors: Wood, 1-3/4-in. panel doors with metal storm doors, three each, 3x6.75-ft Qwindows = Qdoors= Qwalls = Qroof/ceiling= Qfloor = QTOTAL = Btu/(hroft²0F) Btu/h Heat Loss Btu/h Heat Loss Btu/h Heat Loss Btu/h Heat Loss Btu/h Heat Lossarrow_forwardQL.Compute the total heat gain load from all the sources into the lunchroom ,if the lunchroom is located at the top floor of an air conditioned commercial building. The lunchroom has one exposed wall facing SE. -Wall facing SE, (20 * 15); 12 brick, the overall heat transmission value(U) is 0.3 Btu/hr.ft². F. -Roof; 6 concrete with 2" insulation, Uroof 0.4 Btu/hr.ft².F - Windows facing SE ;No.(3), (3 *3),single regular plate,double-hung metal windows,weather-stripped; unlocked ,shaded with white inside roller shade,half drawn. -Occupants: (10) persons; sedentary work. -Lightening :2 Watt /ft² of the floor area (40' *20) -Outside conditions: T= 100 F (db) & T70(wb), DR =25 F, Vwind -10 mph. -Inside conditions: T-70 F (db) & Q=40%. -Location: 40 N.L, Time = 11 A.M.arrow_forwardA Copper ball at 40'Cis dropped in a mug containing water at 40°C. The heat will Select one: O a.not flow from Copper ball to water or from water to Copper ball O b. flow from Copper ball to water O c. Increase the temiperature of both O d. flow from water to Copper ballarrow_forward
- 6. A Thomas meter is located in an air duct of 2 sq ft cross-sectional area. The air weighs 0.083 lb per cu ft, and its specific heat is 0.24. Assume a controlled temperature differential of 5° and heater potential of 110 volts. Plot the velocity as abscissa and amperage as ordinate for veloc- ity 0 to 300 ft per min. Assume constant amperage of 3, and plot tem- perature difference against velocity. Discuss the curves from the stand- point of accuracy of the system. J: よ itet legeted oulindriool oir tubearrow_forwardI need right solution with clear calculations. A workplace is occupied by 100 people who are averaging 250 Watts/person. The space is measured as 30 meters x 20 meters x 15 meters (L x W x H). What is the internal heat gain of this space given off by a full staff? If you need to provide the workplace 10 air changes per hour, what type of infiltration inflow rate need to be (cubic meters/hour)?arrow_forwardAn ammonia compressor has a 5 percent clearance volume and a displacement rate of 80'L/s and pumps against a condensing temperature of 40 C. For the two different evaporating temperatures of -10 and 10 C, compute the refrigerant flow rate assuming that the clearance volumetric efficiency applies.arrow_forward
- The operators have noticed that the performance of the reactor is somewhat different to thedesign specifications and suspect that the thermal cycling may be responsible. The seniorprocess engineer would like you to analyse two periods:- The period when the reactor is initially heated up and held at the operating temperature.- The period after the reactor is taken offline for maintenance and then heated up again.You should consider the effect of the tube expansion on the operating variables and theoverall effect on pressure drop and conversion. Compare these responses to the estimatedperformance according to the design basis.You may include any equations or diagrams that you consider necessary to support yourdiscussion. A numerical solution is not required.Hints: A general consideration of the design method for fixed bed reactors may revealrelationships between operating and performance variables.arrow_forwardThe operators have noticed that the performance of the reactor is somewhat different to thedesign specifications and suspect that the thermal cycling may be responsible. The seniorprocess engineer would like you to analyse two periods:- The period when the reactor is initially heated up and held at the operating temperature.- The period after the reactor is taken offline for maintenance and then heated up again.You should consider the effect of the tube expansion on the operating variables and theoverall effect on pressure drop and conversion. Compare these responses to the estimatedperformance according to the design basis.You may include any equations or diagrams that you consider necessary to support yourdiscussion. A numerical solution is not required.arrow_forwardExample design a winter air conditioning power plant for a neighborhood of your choice (preheater/final heater andMust be humidification cells). Audible heat loss of the neighborhood is 50 kW, hidden heat gain is 20 kWhave been calculated. 1-) Show the process in the psychrometric diagram. 2-) Calculate the total amount of air circulating in the system 3-) Calculate the amount of water sprayed into the air in the humidifier 4-) Calculate the preheater capacity. 5-) Calculate final heater capacityarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license