Textbook Question
Chapter 8, Problem 8.8P
Research and describe current state-of-the-art electronic modules to measure temperature using an RTD sensor. List typical specifications that could be used in a design stage uncertainty analysis.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Discuss the importance of measuring devices for Electric Motor and Internal Combustion Engine in terms of accuracy.
1-
Change in temperature is a physical input variable of a sensor.
Select one:
True
False
Answer the following questions, to test your understanding of sampling frequency and bit depth.
1. You are part of new automobile design team, and are responsible for designing the sensor data
collection system. The specification of the data collection system is that is must be capable of
receiving data with a resolution down to 0.1% of full scale (1 part in 1000) for any given sensor.
For example, suppose the driver pushes the gas pedal, the motion of which is read by an
electronic sensor such that the range of motion is defined from 0 (not pressed) to 1 (fully
pressed). If you want 0.1 % accuracy, you need 1000 possible data values between 0 and 1.
How many bits do you need to represent data to 0.1% accuracy?
Insert a picture of your work.
Chapter 8 Solutions
Theory and Design for Mechanical Measurements
Ch. 8 - Prob. 8.1PCh. 8 - Fixed temperature points in the International...Ch. 8 - Answers to the following questions may be found in...Ch. 8 - Calculate the resistance of a platinum wire that...Ch. 8 - Plot the resistance of a platinum wire that is 5 m...Ch. 8 - An RTD forms one arm of a Wheatstone bridge, as...Ch. 8 - An RTD forms one arm (/?4) of a Wheatstone bridge,...Ch. 8 - Research and describe current state-of-the-art...Ch. 8 - Prob. 8.9PCh. 8 - 8.10 Estimate the required level of uncertainty in...
Ch. 8 - 8.11 A thermistor is placed in a 100 °C...Ch. 8 - Prob. 8.12PCh. 8 - Prob. 8.13PCh. 8 - The thermocouple circuit in Figure 8.45 represents...Ch. 8 - The thermocouple circuit in Figure 8.45 represents...Ch. 8 - The thermocouple circuit in Figure 8.45 is...Ch. 8 - 8.17 a. The thermocouple shown in Figure 8.46a...Ch. 8 - Prob. 8.18PCh. 8 - Prob. 8.19PCh. 8 - A temperature measurement requires an uncertainty...Ch. 8 - A temperature difference of 3.0 °C is measured...Ch. 8 - Complete the following table for a J-type...Ch. 8 - Complete the following table for a T-type...Ch. 8 - Prob. 8.24PCh. 8 - 8.25 You are employed as a heating, ventilating,...Ch. 8 - A J-type thermocouple for use at temperatures...Ch. 8 - A J-type thermocouple is calibrated against an RTD...Ch. 8 - A beaded thermocouple is placed in a duct in a...Ch. 8 - Consider a welded thermocouple bead that...Ch. 8 - Prob. 8.30PCh. 8 - Prob. 8.31PCh. 8 - Consider the typical construction of a sheathed...Ch. 8 - An iron-constantan thermocouple is placed in a...Ch. 8 - Figure 8.48 Schematic diagram for Problems 8.33,...Ch. 8 - Figure 8.48 Schematic diagram for Problems 8.33,...Ch. 8 - 8.36 In Example 8.5, an uncertainty value for Rf...Ch. 8 - The thermocouple circuit shown in Figure 8.49...Ch. 8 - Prob. 8.38PCh. 8 - 8.39 A thin-film heat flux sensor employs a K-type...Ch. 8 - A thin-film heat flux sensor has a sensitivity uV...Ch. 8 - 8.41 A T-type thermopile is used to measure...Ch. 8 - 8.42 A T-type thermocouple referenced to 0 °C is...Ch. 8 - A T-type thermocouple referenced to 0 °C develops...Ch. 8 - 8.44 A temperature measurement system consists of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- b) Figure 1 shows the calibration data of a sensor. Determine the static sensitivity at the input of X= 0, X= 5 and X= 10. For which input values is the system more sensitive? Calibration Data 300 250 y = 0.875x1.055 200 150 100 50 20 40 60 80 100 120 Input value, cm Figure 1 c) Suppose you found a dial thermometer in a stockroom. Discuss several methods by which you might estimate random and systematic error in the thermometer? How would you estimate its uncertainty? Output value, Varrow_forwardWhat is an example of experimental uncertainty?arrow_forwardGiven that your application requires high precision measurements, and you have varieties of a sensor type having the following different magnitude ratios M at your disposal. Pick the best sensor. A. M = 0.70 B. M = 1.50 C. M = 5.01 F. M = 10.00 G. 1.11 H. 0.65 D. M = 1.99 I. 4.21 E. M = 0.98 J. 0.67arrow_forward
- 3. Microfluidic channels will need to be fabricated on a key micro-scale sensor used by aerospace industries. Before running machining tests and analyzing machined quality, preliminary efforts are needed to evaluate selected materials and factors affecting machining process¹. Three material candidates have been selected, including 422SS (stainless steel), IN718 (nickel alloy), and Ti64 (titanium alloy) with their measured tensile properties and equation of true stress-true strain relationship used listed below. Tref25°C. Specifically, three factors will need to be evaluated, including different materials, temperature, and size effect. Please calculate true stress values for true strain ranging between 0-3 for each case listed below. Material A (MPa) & (S-¹) Tm (°C) 870 0.01 1520 422SS (Peyre et al., 2007) IN718 (Kobayashi et al., 2008) Ti64 (Umbrello, 2008) 980 1 1300 782.7 1E-5 1660 Material 422SS (CINDAS, 2011) IN718 (Davis, 1997) Ti64 (Fukuhara and Sanpei, 1993) 0 = X G (GPa) 1+ B…arrow_forwardYou’re testing a system that involves a fan, water pump, and compressor. The components are turned ON in sequence and sensor readings are taken, as per a written protocol that you’re following. The system is running as expected after the fan and water pump are turned ON. However, when you turn ON the compressor, it runs for about thirty seconds then stops, consistently. Swapping out the compressor for a different one seems to solve the problem. What could have been the issue with the bad compressor?arrow_forwardA temperature measurement system is composed of a sensor and a readout device. The readout device has a claimed accuracy of 0.6 °C with a resolution of 0.1 °C. The sensor has an off-the-shelf limit of error of 0.5 °C. Estimate a design-stage uncertainty in the temperature indicated by this combination. A displacement transducer has the following specifications: Linearity error:±0.25% reading Drift:±0.05%/°C reading Sensitivity error: ±0.25% reading Excitation: 10-25 V Output: dc 0-5Vdc Range: 0-5 cm The transducer output is to be indicated on a voltme- ter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Estimate an uncertainty in a nominal displacement of 2 cm at the design stage. Assume 95% confidence.arrow_forward
- You have installed a pressure sensor in Saudi Pak Towers, the sensors some time gives wrong value due to various reason. Identify techniques through which you can get stable value from this sensor Sample of data is given as 15,12,13,15,14,13,16,16,11,12,12. Also analyze error if true temperature recorded temperature is 12 degreearrow_forwardA temperature measurement system has the following specifications: -128 to 781°C Range Linearity error 0.29% FSO Hysteresis error 0.12% FSO Sensitivity error 0.04% FSO Zero drift 0.32% FSO FSO stands for "Full Scale Output". Estimate the overall instrument uncertainty for this system based on the available information. Use the maximum possible output range over the FSO in your computations.arrow_forwardQ7. A wind turbine consists primarily of a generator and gearbox. d) Describe some of the techniques that might be used in order to develop a predictive maintenance system for a wind turbine. Consider some of the sensing techniques that might be used and what parameters might be measured in order to detect component degradation.arrow_forward
- Compare the electromagnetic vibration sensor and piezoelectric vibration sensor types in terms of EMI resistance, off-axis sensitivity, mounting orientation, and mechanical durability, and hence make recommendations to improve the operating efficiency of the vibration monitoring unit. You are encouraged to use clearly labeled schematic diagrams to explain the principles of operation of the sensors in support of your arguments.arrow_forwardWhen ..... a seismic pickup system can be used to measure displacement, velocity, or acceleration .(accelerometer) mass, support stiffness, and O damping parameters are selected and an appropriate transducer is used mass, damping parameters are selected and an appropriate transducer is used mass and damping parameters are selected and an appropriate transducer is used mass, support stiffness, and damping parameters are usedarrow_forward2. Consider the voltmeter calibration data in Table 1. The sensitivity of the pressure sensor is 0.5 V/kPa (given by manufacturer) and the linear curve fit for the upscale calibration is given as y = 0.9829 x + 0.1095 . Plot the data using a suitable scale. a) Specify the percent maximum hysteresis based on full-scale range. b) Referring to increasing input calibration, determined the sensitivity and linearity errors. Increasing input (mV) Decreasing input (mV) Y Y 0.0 0.1 5.0 5.0 1.0 1.1 4.0 4.2 2.0 2.1 3.0 3.2 3.0 3.0 2.0 2.2 4.0 4.1 1.0 1.2 5.0 5.0 0.0 0.2 Table 1: Calibration resultsarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license