Textbook Question
Chapter 8, Problem 8.37P
The thermocouple circuit shown in Figure 8.49 measures the temperature Tj. The voltmeter limits of error are given as
Figure 8.49 Thermocouple circuit for Problem 8.37.
Limits of error: ±0.05% (95%) of reading +15 pV at 25°C
Resolution: 5 pV
Give a best estimate for the temperature T\, if the output voltage is 9 mV.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A thermocouple is used to
measure the temperature T1. The
thermocouple reference junction
labeled 2 is at a temperature of
20°C. The voltage output is
measured using a potentiometer
and found to be 4.686 mV. What
is T1 in degrees
RK: if the temperature values are
not in the table, you have to use
interpolation.
Select one:
O a. 98
O b. 118
O c. 105
O d. 108
Previous page
Next page
i. Derive the linear and quatratic approximation of the below resistance
temperature readings(temperature from 40 °c to 80 °c). (.
ii. find out the resistance of RTD at a temperature of 200°c using linear
approximation? (
Temperature 40
45
50
55
60[TO] 65
70
75
80
Resistance
ohm
115.239 120.521 167.096 254.966 384.13 554.587 766.34 1019.38 1313.724
A thermocouple has an output emf as shown in the following table when its hot (measuring) junction is at the temperatures shown. Determine the sensitivity of measurement for the thermocouple in mv/"C. Temperature (C) 3.5 13
4 12
Voltage imv)
Sensitivity, S
Chapter 8 Solutions
Theory and Design for Mechanical Measurements
Ch. 8 - Prob. 8.1PCh. 8 - Fixed temperature points in the International...Ch. 8 - Answers to the following questions may be found in...Ch. 8 - Calculate the resistance of a platinum wire that...Ch. 8 - Plot the resistance of a platinum wire that is 5 m...Ch. 8 - An RTD forms one arm of a Wheatstone bridge, as...Ch. 8 - An RTD forms one arm (/?4) of a Wheatstone bridge,...Ch. 8 - Research and describe current state-of-the-art...Ch. 8 - Prob. 8.9PCh. 8 - 8.10 Estimate the required level of uncertainty in...
Ch. 8 - 8.11 A thermistor is placed in a 100 °C...Ch. 8 - Prob. 8.12PCh. 8 - Prob. 8.13PCh. 8 - The thermocouple circuit in Figure 8.45 represents...Ch. 8 - The thermocouple circuit in Figure 8.45 represents...Ch. 8 - The thermocouple circuit in Figure 8.45 is...Ch. 8 - 8.17 a. The thermocouple shown in Figure 8.46a...Ch. 8 - Prob. 8.18PCh. 8 - Prob. 8.19PCh. 8 - A temperature measurement requires an uncertainty...Ch. 8 - A temperature difference of 3.0 °C is measured...Ch. 8 - Complete the following table for a J-type...Ch. 8 - Complete the following table for a T-type...Ch. 8 - Prob. 8.24PCh. 8 - 8.25 You are employed as a heating, ventilating,...Ch. 8 - A J-type thermocouple for use at temperatures...Ch. 8 - A J-type thermocouple is calibrated against an RTD...Ch. 8 - A beaded thermocouple is placed in a duct in a...Ch. 8 - Consider a welded thermocouple bead that...Ch. 8 - Prob. 8.30PCh. 8 - Prob. 8.31PCh. 8 - Consider the typical construction of a sheathed...Ch. 8 - An iron-constantan thermocouple is placed in a...Ch. 8 - Figure 8.48 Schematic diagram for Problems 8.33,...Ch. 8 - Figure 8.48 Schematic diagram for Problems 8.33,...Ch. 8 - 8.36 In Example 8.5, an uncertainty value for Rf...Ch. 8 - The thermocouple circuit shown in Figure 8.49...Ch. 8 - Prob. 8.38PCh. 8 - 8.39 A thin-film heat flux sensor employs a K-type...Ch. 8 - A thin-film heat flux sensor has a sensitivity uV...Ch. 8 - 8.41 A T-type thermopile is used to measure...Ch. 8 - 8.42 A T-type thermocouple referenced to 0 °C is...Ch. 8 - A T-type thermocouple referenced to 0 °C develops...Ch. 8 - 8.44 A temperature measurement system consists of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A temperature measurement system has the following specifications: -128 to 781°C Range Linearity error 0.29% FSO Hysteresis error 0.12% FSO Sensitivity error 0.04% FSO Zero drift 0.32% FSO FSO stands for "Full Scale Output". Estimate the overall instrument uncertainty for this system based on the available information. Use the maximum possible output range over the FSO in your computations.arrow_forwardA thermocouple produces an e.m.f. in mV according to the temperature difference between the sensor tip 0, and the reference junction 02 (also called gauge head where the reference junction is embedded inside the display unit for the thermocouple) such that e = a(0, – 0,) + B(e; – e; ) a = 3.5x10? mv/deg and B = 8.2x106 mV/deg. The gauge head is at 20°C. The output is 10 mV. Calculate the temperature of the sensor.arrow_forwardThe temperature of a fluid is measured by immersing a type K thermocouple in it. The reference junction of the thermocouple is maintained at 0 °C in an ice bath and an output e.m.f. of 9.435 mV is measured, provided sensitivity of K thermocouple is 41 ⴏV/ °C. What is the indicated fluid temperature in K ?arrow_forward
- The following resistance of a platinum resistance thermometer were measured at a range of temperature. Determine the measurement sensitivity of the instrument in milli Ohms/ oC. Resistance (mῼ) Tempreture (oC) 210k 110 217k 89 221k 68 228k 47arrow_forwardExplain the significance of the following information given in the specification of the followingtransducer,Thermocouple Sensitivity: nickel chromium/nickel aluminum thermocouple: 0.039 mV/ºC when thecold junction is at 0 ºC.arrow_forwardConsider a measuring system consisting of a transducer, amplifier and a recorder, with sensitivity for each equipment given below: Transducer sensitivity 0.2 mV/°C Amplifier gain 2.0 V/mV Recorder sensitivity 5.0 mm/V .Calculate the total sensitivity of the measuring system.arrow_forward
- O Estimate the MRR (in cc/sec) of an alloy containing 18% cobalt, 62% nickel and 20% chromium during ECM with current of 500 ampere. The density of the alloy is 8.28 g/cc. The following data is available. Metal Gram atomic weight Velency Cobalt 58.93 Nickel 58.71 2 Chromium 51.99 Assume Faraday's constant is 96500 coulombs/ mole.arrow_forwardA laboratory temperature standard is used to calibrate an automated temperature measuring system from sensor through conditioning equipment to its final indicated output value. The measuring system sensor is placed in the identical environment as the standard sensor. The indicated output values from the system are compared over a range of temperatures based on many readings at each of six setpoint temperatures. Estimate a value for the systematic standard uncertainty in the offset correction of the temperature measuring system. Setpoint (C) Indicated Mean ("C) Offset ("C) 0.000 20.000 40.000 60.000 80.000 100.000 0.046 20.067 40.072 60.133 80.057 100.116 0.046 0.067 0.072 0.133 0.057 0.116arrow_forwardA temperature measurement system is composed of a sensor and a readout device. The readout device has a claimed accuracy of 0.6 °C with a resolution of 0.1 °C. The sensor has an off-the-shelf limit of error of 0.5 °C. Estimate a design-stage uncertainty in the temperature indicated by this combination. A displacement transducer has the following specifications: Linearity error:±0.25% reading Drift:±0.05%/°C reading Sensitivity error: ±0.25% reading Excitation: 10-25 V Output: dc 0-5Vdc Range: 0-5 cm The transducer output is to be indicated on a voltme- ter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Estimate an uncertainty in a nominal displacement of 2 cm at the design stage. Assume 95% confidence.arrow_forward
- 9.11 A strain gauge, diaphragm pressure transducer (accuracy: <0.1% reading) is subjected to a pressure differential of 10 kPa. If the output is measured using a voltmeter having a resolution of 10 mV and accuracy of better than 0.1% of the reading, estimate the uncertainty in pressure at the design stage. How does this change at 100 and 1,000 kPa?arrow_forwardConsider a system consisting of a three elements, with sensitivity values as below. Element 1 sensitivity 2.5 mV/°C Element 2 sensitivity 11 V/mV Total sensitivity 18 mm/°C .Calculate the sensitivity of Element 3 . Sensitivity of element 3 = mm/V.arrow_forward4. A proposal for a “Smart" car seat operates by detecting the weight of the passenger and comparing against various thresholds. If the weight of the passenger is below 15 kg, the car would prevent deployment of an air bag in a collision. A standard "passenger" has a weight of >50 kg. The empty seat weighs 25 kG. The weight sensor is constructed with a strain gauge placed in one of the 4 “feet" of the car seat. In this position, it detects exactly 1/4 of the weight of the car seat plus the passenger. It consists of a structure that has a pre-assembly length of 1 cm, and a stiffness of 1,000,000 N/m. A metal film strain gauge with a nominal resistance of 10 kN and a gage factor of 2.0 is attached to this structure so that the weight of the car seat causes tensile strain in the strain gauge that is the same magnitude as the strain in the feet. a) If the unloaded length of the "foot" is 1 cm, what is the length when seat is mounted after the installation? If a 50 kG passenger sits in the…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license