Question
Chapter 6.3, Problem 7E
Interpretation Introduction
Interpretation:
In normal-phase chromatography process, the reason needs to be explained for the change of solvent from less polar to more polar.
Concept Introduction :
Chromatography is a versatile method of separation extensively used to get pure compounds from mixtures.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Explain how the separation of various components of a mixture isachieved in column chromatography.
What is the stationary phase in thin layer chromatography and its polarity?
Choices:
Cellulose - non-polar
Cellulose - polar
Silica - non-polar
Silica - polar
Given below is a diagram of separation of two components of a mixture in a reverse phase chromatographic column. From the diagram, which component is the most non-polar?
Chapter 6 Solutions
EBK EXPERIMENTAL ORGANIC CHEMISTRY: A M
Ch. 6.2 - Prob. 1ECh. 6.2 - Prob. 2ECh. 6.2 - Prob. 3ECh. 6.2 - Prob. 4ECh. 6.2 - Prob. 5ECh. 6.2 - Prob. 6ECh. 6.2 - Prob. 7ECh. 6.2 - Prob. 8ECh. 6.2 - Prob. 9ECh. 6.3 - Prob. 1E
Ch. 6.3 - Prob. 2ECh. 6.3 - Prob. 3ECh. 6.3 - Prob. 4ECh. 6.3 - Prob. 5ECh. 6.3 - Prob. 6ECh. 6.3 - Prob. 7ECh. 6.3 - Prob. 8ECh. 6.3 - Prob. 9ECh. 6.3 - Prob. 10ECh. 6.3 - Prob. 11ECh. 6.3 - Prob. 12ECh. 6.3 - Prob. 13ECh. 6.3 - Prob. 14ECh. 6.3 - Prob. 15ECh. 6.3 - Prob. 16ECh. 6.3 - Prob. 17ECh. 6.3 - Prob. 18ECh. 6.3 - Prob. 19ECh. 6.3 - Prob. 20ECh. 6.4 - Prob. 1ECh. 6.4 - Prob. 2ECh. 6.4 - Prob. 3ECh. 6.4 - Prob. 4ECh. 6.4 - Prob. 5E
Knowledge Booster
Similar questions
- what is chromatography? Explain different types of chromatography and explain how to seperate compounds. indicate stationary phase mobile phase.arrow_forwardGas chromatography cannot analyze mixtures due to the sensitivity of the instrument. True Falsearrow_forwardIn molecular exclusion (size exclusion) chromatography, the molecules have the longest retention times. a) the larger molecules b) the smaller moleculesarrow_forward
- True or False: Liquid-solid phase column chromatography is used to separate large up to multigram amounts of mixtures, based on their differences (however small) in polarity.arrow_forwardIs thin-layer chromatography a type of normal-phase chromatography or a type of reverse-phase chromatography? Define these two classifications.arrow_forwardDifferentiate normal phase chromatography from reverse phase chromatography. From which of the two governs the video demonstration in TLC and paper chromatography? How do you say so?arrow_forward
- In color chromatography of plant pigments, what complications would a dried-out column (solvent level is below the top of the silica) introduce to the elution and isolation of pigments?arrow_forwardNonearrow_forwardWhich statements are true for molecular exclusion chromatography?I Molecular exclusion chromatography separates on the basis of size.II Small molecules that freely pass through the stationary phase, Kav = 0.III Small molecules can fit in the pores of the stationary phase and effectively pass through a larger volume, and elute last.IV The pores in the stationary phase are too small for large molecules to pass through, so large molecules elute last.V Molecular exclusion chromatography with a hydrophilic stationary phase and an aqueous solvent is called gel permeation chromatography. A. II and V B. I, II, and IV C. III, IV, and V D. No correct combinations given above E. I, III, and IV F. I, II, III, and Varrow_forward
- One method for the quantitative determination of the concentration of constituents in a sample analyzed by gas chromatography is area normalization. Here, complete elution of all the sample constituents is necessary. The area of each peak is then measured and corrected for differences in detector response to the different eluates. This correction involves dividing the area by an empirically determined correction factor. The concentration of the analyte is found from the ratio of its corrected area to the total corrected area of all peaks. For a chromatogram containing three peaks, the relative areas were found to be 16.4, 45.2 and 30.2, in order of increasing retention time. Calculate the percentage of each compound if the relative detector responses were 0.60, 0.78 and 0.88, respectively.arrow_forwardYou have obtained a gas chromatogram of a two component mixture of compounds A and B. The height of peak A is 3.84 cm. and the width at half height is 1 cm. The height of peak B is 3.49 cm. and the width at half height is 1.36 cm. The percentage of a component in the mixture is proportional to peak area. Estimate peak areas by multiplying height by width at half height. What was the percentage of compound B in the mixture? (Enter your answer as a number without any percent symbol or the word percent.)arrow_forwardExplain the following (1) Column Chromatography(CC) (2) Paper Chromatography (3) Thin Layer Chromatography(TLC) (4) Gas Chromatography (GC)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning