Theory and Design for Mechanical Measurements
6th Edition
ISBN: 9781118881279
Author: Richard S. Figliola, Donald E. Beasley
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 5, Problem 5.39P
The power usage of a strip heater is to be determined by measuring heater resistance and heater voltage drop simultaneously. The resistance is to be measured using an ohmmeter having a resolution of 1 £2 and uncertainty of 1% of reading, and voltage is to be measured using a voltmeter having a resolution of 1 V and uncertainty of 1% of reading. It is expected that the heater will have a resistance of 100 £2 and use 100 W of power. Determine the
uncertainty in power determination to be expected with this equipment at the design stage.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A temperature measurement system has the following specifications:
-128 to 781°C
Range
Linearity error
0.29% FSO
Hysteresis error
0.12% FSO
Sensitivity error
0.04% FSO
Zero drift
0.32% FSO
FSO stands for "Full Scale Output". Estimate the overall instrument
uncertainty for this system based on the available information. Use the
maximum possible output range over the FSO in your computations.
0.6. The resistance of a certain size of copper wire is given as.
R = Ro[1 + a(T-20)]
%3D
where Ro-60+0.3 percent is the resistance at 20°C, a=0.004°C-1+1 percent is the temperature
coefficient of resistance, and the temperature of the wire is T=30°C + 1 percent. Calculate the
resistance of wire and its uncertainty.
A J-type thermocouple is used to measure the unknown steady-state temperature of a
liquid. The sensor outputs a voltage of 2.532 mV. Using Equation 2 and Table 1.2,
determine the unknown temperature. Show all calculations and assume the
thermocouple is referenced to 0 °C.
T = a₁ + a₂V + ·
...+ a₂V²
a
a₁
0.000 000
1.978 425 x 10-²
-2.001 204 x 10¹7
1.036 969 x 10-¹1
-2.549 687 x 10-16
3.585 153 x 10-21
-5.344 285 x 10.26
5.099 890 x 10:³1
Table 1.2 -J-type thermocouple polynomial coefficients over the range of 0°C to 760°C ± 0.04°C
8₂
a3
a4
(2)
as
as
a7
Chapter 5 Solutions
Theory and Design for Mechanical Measurements
Ch. 5 - Prob. 5.1PCh. 5 - Explain what is meant by the terms “true value,"...Ch. 5 - SJ An official Olympics timekeeper once stated,...Ch. 5 - A tachometer has an analog display dial graduated...Ch. 5 - An automobile speedometer is graduated in 5-mph...Ch. 5 - An engineer reads the height of a mercury...Ch. 5 - Prob. 5.8PCh. 5 - Two resistors arc to be combined to form an...Ch. 5 - An equipment catalog boasts that a pressure...Ch. 5 - The shear modulus, G, of an alloy can be...
Ch. 5 - Heat transfer from a rod of diameter D immersed in...Ch. 5 - Estimate the design-stage uncertainty in...Ch. 5 - Explain the critical dift'erence(s) between a...Ch. 5 - A displacement transducer has the following...Ch. 5 - Prob. 5.18PCh. 5 - For a thin-walled pressure vessel of diameter D...Ch. 5 - Suppose a measured normal stress contains three...Ch. 5 - Prob. 5.31PCh. 5 - The area of a flat, rectangular parcel of land is...Ch. 5 - Estimate the random standard uncertainty in the...Ch. 5 - Estimate the uncertainty at 95% confidence in the...Ch. 5 - One use for a GPS rangefinder is on the golf...Ch. 5 - A pressure measuring system outputs a voltage that...Ch. 5 - The density of a metal composite is to be...Ch. 5 - A temperature measurement system is calibrated...Ch. 5 - The power usage of a strip heater is to be...Ch. 5 - The power usage of a DC strip heater can be...Ch. 5 - A thermocouple is a temperature sensor made of two...Ch. 5 - Time variations in a signal require that the...Ch. 5 - A hand-held infrared thermometer from a well-...Ch. 5 - The pressure in a large vessel is to be maintained...Ch. 5 - The cooling of a thermometer (c.g., Exs. 3.3 and...Ch. 5 - A J-type thermocouple monitors the temperature of...Ch. 5 - The density of air must be known to within 0.5%....Ch. 5 - In pneumatic conveying, solid particles such as...Ch. 5 - A step test is run to determine the time constant...Ch. 5 - The acceleration of a cart down a plane inclined...Ch. 5 - The heat flux in a reaction is estimated by Q =...Ch. 5 - A comparative test uses the relationship R =...Ch. 5 - A sensitive material is to be contained within a...Ch. 5 - A geometric stress concentration factor, K,, is...Ch. 5 - In Problem 5.9, we assumed that the errors in die...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A thermocouple is used to measure the temperature T1. The thermocouple reference junction labeled 2 is at a temperature of 20°C. The voltage output is measured using a potentiometer and found to be 4.686 mV. What is T1 in degrees RK: if the temperature values are not in the table, you have to use interpolation. Select one: O a. 98 O b. 118 O c. 105 O d. 108 Previous page Next pagearrow_forwarda) The mass of a test specimen of metal alloy is measured to be m = 674.4 g. The procedure has a standard uncertainty of 1.0 g. The volume of the specimen is measured to be V = 261.1 mL with an estimated standard uncertainty of 0.1 mL. Estimate the density of the specimen and its uncertainty. b) Determine the relative uncertainty in the calculated volume of a cylinder if its height h can be measured with a standard uncertainty to within 2% and its radius R can be measured with a standard uncertainty within 1%.arrow_forwardA resistor is measured with a device which has a known precision of ±0.075 k2 when a large number of measurements is taken. How many measurements are necessary to ensure that the resistance is within ±0.05 k2 with a 0.1l percent level of significance? Use the t -distribution.arrow_forward
- A textile fiber manufacturer is investigating a newdrapery yarn, which the company claims has a mean thread elongation of 12 kilograms with a standard deviation of 0.5 kilograms. The companywishes to test the hypothesis Ho:u = 12 against H1 :µ < 12, using a random sample of 4 specimens. Round your answers to 4 decimal places. (a) What is the type l error probability if the critical region is defined asa < I1.5 kilograms? The type l error probability is (b) Find ßfor the case where the true mean elongation is 11.28 kilograms. ß = 1 (C) Find ßfor the case where the true mean is 11.5 kilograms. Statistical Tables and Chartsarrow_forwardWhat is an example of experimental uncertainty?arrow_forwardCalculate the absolute uncertainty, fractional uncertainty, and percentile uncertaintyarrow_forward
- O Estimate the MRR (in cc/sec) of an alloy containing 18% cobalt, 62% nickel and 20% chromium during ECM with current of 500 ampere. The density of the alloy is 8.28 g/cc. The following data is available. Metal Gram atomic weight Velency Cobalt 58.93 Nickel 58.71 2 Chromium 51.99 Assume Faraday's constant is 96500 coulombs/ mole.arrow_forwardQ.1 a. Repeatability and reproducibility are ways of measuring precision, particularly in the field of engineering. i. What is an engineer's expectation when performing repeatability or reproducibility? ii. State a difference between repeatability and reproducibility in an experiment? b. Figure Q.1 shows the measurement data of two types of thermal transducers namely thermocouple. Турe E Туре К 6.8 4.2 20 40 60 80 100 Temperature Difference (°C) Voltage Output (mV)arrow_forwardA temperature measurement system is composed of a sensor and a readout device. The readout device has a claimed accuracy of 0.6 °C with a resolution of 0.1 °C. The sensor has an off-the-shelf limit of error of 0.5 °C. Estimate a design-stage uncertainty in the temperature indicated by this combination. A displacement transducer has the following specifications: Linearity error:±0.25% reading Drift:±0.05%/°C reading Sensitivity error: ±0.25% reading Excitation: 10-25 V Output: dc 0-5Vdc Range: 0-5 cm The transducer output is to be indicated on a voltme- ter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Estimate an uncertainty in a nominal displacement of 2 cm at the design stage. Assume 95% confidence.arrow_forward
- 9.11 A strain gauge, diaphragm pressure transducer (accuracy: <0.1% reading) is subjected to a pressure differential of 10 kPa. If the output is measured using a voltmeter having a resolution of 10 mV and accuracy of better than 0.1% of the reading, estimate the uncertainty in pressure at the design stage. How does this change at 100 and 1,000 kPa?arrow_forwardA handbook value for the thermal expansion coefficient of a particular pure metal is a = 16.52 X 10-6 °C-1 and states that the possible error in this value should not exceed 0.4 × 10-6 °C-¹. Assuming that the population for a follows a rectangular distribution, estimate the standard uncertainty to be assigned.arrow_forwardThe shear modulus, G, of a material can be determined by applying a torque, T, on a cylindrical material specimen and measuring the angular twist, 0. The modulus can then be calculated from: G the specimen radius and length, respectively, The relative uncertainty in each measured variable (L. T, t. 0. R) is + 3.7% 3LT where R and L are %3D 2 Ree What is the total relative uncertainty in G?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Extent of Reaction; Author: LearnChemE;https://www.youtube.com/watch?v=__stMf3OLP4;License: Standard Youtube License