Question
Chapter 3.3, Problem 18E
Interpretation Introduction
Interpretation:Different values of
Concept introduction:Retention factor or
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Why is CCL4 preferred over acetone as a solvent in running IR spectra of solids?
Which parameter between "solvent polarity function" and dielectric constant show better correlation with the peak positions? (cyclohexane, dioxane, acetonitrile, ethanol, ethylene glycol)
1- While cleaning out a laboratory shelf, you have
made a mistake in labeling two bottles of ethanol and
acetic acid. To identify the molecular structure of the
contents of the bottle, samples were submitted for
analysis using infrared spectroscopy, based on the IR
results, draw the molecular structure of the molecule
that would correspond to the spectrum for that
compound. Justify your answer
0.8
0.6-
0.4-
0.2
3000
2000
Wavenumber (cm-1)
1000
80
70
60
40
30-
20
10
2000
Wavenumbers (cm-1)
II
Transmitance
Chapter 3 Solutions
EBK EXPERIMENTAL ORGANIC CHEMISTRY: A M
Ch. 3.2 - Prob. 1ECh. 3.2 - Prob. 2ECh. 3.2 - Prob. 3ECh. 3.2 - Prob. 4ECh. 3.2 - Prob. 5ECh. 3.2 - Prob. 6ECh. 3.2 - Prob. 7ECh. 3.2 - Prob. 8ECh. 3.2 - Prob. 9ECh. 3.2 - Prob. 10E
Ch. 3.2 - Prob. 11ECh. 3.2 - Prob. 12ECh. 3.2 - Prob. 13ECh. 3.2 - Prob. 14ECh. 3.2 - Prob. 15ECh. 3.2 - Prob. 16ECh. 3.2 - Prob. 17ECh. 3.2 - Prob. 18ECh. 3.2 - Prob. 19ECh. 3.2 - Prob. 20ECh. 3.2 - Prob. 21ECh. 3.2 - Prob. 22ECh. 3.2 - Prob. 23ECh. 3.2 - Prob. 24ECh. 3.2 - Prob. 25ECh. 3.2 - Prob. 26ECh. 3.2 - Prob. 27ECh. 3.2 - Prob. 28ECh. 3.2 - Prob. 29ECh. 3.2 - Prob. 30ECh. 3.2 - Prob. 31ECh. 3.2 - Prob. 32ECh. 3.2 - Prob. 34ECh. 3.3 - Prob. 1ECh. 3.3 - Prob. 2ECh. 3.3 - Prob. 3ECh. 3.3 - Prob. 4ECh. 3.3 - Prob. 5ECh. 3.3 - Prob. 6ECh. 3.3 - Prob. 7ECh. 3.3 - Prob. 8ECh. 3.3 - Prob. 10ECh. 3.3 - Prob. 11ECh. 3.3 - Prob. 12ECh. 3.3 - Prob. 13ECh. 3.3 - Prob. 14ECh. 3.3 - Prob. 15ECh. 3.3 - Prob. 16ECh. 3.3 - Prob. 17ECh. 3.3 - Prob. 18ECh. 3.3 - Prob. 19ECh. 3.3 - Prob. 21ECh. 3.3 - Prob. 22ECh. 3.3 - Prob. 23ECh. 3.3 - Prob. 24ECh. 3.3 - Prob. 25ECh. 3.3 - Prob. 26E
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- The IR spectrum of 2-methyl-1-butanol (H;CCH,CH(CH;) CH,OH) and tert-butyl methyl ether [(CH;);COCH3] are shown below. Assign cach spectrum to the correct com- pound and identify the frequencies and the functional groups used to support your assignment. λ (μm) 6 7 8 9 10 11 12 1314 15 2.5 100 3 5 90 80 70 60 50 40 30 20 10 4000 3600 3200 2800 2400 2000 1800 1600 1400 1200 1000 800 600 400 Frequency (cm-1) A (µm) 7 8 9 10 11 12 13 14 15 2.5 100 3 5 20 4 6 90 80 70 60 50 40 30 20 10 4000 3600 3200 2800 2400 2000 1800 1600 1400 1200 1000 800 600 400 Frequency (cm¬!) (%) Transmission (%) Transmission 20arrow_forwardWhat structural features of Hydroxypropyl Acrylate (HPA) allow it to be detected by HPLC?arrow_forwardThe Beer-Lambert law you'll be using to determine the concentration of an unknown is A = ebc where A is the absorbance measured on the spectrometer, e (epsilon) is the molar absorptivity in M cm1, b is the path length of the cell (the diameter of the cuvette which is filled with solution), and c is the concentration of the solution in M. If you have a sample which has an absorbance of 1.17, a molar absorptivity of 1 Mcm1, and a cuvette that is 1.15 cm wide, what is the concentration of the sample in M? Give your answer to 3 decimal places (e.g.: 0.123)arrow_forward
- Why can UV or higher energy radiation not be used for non-destructive spectroscopy of polymer structure ? Why is resolution limited by wavelength?arrow_forwardWhy are solid forms of the sample are not suitable for Uv-visible spectroscopy and Fluorescence spectroscopy? Please shortly answer at your own words. Answer should be specific (3-4 lines).arrow_forwardMixtures can be quantified using UV-Vis spectroscopy. True Falsearrow_forward
- 1) How does IR radiation affect absorbing molecules? Name an example molecule that does not absorb IR and briefly explain why. 2) Suppose you are able to figure out, correctly, all of the functional groups for an unknown organic molecule using FTIR. Explain why this might not be sufficient to pin down the exact structure of the molecule. What additional information could be useful? 3) Explain the basic operating principle of an ATR based sampling system? Give the advantages of an ATR-based sampling system compared to one based on direct transmittance of IR radiation in terms of sample thickness and preparation techniques?arrow_forwardInstrumentation of IR spectroscopy? Please answer at your own words.arrow_forwardWhen compounds are prepared for IR analysis, they usually have to be dehydrated completely and then dissolved in a solvent other than water. Can you think of a reason why you might not want to have any H2O mixed in with your unknown compound when collecting its IR absorbance? Explain your rationale with respect to any observations about the spectra.arrow_forward
- 1. What is the physical basis ("physical basis" refers to the specific molecular, nuclei, electron, magnetic etc. interactions that are the actual source of the effect) for why the chemical shift difference, ie the frequency difference delta V, between peaks is on the order of magnitude of 10^-6, that of the absolute value of the frequencies involved?arrow_forwardFourier Transform Infrared (FTIR) is a common technique used to determine chemical functional groups of unknown molecule. For liquid samples, a drop of sample is placed between a pair of ionic solid pressed disks made from NaCl or KBr. Briefly explain why are sample holders for IR absorbance experiments often made from ionic solid pressed disks instead of glass vialsarrow_forwardTrue or False. 1. The absorbance of a sample is equal to the negative logarithm of the transmittance. 2. Winkler method of dissolve oxygen determination is an example of iodometry. 3. A diazo compound is produced when nitrite is reacted with sulfanilamide in acidic solution. 4. Atomic Absorption Spectroscopy can be used to analyze the functional groups of organic substances. 5. A diode array spectrometer use an absorption or interference filters for wavelength selection and a photoelectric device for measuring radiant power. 6. The oxidation state for the manganese in the brown solid which precipitate in Winkler method is +3 7. In Winkler method, the iodine produced is oxidized during sodium thiosulfate titration to iodide ion. 8. When the pH of the solution is adjusted to pH greater than 12, the EDTA reacts with magnesium ions only, because calcium precipitates as calcium hydroxide.arrow_forward