Chapter 12, Problem 54P
A balanced three-phase Y-source with VP = 880 V rms drives a Y-connected three-phase load with phase impedance ZA = 80 Ω, ZB = 60 + j90 Ω, and ZC = j80 Ω. Calculate the line currents and total complex power delivered to the load. Assume that the neutrals are connected.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Draw Wye- Delta three phase transformers connection ( no-load and full-load) in Lt-spice
Two delta connected loads are connected in parallel and powered by a balanced Y-connectedsource. The smaller of two loads draws 10 kVA at a lagging power factor of 0.75 and the largerdraws 25 kVA at a leading power factor of 0.8. The line voltage is 400 V. Calculate a) The powerfactor at which the source is operating. b) The total power drawn by the two loads. c) The phasecurrent of each load.
5. The figure below shows two star connected loads with three phase power. The
voltage source is 120Z0°. The loads are Z₁ = 10 + j4 № and Z₂ = 2 +j3 №. The
cables are negligible.
Calculate:
a)
the line and phase current.
b) the real power from the source.
c) the reactive power of the circuit.
Is
V
N
Z₁
Z₁ Z₁
Z₂
Z₂
N
N
Z₂
Chapter 12 Solutions
Fundamentals of Electric Circuits
Ch. 12.2 - Given that Vbn=22030V, find Van and Vcn, assuming...Ch. 12.3 - A Y-connected balanced three-phase generator with...Ch. 12.4 - One line voltage of a balanced Y-connected source...Ch. 12.5 - A positive-sequence, balanced -connected source...Ch. 12.6 - In a balanced -Y circuit, Vab=44015 and ZY = (12 +...Ch. 12.7 - For the Y-Y circuit in Practice Prob. 12.2,...Ch. 12.7 - Calculate the line current required for a 30-kW...Ch. 12.7 - Assume that the two balanced loads in Fig....Ch. 12.8 - The unbalanced -load of Fig. 12.24 is supplied by...Ch. 12.8 - Find the line currents in the unbalanced...
Ch. 12.9 - Prob. 11PPCh. 12.9 - For the unbalanced circuit in Fig. 12.32, use...Ch. 12.10 - Repeat Example 12.13 for the network in Fig. 12.24...Ch. 12.10 - Let the line voltage VL = 208 V and the wattmeter...Ch. 12.10 - If the load in Fig. 12.35 is delta-connected with...Ch. 12 - What is the phase sequence of a three-phase motor...Ch. 12 - If in an acb phase sequence, , then Vcn is:Ch. 12 - Which of these is not a required condition for a...Ch. 12 - Prob. 4RQCh. 12 - Prob. 5RQCh. 12 - In a Y-Y system, a line voltage of 220 V produces...Ch. 12 - In a - system, a phase voltage of 100 V produces a...Ch. 12 - When a Y-connected load is supplied by voltages in...Ch. 12 - Prob. 9RQCh. 12 - Prob. 10RQCh. 12 - If Vab = 400 V in a balanced Y-connected...Ch. 12 - What is the phase sequence of a balanced...Ch. 12 - Given a balanced Y-connected three-phase generator...Ch. 12 - A three-phase system with abc sequence and VL =...Ch. 12 - For a Y-connected load, the time-domain...Ch. 12 - Using Fig. 12.41, design a problem to help other...Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - In a balanced three-phase Y-Y system, the source...Ch. 12 - A balanced Y-Y four-wire system has phase voltages...Ch. 12 - For the circuit in Fig. 12.43, determine the...Ch. 12 - In the Y- system shown in Fig. 12.44, the source...Ch. 12 - Using Fig. 12.45, design a problem to help other...Ch. 12 - In the balanced three-phase Y- system in Fig....Ch. 12 - Obtain the line currents in the three-phase...Ch. 12 - The circuit in Fig. 12.48 is excited by a balanced...Ch. 12 - A balanced delta-connected load has a phase...Ch. 12 - A positive sequence wye-connected source where ,...Ch. 12 - If Van = 22060 V in the network of Fig. 12.49,...Ch. 12 - For the - circuit of Fig. 12.50, calculate the...Ch. 12 - Prob. 20PCh. 12 - Three 440-V generators form a delta-connected...Ch. 12 - Find the line currents IaA, IbB, and IcC in the...Ch. 12 - A balanced delta connected source is connected to...Ch. 12 - A balanced delta-connected source has phase...Ch. 12 - In the circuit of Fig. 12.54, if , , , find the...Ch. 12 - Using Fig. 12.55, design a problem to help other...Ch. 12 - A -connected source supplies power to a...Ch. 12 - The line-to-line voltages in a Y-load have a...Ch. 12 - A balanced three-phase Y- system has V rms and Z =...Ch. 12 - In Fig. 12.56, the rms value of the line voltage...Ch. 12 - A balanced delta-connected load is supplied by a...Ch. 12 - Design a problem to help other students better...Ch. 12 - A three-phase source delivers 4.8 kVA to a...Ch. 12 - A balanced wye-connected load with a phase...Ch. 12 - Three equal impedances, 60 + j30 each, are...Ch. 12 - A 4200-V, three-phase transmission line has an...Ch. 12 - The total power measured in a three-phase system...Ch. 12 - Given the circuit in Fig. 12.57 below, find the...Ch. 12 - Find the real power absorbed by the load in Fig....Ch. 12 - For the three-phase circuit in Fig. 12.59, find...Ch. 12 - A balanced delta-connected load draws 5 kW at a...Ch. 12 - A balanced three-phase generator delivers 7.2 kW...Ch. 12 - Refer to Fig. 12.48. Obtain the complex power...Ch. 12 - A three-phase line has an impedance of 1 + j3 per...Ch. 12 - A balanced wye-connected load is connected to the...Ch. 12 - A three-phase load consists of three 100-...Ch. 12 - The following three parallel-connected three-phase...Ch. 12 - A balanced, positive-sequence wye-connected source...Ch. 12 - Each phase load consists of a 20- resistor and a...Ch. 12 - A balanced three-phase source with VL = 240 V rms...Ch. 12 - Consider the wye-delta system shown in Fig. 12.60....Ch. 12 - A four-wire wye-wye circuit has...Ch. 12 - Using Fig. 12.61, design a problem that will help...Ch. 12 - A balanced three-phase Y-source with VP = 880 V...Ch. 12 - A three-phase supply, with the line-to-line...Ch. 12 - Using Fig. 12.63, design a problem to help other...Ch. 12 - Determine the line currents for the three-phase...Ch. 12 - Solve Prob. 12.10 using PSpice or MultiSim. For...Ch. 12 - The source in Fig. 12.65 is balanced and exhibits...Ch. 12 - Use PSpice or MultiSim to determine Io in the...Ch. 12 - Given the circuit in Fig. 12.67, use PSpice or...Ch. 12 - Using Fig. 12.68, design a problem to help other...Ch. 12 - Use PSpice or MultiSim to find currents IaA and...Ch. 12 - For the circuit in Fig. 12.58, use PSpice or...Ch. 12 - A balanced three-phase circuit is shown in Fig....Ch. 12 - A three-phase, four-wire system operating with a...Ch. 12 - As shown in Fig. 12.72, a three-phase four-wire...Ch. 12 - Meter readings for a three-phase wye-connected...Ch. 12 - A certain store contains three balanced...Ch. 12 - The two-wattmeter method gives P1=1200W and...Ch. 12 - In Fig. 12.73, two wattmeters are properly...Ch. 12 - If wattmeters W1 and W2 are properly connected...Ch. 12 - For the circuit displayed in Fig. 12.74, find the...Ch. 12 - Predict the wattmeter readings for the circuit in...Ch. 12 - Prob. 75PCh. 12 - Show that the I2R losses will be higher for a...Ch. 12 - A three-phase generator supplied 10 kVA at a power...Ch. 12 - Prob. 78CPCh. 12 - A balanced three-phase generator has an abc phase...Ch. 12 - A balanced three-phase source furnishes power to...Ch. 12 - A professional center is supplied by a balanced...Ch. 12 - A balanced three-phase system has a distribution...Ch. 12 - A commercially available three-phase inductive...Ch. 12 - Figure 12.76 displays a three-phase...Ch. 12 - Design a three-phase heater with suitable...Ch. 12 - For the single-phase three-wire system in Fig....Ch. 12 - Consider the single-phase three-wire system shown...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Three single-phase transformers, each rated 10MVA,66.4/12.5kV,60Hz, with an equivalent series reactance of 0.1 per unit divided equally between primary and secondary, are connected in a three-phase bank. The high-voltage windings are V-connected and their terminals are directly connected to a 115-kV three-phase bus. The secondary terminals are all shorted together. Find the currents entering the high-voltage terminals and leaving the low-voltage terminals if the low-voltage windings are (a) Y-connected and (b) - connected.arrow_forwardTwo balanced Y-connected loads, one drawing 10 kW at 0.8 power factor lagging and the other IS kW at 0.9 power factor leading, are connected in parallel and supplied by a balanced three-phase Y-connected, 480-V source. (a) Determine the source current. (b) If the load neutrals are connected to the source neutral by a zero-ohm neutral wire through an ammeter, what will the ammeter read?arrow_forwardVA-120 V4120 Z₁ volt In lc c ZA Three-phase source Feeder lines Balanced load In the above circuit diagram, we have source impedance Zg = 0.05+j0.15 ohm, Z₁ = 0.1+j0.2 ohm and per phase impedance in the balanced Delta connected load, Z₁ = 12+j9 ohm. RMS value of source voltage is 200 volt. Phase sequence is as shown in the diagram. RMS value of current Ic= ampere Phase angle of le= degree RMS value of line voltage VCA = B JAB Inc ICAarrow_forward
- A balanced three-phase Delta connected voltage source supplies Delta connected three-phase symmetrical load through a three-phase line at 50 Hz as shown in the figure below. Please, answer the following using ZL=0.4+j 0.8 N and Zab = Zbc = Zca=10.3+j 14.1 N. A I a Zz Z. ca I 400 20° v +1 400Z-120° v Ic SOURCE LINÉ LOAD Part F: Calculate the reactive power of the three-phase Delta load in terms of VAr. 4002-240° varrow_forwardA 3-phase delta connected load is supplied by a 11/0.4 kV, star-delta connected transformer. The load impedances are Z1 = 20 + j0 ohms, Z2 = 10 – j5 ohms and Z3 = 15 + j10 ohms. Determine the line currents and also currents in the secondary windings of the transformersarrow_forwardThree 230 V generators form a delta connected source that is connected to a balanced load of ZL = 10 + j8 Q per phase as shown in Figure below. (a) Determine the value of IAC (b) What is the value of IbB? a A 230/120° 230/0° b B C 230-120°arrow_forward
- The plant capacity of a 3-phase generating station consists of two 8 MVA generators of reactance 14·5%each and one 4 MVA generator of reactance 9·5%. These are connected to a common bus-bar fromwhich loads are taken through a number of 3 MVA step-up transformers each having 4% reactance.Determine the MVA rating of the circuit breakers on (i) L.V. side and (ii) H.V. side. Reactances givenare based on the MVA of each equipment. [(i) 15·24 MVA (ii) 50·25 MVA]arrow_forward1. A balanced three-phase Y-source with Vph "E" V rms drives a Y-connected three-phase load with phase impedance ZA = " F" Q, ZB = "G" N, and Zc= "H" N. Calculate the line currents and total complex power delivered to the load. Assume that the neutrals are connected. E=230 F= 90 G= 9+j5 H= j90arrow_forwardThe Figure shows a balanced Y-A 3Ø circuit. The phase voltages of the Y-connected source are V, = 11020°, V, = 1102 - 120° and V. = 1102120°, Volts. The line impdedances are Z,=10+j5 Q each. The impedances of the A-connected load are ZA = 75+j255 N each. Determine: Line Currents, Phase Currents (load), Power drawn by the load. Ve ZA Vbarrow_forward
- 1. The following are the given for the circuit below: VRY = 220 cis 0°, VYB = 220 cis -120° and VBR = 220 cis -240°. IR = 10 cis 0°. The load is balanced and delta connected. Determine the: (a) Impedance per phase (b) Current per phase (c) Line currents. B R reellle relllle momm Y RY Iy IB ĪR B R ZBR VYB ZRYarrow_forwardThree single-phase transformers (ideal) are connected as shown in the figure below to supply a balanced 3-phase, 150 KVA, 600 VL load from primary 4.16 KVLL line. H1 X1 H2 X2 BALLANCED H1 X1 THREE PHAGE LOAD H2 X2 H1 X1 X2 (a) Draw (neatly) a phasor diagram showing the three, primary line-to-line voltages and the six secondary phase and line voltages. What is the phase relationship between the primary voltage VAB and the secondary voltage V12? Indicate on the phasor diagram:farrow_forwardestions:- 1. Identify unity power factor points on V-curves and comment why you will not get unity power factor at same It for vanous loads?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License