Theory and Design for Mechanical Measurements
6th Edition
ISBN: 9781118881279
Author: Richard S. Figliola, Donald E. Beasley
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 10, Problem 10.39P
An engineer has an application of water at 20 °C flowing through DN100, Schedule 40 pipe. Available is a Rosemount 8800D flanged vortex flow meter, which specifies a usable range of 6.86 to □ • • • 225 m /hr in liquids. Suppose it uses a proprietary shedder design (St = 0.19) with a characteristic shedder diameter d of 26 mm. What range of shedding frequency should be expected?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Series pipe ABCD consists of 10,000 ft of 20′′, 8000 ft of 16′′, and L ft of 12′′ (C = 120). What length L will make theABCD pipes equivalent to a 15′′ pipe, 16,500 ft long, C = 100? If the length of the 12′′ pipe from C to D were 3000 ft, whatflow (in mgd) would occur for a lost head of 135 ft from A to D? please include fbd
Use g=32.2 */sec2 (9.81 m/s2) and 60°F (16°C) water unless told to do otherwise.• Google schedule-40 pipe’s thickness at different nominal size to obtain the innerdiameter of the pipe for accurate determinaLon of flow velocity.• Must show your work to support your selecLon. Otherwise, no points will be given.• No peer discussion is allowed.. A cylindrical tank 5 ft high has a constant diameter of 4 ft is full of water. The tank has a hole2. A cylindrical tank 5 * high has a constant diameter of 4' is full of water. The tank has a holein its bo]om that measures 0.1ft^2. All losses are insignificant. How long will it take for the tankto empty? Note that you can NOT assume a staLc head and constant flow rate because thewater head in the tank decreases as the water flows out of the tank
(A) 35 sec(B) 70 sec(C) 105 sec(D) 140 sec
Recommend the low cost flow meter used in industries for measuring flow that provides negligible loss of head in the pipeline. Discuss its construction and working. A venturi tube of throat diameter 10 cm is placed in a pipe of diameter 20 cm. The volumetric flow rate through the venturi tube is 0.02 m3/ sec. [Given: viscosity of water = 10–3 Pas]. Determine the Reynolds number and the upstream to throat differential pressure developed.
Chapter 10 Solutions
Theory and Design for Mechanical Measurements
Ch. 10 - Prob. 10.1PCh. 10 - A 20-cm-i.d. pipe through which 10 °C air flows is...Ch. 10 - What is the best estimate of the pipe flow rate...Ch. 10 - A mercury-filled (S = 13.57) manometer is used in...Ch. 10 - A capacitance pressure transducer is used to...Ch. 10 - Estimate the expansion factor in measuring the...Ch. 10 - The Reynolds number of a fluid flowing through a...Ch. 10 - At what flow rate of 20 °C water through a 10-cm-...Ch. 10 - Water (25 °C) flows through a square-edged orifice...Ch. 10 - An orifice plate is installed to meter air flow in...
Ch. 10 - Determine the flow rate of 38 °C air through a...Ch. 10 - A square-edged orifice (p = 0.5) is used to meter...Ch. 10 - Size a suitable orifice plate to meter the steady...Ch. 10 - An in-line flow nozzle is to be used to measure...Ch. 10 - A cast venturi meter is to be used to meter the...Ch. 10 - For 120 ft3/m of 60 °F water flowing through a...Ch. 10 - Estimate the flow rate of water through a...Ch. 10 - A 2-in. (50.8 ram) diameter orifice plate is...Ch. 10 - In order to measure the flow rate ina2mx2mair...Ch. 10 - A flow nozzle is to be used at choked conditions...Ch. 10 - Compute the flow rate of 20 °C air through a 0.5-m...Ch. 10 - An ASME long radius nozzle (P = 0.5) is to be used...Ch. 10 - A square-edged orifice plate is selected to meter...Ch. 10 - Estimate the error contribution to the uncertainty...Ch. 10 - For Problem 10.24, suppose the air flow rate is 17...Ch. 10 - An application uses water flowing at up to...Ch. 10 - Dry air at a static pressure and temperature of...Ch. 10 - Dry air at a stagnation pressure and temperature...Ch. 10 - A sonic nozzle can be used to regulate flow rate...Ch. 10 - Select an appropriate range for a differential...Ch. 10 - From a vendor catalog or online site, select a...Ch. 10 - A vortex flow meter uses a shcdder having a...Ch. 10 - A thermal mass flow meter is used to meter 30 °C...Ch. 10 - Research available thermal mass flow meters...Ch. 10 - Fuel oil used in large sea vessels is known as...Ch. 10 - Estimate an uncertainty in the determined flow...Ch. 10 - A thermal mass flow meter is used to meter air in...Ch. 10 - A vortex meter is to use a shedder having a...Ch. 10 - An engineer has an application of water at 20 °C...Ch. 10 - The flow of air is measured to be 30 m3/min at 50...Ch. 10 - A 6 in. x 4 in. i.d. cast venturi is used to...Ch. 10 - A simple method to measure volume flow rate is to...Ch. 10 - In the problem 10.42, suppose volume can be...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 04: For the piping system, compute pressure at A, and mid pipe 2. If pipe (3) & pipe (4) havi equal discharge, and pipe (1) have the same properties of pipe (5). Neglect minor losses. (S F S) Pipe 1 L (m) Pipe 2 460 Pipe 3 300 Pipe 4 365 D (cm) Q (1/sec) 245 30 30 20 38 566 f PB (kPa) Pipe 1 0.027 500 Pipe 2 Pipe 3 rig 4. B Pipe 4 Pipe Sarrow_forwardQI/ A (300mm) diameter of pipe, if the discharge (90 L/sec), nozzle diameter (75mm) and pipe length from (1 to 2) was (100m) Determine the length of pipe from (2 to 3), and the pressure at point (2). (e=0.026mm, v =1.13* 10“ m²/sec). Fig(1). 6m 23m Fig.(1) Nozzlearrow_forward1-A steel discharge pipe with a roughness equal to 0.5 mm is 800 m long and pumps 265 m³ of water per hour at a temperature of 20°C. The pipe diameter is 25 cm. Calculate the head loss. Data: kinematic water viscosity equal to 10-6 NOTE: if necessary, use Moody's DiagramHelp?arrow_forward
- An oil and gas company want to measure the flow rate of the oil in a low head loss application. 1. Suggest a suitable flow measuring device 2. Explain its different parts and working principle. 3. Draw neat sketch and marks its parts. ( write by Keyboard three pages at least )arrow_forwardIt is desired to meter methanol at 20°C flowing through a5-in-diameter pipe. The expected flow rate is about 300gal/min. Two flowmeters are available: a venturi nozzle anda thin plate orifice, each with d = 2 in. The differential pressuregage on hand is most accurate at about 12–15 lbs/in2.Which meter is better for this job?arrow_forwardA particular flow meter allows the volumetric flow rate Q to be calculated from a measured pressure drop Δp. Theory predicts Q ∝ sqrt(Δp), and a calibration provides the following data: Q (m^3/min): 10, 20, 30, 40 Δp ( Pa): 1,000 , 4,271 , 8,900 , 16,023 What uncertainty in the measurement of Δp is required to yield an uncertainty of 0.25% in Q over the range of flow rates from 10 to 40 m3/min?arrow_forward
- Q3// A rotary filter is required for the filtration of a slurry to produce 10 m' in 3500 s, the pressure difference is a constant at 70 kN/m´ and 20% of the drum is submerged in the slurry. A sample was tested on a laboratory filter of area 0.023 m² to which it give filtrate at a constant rate of 0.0125 m/s. The pressure difference across the test filter increased from 14 kN/m? after 300 s to 28 kN/m² after 900 s. What are suitable diameter for the rotary filter. Assuming that the resistance of the cloth used is the same that on the test filter.arrow_forwardOn a single plot, plot three curves that show the relationship between the pressure generated by thepump as a function of flow rate of water at 20 °C through the three branches of the piping systemshown below. Delta P on y axis and flow rate on the x axis. The pressure range is 0 to 1 MPa. (Branches 1 and 3 are in the same plane; branch 2 is located 5 m above the other two branches. Pipe inner diameter: 0.0254 mPipe material: copperTypical mass flow rate of interest: 0.5 kg/sIgnore minor losses of tee's at points A and B and any features of branch 3Consider minor losses of two 90° elbows in branch 2arrow_forwardThe theoretical flowrate calculated for a venturi meter is 0.0001895 m3/s. The actual flowrate recorded using a stopwatch and volumetric container is 0.0001847 m3/s. Calculate the coefficient of discharge of the venturi meter. Answer: Next page page 9 Search for anythingarrow_forward
- Medium oil with kinematic viscosity 6.10x10^-6 m²/s, flows through a straight pipe at a rate of 6.0 Liters/sec. For Laminar flow conditions, what is the least diameter of the pipe. (Show the free body diagram) A. 0.79 mB. 0.66 mC. 0.70 mD. 0.60 mE. 0.64 marrow_forwardA 300 mm x 150 mm venturimeter is provided in a vertical pipeline carrying oil of specific gravity 0.9, flowing upward. The difference in elevation of the throat section and entrance section of the venturimeter is 300 mm. The differential U – tube manometer shows a gauge deflection of 250 mm.Calculate i) The discharge of oil ii) The pressure difference between entrance and Throat section. Take : coefficient of discharge of venturimeter is 0.98arrow_forwardUse g=32.2 */sec2 (9.81 m/s2) and 60°F (16°C) water unless told to do otherwise.• Google schedule-40 pipe’s thickness at different nominal size to obtain the innerdiameter of the pipe for accurate determinaLon of flow velocity.• Must show your work to support your selecLon. Otherwise, no points will be given.Water flows through a schedule-40 pipe that changes gradually in diameter from 6 in (154mm) at point A to 18 in (429 mm) at point B. The volumetric flow rate is 5.0 *3/sec (130 L/s). The respecLve pressures at points A and B are 10 psia (70 kPa) and 7 psia (48.3 kPa). All lossesare insignificant. What are the direcLon of flow and velocity at point A? (A) 3.2 */sec (1 m/s); from A to B(B) 25 */sec (7.0 m/s); from A to B(C) 3.2 */sec (1 m/s); from B to A(D) 25 */sec (7.5 m/s); from A to Barrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Intro to Compressible Flows — Lesson 1; Author: Ansys Learning;https://www.youtube.com/watch?v=OgR6j8TzA5Y;License: Standard Youtube License