Show that the instrument (systematic) uncertainty in an inclined tube manometer in Example 9.3 increases to 6.8 N/m2 as 0 goes to 90 degrees.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A U-tube manometer indicates a pressure drop of 10 in. water across in an air filter. The air is at 26 C and a pressure of 60 lbf/in2 :
(a) What is the pressure drop in lbf/in2 and in atm?
(b) What percentage of error is introduced if the density of the air in the manometer leads is neglected. (Air density = 1.168 kg/m3 ) (g =32.17 ft/s2)
A Prandtl tube (Pitot-static tube with C = 1) is used to measure the velocity of water. The
differential manometer reading is 10 mm of liquid column with a relative density of 10.
Assuming g = 9.8 m/s², the velocity of water (in m/s) is
3. Calculate a circular pressure tank volume and its uncertainty if the diameter, D,
is 1.5 m and the length, L, is 3 m and the measurement are given with bilateral
tolerance of±l cm.
2
2
ле
si +
Sy =
tolerance in diameter
tolerance in length
where Sp=
and Si =
3
3
D2
andV = ar²L=n-L
4
Chapter 9 Solutions
Theory and Design for Mechanical Measurements
Ch. 9 - Prob. 9.1PCh. 9 - 9.2 State the following pressures as absolute...Ch. 9 - A water-filled manometer is used to measure the...Ch. 9 - Prob. 9.4PCh. 9 - 9.5 The pressure differential across an orifice...Ch. 9 - Show that the static sensitivity of an inclined...Ch. 9 - Prob. 9.7PCh. 9 - Show that the instrument (systematic) uncertainty...Ch. 9 - A strain gauge, diaphragm pressure transducer...Ch. 9 - Select a practical fluid to use in a manometer to...
Ch. 9 - An air pressure over the 200- to 400-N/m2 range is...Ch. 9 - Calculate the design-stage uncertainty in...Ch. 9 - The pressure drop across a valve through which air...Ch. 9 - Estimate the sensitivity (pF/mm) of a capacitance...Ch. 9 - A diaphragm pressure transducer is calibrated...Ch. 9 - A diaphragm pressure transducer is coupled with a...Ch. 9 - Prob. 9.17PCh. 9 - A 2.0 mm thick circular steel diaphragm (Em = 200...Ch. 9 - Estimate the differential pressure limit for a...Ch. 9 - The pressure fluctuations in a pipe filled with...Ch. 9 - What is the sensitivity of a pitot-static tube...Ch. 9 - A pitot-static pressure probe inserted within a...Ch. 9 - A tall pitot-static tube is mounted through and...Ch. 9 - The pressure transmission line response equation...Ch. 9 - Prob. 9.26PCh. 9 - Prob. 9.28PCh. 9 - Compare the inertance of water in a 0.2-m-long...Ch. 9 - The output from a resting healthy human adult...Ch. 9 - Prob. 9.31PCh. 9 - A pressure drop of 213 Pa is measured between two...Ch. 9 - Wall pressure taps (e.g., Figs. 9.19 and 9.21) are...Ch. 9 - Prob. 9.34PCh. 9 - Prob. 9.35PCh. 9 - Determine the resolution of a manometer required...Ch. 9 - A long cylinder is placed into a wind tunnel and...Ch. 9 - Prob. 9.38PCh. 9 - Prob. 9.39PCh. 9 - What is the sound pressure in pascals if the...Ch. 9 - A 6-mm-diameter pitot-static tube is used as a...Ch. 9 - For the thermal anemometer in Figures 9.31 and...Ch. 9 - Determine the static sensitivity of the output...Ch. 9 - A laser Doppler anemometer setup in a dual-beam...Ch. 9 - A set of 5,000 measurements of velocity at a point...Ch. 9 - Aircraft airspeed is measured using a pitot...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The transducer specified in Table 1.1 is chosen to measurea nominal pressure of 500 cm H2O. The ambient temperature is expected to vary between 18 ∘C and 25 ∘C duringtests. Estimate the possible range (magnitude) of each listedelemental error affecting the measured pressure. How do I calculate the sensitivity error? The solution that was given: Sensitivity error(eK) = (±0.0025)(500 cm H2O)= ± 0.75 cm H2O = ± 0.00375 V My Question is, how do you obtain 0.75 since 0.0025 x 500 gives 1.25! please help. thanksarrow_forwardan automobile speedometer is graduated in 5 kmph increaments and has accuracy rated to be within 4% . estimate the 95% uncertainty in indicated speed at 90 kmph??arrow_forwardA 100 mm by 50 mm Venturi meter is installed in a 100 mm diameter pipe to measure the flow of a certain liquid (sp gr 1.20). A differential gage connected with the inlet and throat contains a substance (sp gr 1.5) in the lower part of the tube, the remainder of the tube being filled with the certain liquid. The difference in height of substance columns in the two legs of the tube is 75 cm. If the coefficient of the meter is 0.97, compute the actual discharge.arrow_forward
- The transducer specified in Table 1.1 is chosen to measurea nominal pressure of 500 cm H2O. The ambient temperature is expected to vary between 18 ∘C and 25 ∘C duringtests. Estimate the possible range (magnitude) of each listedelemental error affecting the measured pressure refering to the solution provided online, Sensitivity error(eK) = (±0.0025)(500 cm H2O)= ± 0.75 cm H2O = ± 0.00375 V how do you get 0.75?? shoud it not be 1.25? according the answer, for sensitivityarrow_forwardA thermometer having a time constant of 0.2 min is placed in a temperature bath, and after the thermometer comes to equilibrium with the bath, the temperature of the bath is increased linearly with time at a rate of l0 C/min. What is the difference between the indicated temperature and the bath temperature (a) 0.1 min, (b) 1.0 min after the change in temperature begins?arrow_forwardWhat should be the surface tension of a liquid if its density, which is 1.44 g/cc, is the same as that of the calibrating liquid? The displacements of the liquid and the calibrating liquid inside the capillary tube are both 0.5 cm. The surface tension of the calibrating liquid is 29.4509 dynes/cm.arrow_forward
- In a Measurement the Expected value is 10 V and the measured value is 71 V, Find O absolute eror Ea (ORelative error Er, (ii) Absolute accuracy Aa (iv) Relative Accuracy ) Absolute Error= (i)Relative error= (i) Absolute accuracy= (iv) Relative Accuracyarrow_forward1. To determine the dynamic viscosity of a liquid you take repeated measurements of the liquid density and kinematic viscosity. These data are summarized in the following table: Avg. measurement Total Uncertainty P 999 kg/m³ ±0.5% V 1.23 mm²/s ±0.01 mm²/s kg Ns What is the dynamic viscosity? Give dynamic viscosity in units of; which is the same as ms 2. Determine the absolute and relative uncertainties in the dynamic viscosity.arrow_forwardThe following table lists temperatures and specific volumes of water vapor at two pressures: p = 1.0 MPa p = 1.5 MPa T (°C) v(m³/kg) T (°C) v(m³/kg) 200 0.2060 200 0.1325 0.1483 0.1627 0.2275 240 280 240 280 0.2480 Data encountered in solving problems often do not fall exactly on the grid of values provided by property tables, and linear interpolation between adjacent table entries becomes necessary. Using the data provided here, estimate i. the specific volume at T = 240 °C, p = 1.25 MPa, in m³/kg the temperature at p = 1.5 MPa, v = 0.1555 m³/kg, in °C the specific volume at T = 220 °C, p = 1.4 MPa, in m³/kg ii. iii. 11.arrow_forward
- An inclined tube manometer measures the gauge pressure ps of a system S . The reservoir and tube diameters of the manometer are 50 mm and 5 mmrespectively. The inclination angle of the tube is 30°. What will be the percentage error in measuring pS if the reservoir deflection is neglected.arrow_forward18. Find the gauge readings at A and B in Fig. 2.51. [Ans. 17.39 kN/m² (vacuum), 12.61 kN/m²] Mercury vapour Mercury (S = 13.6) -Closed 0.6 m 1.5 m Fig. 2.51 Air Oil (S=0.8) Water A 0.2 m Barrow_forwardPA Prandtl tube (Pitot-static tube with C = 1) is %3D used to measure the velocity of water. The differential manometer reading is 10 mm of liquid column with a relative density of 10. Assuming g 9.8 m/s?, the velocity of water (in m/s) isarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
8.01x - Lect 27 - Fluid Mechanics, Hydrostatics, Pascal's Principle, Atmosph. Pressure; Author: Lectures by Walter Lewin. They will make you ♥ Physics.;https://www.youtube.com/watch?v=O_HQklhIlwQ;License: Standard YouTube License, CC-BY
Dynamics of Fluid Flow - Introduction; Author: Tutorials Point (India) Ltd.;https://www.youtube.com/watch?v=djx9jlkYAt4;License: Standard Youtube License