Textbook Question
Chapter 26, Problem 8R
Circle the correct answer from the following statements:
- a. Smoke alarms installed in new one- and two-family homes must be interconnected so that if any one of them is triggered, all other alarms will also sound off.
- b. Smoke alarms installed in new one- and two-family homes are not permitted to be interconnected so that each alarm will operate independently of all other alarms in the home.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
TYPE OF APPLIANCES: AIRCONDITION
what type of detectors are present in the schematic diagram of the appliance and kinldy discuss the function, and operation of the detector. Kindly include descriptions, schematic diagrams, technical specifications.
Those employees who physically lock or tag out equipment for
servicing or maintenance:
Are always the people who normally operate the equip-
ment.
Are affected employees.
Are authorized employees.
Do not need training.
a.
b.
C.
d.
Lockout locks:
Can be used to lock tool boxes, storage sheds, etc.
Can be used only for lockout purposes.
a.
b.
C.
Are provided by the equipment manufacturer.
d.
Must be bright orange in color.
Authorized employees must be trained:
To recognize hazardous energy sources, and to know the
type and magnitude of the hazardous energy sources.
b.
a.
To perform the lockout/tagout procedure.
When an audit shows deficiencies with the procedure.
C.
d.
All of the above.
When authorized employees perform a shutriown, they must:
Notify all affected employees that they are starting a lockout
procedure.
b.
a.
Locate all energy sources that power the equipment.
C.
Follow the procedures to shut down each machine.
All of the above.
d.
If several people are needed to work on a…
Question 3:
Suppose an engineer designed a fire alarm system for a large warehouse, with multiple
pushbutton switches connected to a single alarm siren:
Siren
Actuating any of the normally-open switches results in the alarm sounding. So far, so good.
Now, suppose that one of the wires connecting one side of several switches to the rest of
the circuit breaks open. What will the result of this failure be?
Siren
break!
Chapter 26 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 26 - In your own words, explain the terms alarm and...Ch. 26 - The requirements for household fire alarm systems...Ch. 26 - Do heat alarms and carbon monoxide alarms take the...Ch. 26 - Name two basic ways that smoke alarms are powered.Ch. 26 - Name the two types of smoke alarms.Ch. 26 - List the absolute minimum level of smoke alarm...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Prob. 10R
Ch. 26 - Prob. 11RCh. 26 - An important but often overlooked requirement in...Ch. 26 - Carbon monoxide is ____________, and is...Ch. 26 - Circle the correct answer from the following...Ch. 26 - The wiring of more complex household fire alarm...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Circle the correct answer from the following...Ch. 26 - Fire alarm cable generally used in more complex...Ch. 26 - When installing a fire alarm system or a complete...Ch. 26 - Residential sprinkler fire protection systems are...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Circle the correct answer from the following statements: a. Always connect a fire alarm circuit or system to a power supply that has ground-fault circuit interrupter (GFCI) protection. b. Never connect a fire alarm circuit or system to a power supply that has ground-fault circuit interrupter (GFCI) protection. c. It makes no difference whether the branch circuit is GFCI or AFCI protected because the alarms are required to have battery backup power. In the event of a loss of power for whatever reason, the alarms would still be operative.arrow_forwardList the rooms and/or areas in a newly constructed single-family residence where arc-fault circuit-interrupter (AFCI) protection is required by the NEC.arrow_forwardThe requirements for household fire alarm systems are found in what NFPA Code and in what chapter of this Code?arrow_forward
- The following problems pertain to luminaires in clothes closets. a. Does the Code permit bare incandescent lamps to be installed in porcelain key-less or porcelain pull-chain lampholders? ________________ b. Does the Code permit bare fluorescent lamp luminaires to be installed? ________________ c. Does the Code permit pendant lampholders to be installed? ________________ d. What is the minimum clearance from the storage area to surface-mounted incandescent luminaires? ________________ e. What is the minimum clearance from the storage area to surface-mounted fluorescent luminaires? ________________ f. What is the minimum distance between recessed incandescent or recessed fluorescent luminaires and the storage area? ________________ g. Define the storage area. ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ h. If a clothes hanging rod is installed where there is access from both sides, such as might be found in a large walk-in clothes closet, define the storage area under that rod. ___________________________________ ___________________________________arrow_forward2. When working on a high - voltage system , it is best to keep anyone who is not part of the ser vice away from you and the car by creating a buffer zone around the car . Technician A makes sure the outside edges of the zone are at least one foot away from the car . Technician B places B orange cones to define the outer boundaries of the zone. Who is correct ?arrow_forwardThe easiest place to install an ammeter into a stepper motor driver/motor circuit for system diagnostics is to attach the meter in series with the driver’s power supply lead. remove a fuse and place the meter leads across the fuse clips. disconnect a motor lead and attach the meter in series with that lead. connect the meter across the center tap and phase leads of the motor.arrow_forward
- The protective devices, such as ground wires, lightning arrestors, circuit breakers, relays are used to: Select one: a. step up the voltage. O b. Protect equipment and devices of the power system. O c. None of the above O d. step down the voltage.arrow_forwardGive me about ten examples of electrical code violations in maintenance and repair. Hopefully the explanation is detailed and better if there is a picture with references.arrow_forwardFour electricians are discussing wiring under raised floors in information technology equipment rooms. Electrician A says that wiring under the raised floor requires fire-resistant walls, floors, and ceilings between other occupancies. Electrician B says that wiring under the raised floor requires fire resistant halfway up the walls and floors between other occupancies. Electrician C says that the room must employ a disconnecting means that removes half of the power to all equipment in the room. Electrician D says that a disconnecting means isn't necessary for the room. Which of the following statements is correct? A. Electrician B is correct. B. Electrician D is correct. C. Electrician A is correct. D. Electrician C is correct.arrow_forward
- List the absolute minimum level of smoke alarm protection in a new one-family dwelling.arrow_forward(b) An employee is working on a ladder and the ladder seems to collapse. The employee falls off the ladder and breaks arm. The investigation reveals the following details: • Employee had worked seven 12-hour shifts in a row. • Accident happened at end of shift. • Employee was standing on the top step of the ladder (an unsafe action). The employee was approximately 10 feet above floor level. No fall arrest or restraint system was used. • A ladder inspection policy is in place, but there is no evidence that the ladder has ever been inspected. Investigation reveals the ladder was damaged and did not provide a stable working platform in any environment. • Interview with the facility manager reveals that he did not inspect the ladder when it was due for inspection. He was aware that the ladder needed to be inspected. (i) Examine either accident investigation is required or not. (ii) Discover SIX (6) factors and possible causes affecting the incidences. (iii) Explain the root cause of the…arrow_forwardDo heat alarms and carbon monoxide alarms take the place of smoke alarms? Explain.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License