A combined gas–steam power cycle uses a simple gas turbine for the topping cycle and simple Rankine cycle for the bottoming cycle. Atmospheric air enters the gas turbine at 101 kPa and 20°C, and the maximum gas cycle temperature is 1100°C. The compressor pressure ratio is 8; the compressor isentropic efficiency is 85 percent; and the gas turbine isentropic efficiency is 90 percent. The gas stream leaves the heat exchanger at the saturation temperature of the steam flowing through the heat exchanger. Steam flows through the heat exchanger with a pressure of 6000 kPa and leaves at 320°C. The steam-cycle condenser operates at 20 kPa, and the isentropic efficiency of the steam turbine is 90 percent. Determine the mass flow rate of air through the air compressor required for this system to produce 100 MW of power. Use constant specific heats for air at room temperature.
Want to see the full answer?
Check out a sample textbook solutionChapter 10 Solutions
Thermodynamics: An Engineering Approach
Additional Engineering Textbook Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Applied Statics and Strength of Materials (6th Edition)
Fundamentals of Heat and Mass Transfer
Vector Mechanics for Engineers: Statics, 11th Edition
Fundamentals Of Thermodynamics
Vector Mechanics for Engineers: Statics and Dynamics
- An ideal reheat Rankine cycle with water as the working fluid operates the inlet of the high-pressure turbine at 7000 kPa and 450°C, the inlet of the low-pressure turbine at 500 kPa and 500°C, and the condenser at 10 kPa. Determine the mass flow rate through the boiler needed for this system to produce a net 5000 kW of power and the thermal efficiency of the cycle. Use steam tables. kg/s. The mass flow rate through the boiler needed for this system to produce a net 5000 kW of power is The thermal efficiency is %.arrow_forwardA simple Rankine cycle uses water as the working fluid. The boiler operates at 6000 kPa and the condenser at 50 kPa. At the entrance to the turbine, the temperature is 450°C. The isentropic efficiency of the turbine is 94 percent, pressure and pump losses are negligible, and the water leaving the condenser is subcooled by 6.3°C. The boiler is sized for a mass flow rate of 19 kg/s. Determine the rate at which heat is added in the boiler, the power required to operate the pumps, the net power produced by the cycle, and the thermal efficiency. Use steam tables. The rate at which heat is added in the boiler is 4192.12 kW. The power required to operate the pumps is 59354.47 kW. The net power produced by the cycle is -55162.35 ✪ kW. The thermal efficiency of the cycle is 13.16 %.arrow_forwardHeat recovery steam generator joint between gas and steam turbine in combined cycle power plant. Air enters the compressor at 300 K and compressor pressure ratio is 11, turbine inlet temperature is1100 K. The combustion gases leaving the gas turbine are used to heat the steam at 5 MPa to 350°C in a heat recovery steam generator (HRSG). The combustion gases leave the HRSG at 420 K. An open feedwater heater incorporated with the steam cycle operates at a pressure of 0.8 MPa. The condenser pressure is 10 kPa. Assuming isentropic efficiencies of 100 percent for the pump, 82 percent for the compressor, and 86 percent for the gas and steam turbines, the combined gas-steam power plant that has a net power output of 280 MW determine (a) the mass flow rate ratio of air to steam, (b) the required rate of heat input in the combustion chamber, and (c) the thermal efficiency of the combined cycle.arrow_forward
- No 1 A Rankine cycle using superheat and reheat applications. Steam enters the stage 1 turbine at 8 MPa and a temperature of 480°C and expands at a pressure of 0.7 MPa. The steam is then reheated to a temperature of 440°C before entering the stage 2 turbine, where the steam expands in the condenser at a pressure of 0.008 MPa. The net power generated is 100 MW. No2 Using the data in number 1 above plus other data, namely each turbine has the same isentrapic efficiency of 85%, calculate the thermal efficiency of the cycle P.s Answer the number 2, number 1 just reference to answer number 2,thxarrow_forwardExample: Consider the combined gas-steam power cycle. The topping cycle is a gas-turbine cycle that has a pressure ratio of 8. Air enters the compressor at 300 K and the turbine at 1300 K. The isentropic efficiency of the compressor is 80 percent, and that of the gas turbine is 85 percent. The bottoming cycle is a simple ideal Rankine cycle operating between the pressure limits of 7 MPa and 5 kPa. Steam is heated in a heat exchanger by the exhaust gases to a temperature of 500°C. The exhaust gases leave the heat exchanger at 450 K. Lec. (7) T, KA Determine (a) the ratio of the mass flow rates of the steam and the combustion gases and (b) the thermal efficiency of the combined cycle. 1300 450 300 5' 7 MPa Power Plant 5 kPa 500°C 7 MPa Dr. Omar M. Ali 4arrow_forwardRefrigerant-134a is used as the working fluid in a simple ideal Rankine cycle which operates the boiler at 2000 kPa and the condenser at 24C. The mixture at the exit of the turbine has a quality of 93 percent. Determine the turbine inlet temperature, the cycle thermal efficiency, and the back-work ratio of this cycle.arrow_forward
- The net work output and the thermal efficiency for the Carnot and the simple ideal Rankine cycles with steam as the working fluid are to be calculated and compared. Steam enters the turbine in both cases at 5 MPa as a saturated vapor, and the condenser pressure is 50 kPa. In the Rankine cycle, the condenser exit state is saturated liquid and in the Carnot cycle, the boiler inlet state is saturated liquid. Draw the T-s diagrams for both cycles.arrow_forwardA simple Rankine cycle uses water as a working fluid. The boiler operates at 6000 kPa and the condenser at 50 kPa. At the entrance to the turbine, the temperature is 450 degrees celcius. The isentropic efficiency to the turbine is 90%, pressure and pump losses are negligible, and the water leaving the condenser is subcooled to 6.32 degrees celcius. The boiler is sized for the mass flow rate of 20 kg/s. Determine: a) The rate at which heat is added in the boiler b) The power required to operate the pumps c) The net power produced by and thermal efficiency of the cyclearrow_forwardThe first steam power plant operates on an ideal reheat Rankine cycle. Steam enters the first turbine at 8 MPa and 500 C and leaves at 3 MPa. Steam is then reheated at a constant pressure to 500 C before it expands to 20 kPa in the low-pressure turbine. Assuming that heat is being added to the boiler from a high temperature source at 1800 K and the condenser is transferring heat to a temperature sink at 300 K. 1. Investigate the effect of changing pump efficiency on the overall thermal efficiency of the thermodynamics cycle (Hint: You will assume different values for the isentropic pump efficiency such as: 70%, 80%, 90%, 95%, and 100%, then observe how it will change the thermal efficiency of the cycle). Representing the results in a plot is recommended.arrow_forward
- 4. Consider a simple ideal Rankine cycle. The pressure of the boiler and the condenser are 3 Mpa and 10 kPa respectively. The temperature of the steam entering the turbine is 350°C, and the quality of mixture leaving the turbine is 0.8. Calculate the back work ratio, in %. 0.4% - 0.5% · 0.3 % - 0.6%arrow_forwardIn a Rankine cycle with reheating, the steam leaves the boiler at 2.5 MPa and 600 ºC and enters the high pressure turbine where it expands to a pressure of 1 MPa to be then subjected to a reheating process from where it leaves at 1 MPa and 600 ° C. The steam at these conditions enters the low pressure turbine and expands up to the condenser pressure of 50 kPa. The heat that is extracted in the condenser is 1500 kJ / s. If the adiabatic efficiency of the turbines and the pump is 95%, determine the total heat flow in kJ / s delivered to the boiler.arrow_forwardThe net power of a steam power plant operating on the simple ideal Rankine cycle is 30.5 MW. Water vapor enters the turbine at a pressure of 7 MPa and a temperature of 500 °C, and expands to the pressure of the 10 kShare condenser in the turbine. In the steam condenser, it is cooled and condensed with water supplied from a lake. The flow rate of the lake water is 1950 kg/s. Take the adiabatic efficiency of the pump and turbine by 87%. Show the cycle in the T-sdiagram. Csu=4.18kJ/kg°C a) The thermal efficiency of the cycle,b) The flow of steam circulating in the circuit,c)Calculate the temperature rise of the cooling water.arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY