6-145 The drinking water needs of a production facility with 20 employees is to be met by a bubbler type water foun- tain. The refrigerated water fountain is to cool water from 22 to 8°C and supply cold water at a rate of 0.4 L per hour per person. Heat is transferred to the reservoir from the surround- ings at 25°C at a rate of 45 W. If the COP of the refrigeration system is 2.9, determine the size of the compressor, in W, that will be suitable for the refrigeration system of this water cooler.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter45: Domestic Refrigerators And Freezers
Section: Chapter Questions
Problem 12RQ: Refrigerators currently being manufactured in the United States are using______as their refrigerant.
icon
Related questions
Question

I need some help with conceptualizing the problem. Here there is a refrigeration cycle, I assume that the water is the low reservoir and the air is the high reservoir. To calculate the heat transfer from the water (Q_L) we also need to consider the heat transfer from the surroundings to the water reservoir. So then our Q_L becomes (Q_L = Q_cooling + Q_transfer). This is correct way to think about the problem?

6-145 The drinking water needs of a production facility
with 20 employees is to be met by a bubbler type water foun-
tain. The refrigerated water fountain is to cool water from
22 to 8°C and supply cold water at a rate of 0.4 L per hour per
person. Heat is transferred to the reservoir from the surround-
ings at 25°C at a rate of 45 W. If the COP of the refrigeration
system is 2.9, determine the size of the compressor, in W, that
will be suitable for the refrigeration system of this water
cooler.
Transcribed Image Text:6-145 The drinking water needs of a production facility with 20 employees is to be met by a bubbler type water foun- tain. The refrigerated water fountain is to cool water from 22 to 8°C and supply cold water at a rate of 0.4 L per hour per person. Heat is transferred to the reservoir from the surround- ings at 25°C at a rate of 45 W. If the COP of the refrigeration system is 2.9, determine the size of the compressor, in W, that will be suitable for the refrigeration system of this water cooler.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Power Plant Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning