Question
Chapter 6, Problem 6.64P
To determine
The optimal dispatch values of P1and P2for the given load, incremental operating cost and the total operating cost.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
in distribution transformers; What is 30 degrees phase shift in delta-star connection? What are the disadvantages? (can you explain with drawing?)
In
the
medium
and large transformers,
the
total
copper
losses should be
A2
% of the rated output.
(a) 0.7 to 0.9
(b) 0.5 to 2
(c) 0.2 to 0.6
(d) 0.4 to 1
In DC machines,
provides the magnetic path as well as the
In large transformers, the total copper losses may vary from
the rated output.
% of
0.8 to 1.5
0.2 to 0.6
0.5 to 1
0.4 to 1
Chapter 6 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 6 - For a set of linear algebraic equations in matrix...Ch. 6 - For an NN square matrix A, in (N1) steps, the...Ch. 6 - Prob. 6.9MCQCh. 6 - Prob. 6.11MCQCh. 6 - Using Gauss elimination, solve the following...Ch. 6 - Prob. 6.9PCh. 6 - Determine the bus admittance matrix (Ybus) for the...Ch. 6 - Prob. 6.34PCh. 6 - Prob. 6.37PCh. 6 - Prob. 6.38P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Describe the On-load and No-load in transformersarrow_forwardwhat is the definition of zero sequence impedance in a transformers? And what is the benefit of this check in transformers?arrow_forwardTo convert a per-unit impedance from old to new base values, the equation to be used is Zp.u.new=Zp.u.old(VbaseoldVbasenew)2(SbasenewSbaseold)Zp.u.new=Zp.u.old(VbaseoldVbasenew)2(SbasenewSbaseold)Zp.u.new=Zp.u.old(VbaseoldVbasenew)2(SbasenewSbaseold)arrow_forward
- Consider three ideal single-phase transformers (with a voltage gain of ) put together as three-phase bank as shown in Figure 3.35. Assuming positive-sequence voltages for Va,Vb, and Vc find Va,Vb, and VC. in terms of Va,Vb, and Vc, respectively. (a) Would such relationships hold for the line voltages as well? (b) Looking into the current relationships, express IaIb and Ic in terms of IaIb and Ic respectively. (C) Let S and S be the per-phase complex power output and input. respectively. Find S in terms of S.arrow_forwardFor large power transformers rated more than 500 kVA, the winding resistances, which are small compared with the leakage reactances, can often be neglected. (a) True (b) Falsearrow_forwardThe per-unit equivalent circuit of two transformers Ta and Tb connected in parallel, with the same nominal voltage ratio and the same reactan of 0.1 per unit on the same base, is shown in Figure 3.43. Transformer Tb has a voltage-magnitude step-up toward the load of 1.05 times that of Ta (that is, the tap on the secondary winding of Tb is set to 1.05). The load is represented by 0.8+j0.6 per unit at a voltage V2=1.0/0 per unit. Determine the complex power in per unit transmitted to the load through each transformer, comment on how the transformers share the real and reactive powers.arrow_forward
- A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a balanced load of three 1, Y-connected resistors. Choosing a base of 90MVA,66kV for the high-voltage side of the three-phase transformer. spify the base for the low-voltage side. Compute the per-unit resistance of the load on the base for the low-voltage side. Also, determine the load resistance in ohms referred to the high-voltage side and the per-unit value on the chosen base.arrow_forwardThree single-phase two-winding transformers, each rated 25MVA,54.2/5.42kV, are connected to form a three-phase Y- bank with a balanced Y-connected resistive load of 0.6 per phase on the low-voltage side. By choosing a base of 75 MVA (three phase) and 94 kV (line-to-line) for the high-voltage side of the transformer bank, specify the base quantities for the low-voltage side. Determine the per-unit resistance of the load on the base for the low-voltage side. Then determine the load resistance RL in ohms referred to the high-voltage side and the per-unit value of this load resistance on the chosen base.arrow_forwardWhat is load line and what is duty cycle?arrow_forward
- 6.1. A power system network is shown in Figure 47. The generators at buses 1 and 2 are represented by their equivalent current sources with their reactances in per unit on a 100-MVA base. The lines are represented by n model where series reactances and shunt reactances are also expressed in per unit on a 100 MVA base. The loads at buses 3 and 4 are expressed in MW and Mvar. (a) Assuming a voltage magnitude of 1.0 per unit at buses 3 and 4, convert the loads to per unit impedances. Convert network impedances to admittances and obtain the bus admittance matrix by inspection. j0.25 50.25 -j4 j0.4 j0.1 j0.16 j0.2 -j4+3 4 S3 -j4 S4 FIGURE 47 One-line diagram for Problem 6.1. 100 MW +j25 Mvar 200 MW +j50 Mvararrow_forwardThe dangers and failure in it and How can we be protect from these dangers and defects of Three-phase distribution transformers?arrow_forwardWhat is load curvearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning