Interpretation:
The signal-to-noise ratio is to be stated.
Concept introduction:
The signal and noise are two components of instrument measurement. One component is the signal, which carries information that is of interest to scientists and another component is noise, which is the unwanted fluctuations of signals.
Answer to Problem 5.7QAP
The signal-to-noise ratio is
Explanation of Solution
The magnitude of signal is denoted by
The expression for the mean of the measurements is:
Here, the total number of measurement is
Substitute
The expression for the standard deviation is:
Substitute
The expression for the signal to noise ratio is:
Substitute
(b)
Interpretation:
The number of measurements required to obtain a
Concept introduction:
The signal and noise are two components of instrument measurement. One component is the signal, which carries information that is of interest to scientists and another component is noise, which is the unwanted fluctuations of signals. For
Answer to Problem 5.7QAP
The number of measurement required to obtain a
Explanation of Solution
The expression for
Here, the signal to noise at initial point is
Substitute
Substitute
Want to see more full solutions like this?
Chapter 5 Solutions
Principles of Instrumental Analysis, 6th Edition
- Identify and provide either an concise explanation of the concept signal-to-noise ratio (SNR), in the context of chemical analysis.arrow_forward12 Considering the micrograph belongs to material as single phase alloy; Calculate the magnification by considering the scale bar as 1 cm. * •Sur 100μmarrow_forwardIn Spectrophotometric Determination of a Metal, how do you compute or get for the Corrected Absorbance (AU). What are the steps?arrow_forward
- A 10.00 g sample containing an analyte was transferred to a 250 mL volumetric flask and diluted to volume. When a 10.00 mL aliquot of the resulting solution was diluted to 25.00 mL it was found to give a signal of 0.235 (arbitrary units). A second 10.00 mL aliquot was spiked with 10.00 mL of a 1.00 ppm standard solution of the analyte and diluted to 25.00 mL. The signal for the spiked sample was found to be 0.502. Calculate the weight percent of analyte in the original sample.arrow_forward1. A compound has a molar absorptivity of 3.031 x 10° L cm1 mol1. If a 15.00 mm-length cell is used to hold the sample, and a transmittance of 19.53 % is measured, what is the molarity of the compound in solution?arrow_forwardA series of eight absorbance measurements using an atomic absorption spectrophotometer are as follows: 0.855, 0.836, 0.848, 0.870, 0.859, 0.841, 0.861, and 0.852. According to the instrument manufacturer, the precision of the absorbance measurements using this instrument should not exceed 1% relative standard deviation. Does it in this case?arrow_forward
- The following data were obtained for repetitive mass measurements of 1.004-g standard mass on a top-loading balance: 1.002, 1.000, 0.997, 1.004, 1.003, 1.001, 1.005, 0.999, 1.007. a. assuming the noise is random, calculate the signal-to-noise ratio for the balance. b. How many measurements would have to be averaged to obtain a S/N of 500?arrow_forwardChemistry Questionarrow_forwardAn absorption measurement with a 1 cm path length yields a reading of 0.004 absorbance units with a noise of 0.001 absorbance units and a mean noise reading of 0 for 10 scans averaged together. Assuming the noise for a single scan does not change if the path length is increased to 6 cm and the number of scans is increase to 100, what is the signal to noise of the new measurement.arrow_forward
- (B) A 0.05 mM solution of DCPIP was placed in a 1 cm spectrophotometer cuvette and a beam of light at 600nm was passed through the cuvette. The extinction coefficient for DCPIP is 3500 L/mole/cm under the specific conditions used. What proportion (as a percentage) of light would emerge from the other side of the cuvette?arrow_forwardThe molar absorptivity for aqueous solutions of phenol at 211 nm is 6.17 × 103 L cm-1 mol-1. Calculate the permissible range of phenol concentrations if the transmittance is to be less than 85% and greater than 7% when the measurements are made in 1.00-cm cells.arrow_forwardThe drug pentobarbital is a sedative. It was extracted from a urine sample during a particular ultraviolet-visible spectrophotometric forensic analysis procedure. The extraction solvent was evaporated and the residue reconstituted in a small volume of the transparent solvent methanol. The pentobarbital solution thus obtained had a percent transmittance (%T) of 91 at the relevant wavelength of maximum absorbance. If the urine analyte concentration were halved, what would its percent transmittance be? (You may assume that the Beer-Lambert law holds). Can you show all the steps of the solutionarrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning