Theory and Design for Mechanical Measurements
6th Edition
ISBN: 9781118881279
Author: Richard S. Figliola, Donald E. Beasley
Publisher: WILEY
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
thumb_up100%
Chapter 4, Problem 4.41P
How many independent random measurements of a time-dependent acceleration signal obtained from a vibrating vehicle under fixed operating conditions would lead to a confidence interval about the mean of ±0.5 g, if the standard deviation of the signal is expected to be 1 g?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
compute the 95 confidence intervals for the inventory of a series of 12 replication of the simulation of a system, where the VERAGE INVENtory is 1000 units and sample standard deviation is 38
The "spring-like effect" in a golf club could be determined by measuring the coeffi cient of restitution (the ratio of the outbound velocity to the
inbound velocity of a golf ball fired at the clubhead). Twelve randomly selected drivers produced by two clubmakers are tested and the
coefficient of restitution measured. The data follow:
Club 1: 0.8406, 0.8104, 0.8234, 0.8198, 0.8235, 0.8562, 0.8123, 0.7976, 0.8184, 0.8265, 0.7773, 0.7871
Club 2: 0.8305, 0.7905, 0.8352, 0.8380, 0.8145, 0.8465, 0.8244, 0.8014, 0.8309, 0.8405, 0.8256, 0.8476
Test the hypothesis that both brands of ball have equal mean overall distance. Use a = 0.05 and assume equal variances. Answer the following
questions regarding the t-test.
1. How many degrees-of-freedom are there in this problem (needed for finding the critical t-
values).
2. What is the absolute values of the critical t-value for this problem? We are using a two-
tailed t-test with a significance level of 5%. (use four significant figures)
3. What is…
A temperature measurement system is composed of a sensor and a readout device. The readout device has a claimed accuracy of 0.6 °C with a resolution of 0.1 °C. The sensor has an off-the-shelf limit of error of 0.5 °C. Estimate a design-stage uncertainty in the temperature indicated by this combination.
A displacement transducer has the following specifications:
Linearity error:±0.25% reading
Drift:±0.05%/°C reading Sensitivity error: ±0.25% reading
Excitation: 10-25 V
Output: dc 0-5Vdc
Range: 0-5 cm
The transducer output is to be indicated on a voltme- ter having a stated accuracy of 0:1% reading with a resolution of 10 μV. The system is to be used at room temperature, which can vary by 10 °C. Estimate an uncertainty in a nominal displacement of 2 cm at the design stage. Assume 95% confidence.
Chapter 4 Solutions
Theory and Design for Mechanical Measurements
Ch. 4 - Prob. 4.1PCh. 4 - Prob. 4.2PCh. 4 - At a fixed operating setting, the pressure in a...Ch. 4 - Consider the toss of four coins. There are 24...Ch. 4 - As a game, slide a matchbook across a table,...Ch. 4 - Prob. 4.6PCh. 4 - A student conducts a lab exercise to calculate the...Ch. 4 - From a large database, the Highway Patrol...Ch. 4 - Prob. 4.9PCh. 4 - Prob. 4.10P
Ch. 4 - Prob. 4.11PCh. 4 - Prob. 4.12PCh. 4 - Prob. 4.13PCh. 4 - Prob. 4.14PCh. 4 - Prob. 4.15PCh. 4 - From 19 measurements of a pressure controller, the...Ch. 4 - From 19 measurements of a pressure controller, the...Ch. 4 - When the parameters of a population are known, the...Ch. 4 - A professor grades students on a normal curve. For...Ch. 4 - Prob. 4.20PCh. 4 - 4.21 An automotive manufacturer removes the...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - A sampling of 409 motor shafts from a very large...Ch. 4 - During the course of a motor test, the motor rpm...Ch. 4 - A baich of rivets is tested for shear strength. A...Ch. 4 - Three independent sets of data are collected front...Ch. 4 - Prob. 4.28PCh. 4 - 4.29 An engineer measures the diameter of 20 tubes...Ch. 4 - Prob. 4.30PCh. 4 - For Problems 4.30 through 4.36. itwould be helpful...Ch. 4 - For Problems 4.30 through 4.36. itwould be helpful...Ch. 4 - For Problems 4.30 through 4.36. itwould be helpful...Ch. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - A manufacturer of general aircraft dry vacuum...Ch. 4 - Strength tests made on a batch of cold-drawn steel...Ch. 4 - 4.39 Determine the one-sided 95 th-percentile of...Ch. 4 - 4.40 The manufacturer of an electrical fuse claims...Ch. 4 - How many independent random measurements of a...Ch. 4 - Based on 51 measurements of a time-dependent...Ch. 4 - 4.43 Estimate the probability with which an...Ch. 4 - Prob. 4.44PCh. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - 4.48 A cantilever is loaded at its tip. Tip...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - A transducer is used to indicate the pressure of a...Ch. 4 - An engineer takes water samples from 15 lakes in...Ch. 4 - A random sample of 51 aircraft rivets is taken...Ch. 4 - Prob. 4.54PCh. 4 - Estimate the p-value for N = 16. t = 1.798...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A transducer's certificate of calibration (excerpt below) identifies two instrument errors with uncertainties at 95% confidence over it range. Resolution Range Linearity error Hysteresis error 0.25 N 0 to 200 N Within 0.2 N over range Within 0.3 N over range 1. Estimate the instrument design-stage uncertainty. 2. What is the instrument standard uncertainty?arrow_forwardQ.46 Robot Ltd. wishes to maintain enough safety stock during the lead time period between starting a new production run and its completion such that the probability of satisfying the customer demand during the lead time period is 95%. The lead time period is 5 days and daily customer demand can be assumed to follow the Gaussian (normal) distribution with mean 50 units and a standard deviation of 10 units. Using o-(0.95) = 1.64, where o represents the cumulative distribution function of the standard normal random variable, the amount of safety stock that must be maintained by Robot Ltd. to achieve this demand fulfilment probability for the lead time period is units. [Round off to two decimal places]arrow_forward26. One of the joints of a certain industrial robot has a type L joint with a range of 1.3 m. The bit storage capacity of the robot controller is 25 bits for this joint. The mechanical errors form a normally distributed random variable about a given taught point. The mean of the distribution is zero and the standard deviation is 0.08 mm in the direction of the output link of the joint. Determine the control resolution (CR), accuracy, and repeatability for this robot joint.arrow_forward
- As an engineer working for a water bottling company, you collect the following data in order to test the performance of the bottling systems. Assume normal distribution. Milliliters of Water in the Bottle Frequency 485 490 milliliters 495 500 505 510 515 What is the mean (in milliliters)? milliliters What is the standard deviation (in milliliters)? What is the z value corresponding to 490 milliliters? Z = 6 12 20 33 18 11 00 8arrow_forwardA special sensor is designed to sense the percent vapor present in a liquid vapor mixture. If during a static calibration the sensor indicates 80 units when in contact with 100% liquid,0 units with 100% vapor ,and 40units with a 50:50% mixture,determine the static sensitivity of the sensorarrow_forwardA thermocouple was used to measure the temperature. Over the range of temperatures expected in the experiment, a linear regression analysis was performed for the temperature as a function of voltage. The best-fit equation was T = (-0.008563 + 220*V), where V is the thermocouple voltage. The voltage was fed into a 11-bit A/D converter with a voltage range of -8 V to 8 V. Determine the measurement resolution (in °C) due to the ADC? O 0.851 None O 3.113 1.710 0.393 4.960 1.144 O 3.797arrow_forward
- Areas Under the Standard Normal Curve-The Values Were Generated Using the Standard Normal Distribution Function of Excel Note that the standard normal curve is symmetrical about the mean. z 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12 1 0.95 0.96 0.97 0.98 0.99 1.01 1.02 1.03 1.04 1.05 Mean - 0 1.06 1.07 1.08 1.09 A 0.0000 0.0040 0.0080 0.0120 0.0160 0.0199 0.0239 0.0279 0.0319 0.0359 0.0398 0.0438 0.0478 A 0.3186 0.3212 0.3238 0.3264 0.3289 0.3315 0.3340 0.3365 0.3389 Z 0.3413 0.3438 0.3461 0.3485 0.3508 0.3531 0.3554 0.3577 0.3599 0.3621 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2 0.21 0.22 0.23 0.24 0.25 1.12 1.13 1.14 1.15 1.16 1.17 A z 0.0517 0.0557 0.26 0.27 0.28 0.29 0.0596 0.0636 0.0675 0.3 0.0714 0.31 0.0753 0.32 0.0793 0.33 0.0832 0.34 0.0871 0.35 0.0910 0.0948 0.0987 1.18 1.19 1.2 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 A 0.3643 0.3665 0.3686 0.3708 0.3729 0.3749 0.3770 0.3790 0.3810 0.36 0.3830 0.3849 0.3869 0.3888 0.3907 0.3925 0.3944 0.3962 0.3980 0.3997 0.37…arrow_forwardSix standard deviations of a normally distributed process use 85% of the specification band. It is centered at the nominal dimension, located halfway between the upper and lower specification limits. Estimate C, and C₂. Interpret these ratios.arrow_forwardA laboratory temperature standard is used to calibrate an automated temperature measuring system from sensor through conditioning equipment to its final indicated output value. The measuring system sensor is placed in the identical environment as the standard sensor. The indicated output values from the system are compared over a range of temperatures based on many readings at each of six setpoint temperatures. Estimate a value for the systematic standard uncertainty in the offset correction of the temperature measuring system. Setpoint (C) Indicated Mean ("C) Offset ("C) 0.000 20.000 40.000 60.000 80.000 100.000 0.046 20.067 40.072 60.133 80.057 100.116 0.046 0.067 0.072 0.133 0.057 0.116arrow_forward
- Asaparrow_forwardCardiologists use the short-range scaling exponent α1, which measures the randomness of heart rate patterns, as a tool to assess risk of heart attack. The article “Applying Fractal Analysis to Short Sets of Heart Rate Variability Data” compared values of α1 computed from long series of measurements (approximately 40,000 heartbeats) with those estimated from the first 300 beats to determine how well the long-term measurement (y) could be predicted the short-term one (x). Following are the data (obtained by digitizing a graph). Short Long 0.54 0.55 1.02 0.79 1.4 0.81 0.88 0.9 1.68 1.05 1.16 1.05 0.82 1.05 0.93 1.07 1.26 1.1 1.18 1.19 0.81 1.19 0.81 1.2 1.28 1.23 1.18 1.23 0.71 1.24 Note: This problem has a reduced data set for ease of performing the calculations required. This differs from the data set given for this problem in the text. Compute the least-squares line for predicting the long-term measurement from the short-term measurement.…arrow_forwardPressure distribution measurements are made on a two-dimensional wing model placed in a wind tunnel. The difference between the static pressure sockets on the surface and the static pressure of the free stream is measured. 30 data is taken at each measurement point. The average of the values measured from one of the sockets near the trailing edge was calculated as 2.30 Pa, and the standard deviation was calculated as 2.65 Pa. After applying the Chauvenet criterion to these measurement values, it was decided to eliminate 3 measurements and the new mean value was found to be 2.18 Pa and the standard deviation was 2.42. It was verified that the unexcluded data fit the normal distribution curve. Data above how many Pa and below how many Pa were eliminated? Estimate how many data have negative value (?<0) after elimination.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
What is Metrology in Mechanical Engineering? | Terminologies & Measurement; Author: GaugeHow;https://www.youtube.com/watch?v=_KhMhFRehy8;License: Standard YouTube License, CC-BY