Textbook Question
Chapter 4, Problem 10R
What are the colors of the conductors in nonmetallic-sheathed cable for
- a. 2-wire cable? _______________, _______________
- b. 3-wire cable? _______________, _______________, _______________
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
H2. A/An _______ is an insulating tube or sleeve that protects an electrical conductor where it passesthrough a hole.A. expansion fittingB. couplingC. gland nutD. bushing
H3. Conductors that are larger than AWG size 8 will come only as a/an _______ conductor.A. aluminumEnd of examB. coveredC. solidD. stranded
Grounding lighting fixtures. Threre are specific requirements for grounding lighting fixtures. How must they be grounded and with what size conductors?
Connectors marked ____ are suitable for use with aluminum, copper, or copper-clad conductors?
1. CO-ALR only
2. AL/CU only
3. UL 9
4. CO-ALR and AL/CU
What is the correct answer? Why?
Chapter 4 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 5. Which of the following descriptions of a ground ring is correct?A. A ground ring is a circular formation that's made up of six or more grounding electrodes.B. A ground ring is a coiled conductor that's buried underneath a utility pole.C. A ground ring is a device that's used to clamp a conductor to a water pipe.D. A ground ring is a bare copper conductor that will encircle an entire structure underground.arrow_forwardThe ohms per 1000 feet measurements for conductors can be found in _____. Select one: a. article 100 definitions b. 310.15(B)(16) c. annex C d. chapter 9 Table 8arrow_forwardThe minimum point of attachment of the service-drop conductors to a building must in no case be less than above finished grade. A. 8 ft B. 10 ft C. 12 ft D. 15 ftarrow_forward
- what is the minimum size single conductor of copper jacketed mineral insulated cable that can for a consumer's service?arrow_forwardWhich of the following is an installation requirement for the grounding electrode conductor in acommunications system?A. It must be run as straight as practicable.B. It must be, at minimum, 4 AWG.C. It must be solid or stranded aluminum.D. It must be isolated and covered.arrow_forwardClassify and give a detailed discussion of each category of power conductor and cables.arrow_forward
- b. 63 rule where two different temperatures are encountered for the same conductors 38. An exception to the permits the application of the higher ampacity (lower temperature) if the length of the conductors that enter a higher temperature is not more than 10 ft (3.0 m) or not more than 10% of the total circuit length. C. ampacity rating d. flux rating a. circuit derating b. ampacity derating lood isarrow_forward4. What is the effect of laid cables in proximity to each other?arrow_forwardWhen connecting a multiwire (3-wire) circuit to a single phase panel, one ungrounded conductor must be connected to the ____ phase and the other ungrounded conductor must be connected to the ____ phase. Select one: a. A, A b. B, B c. A, B d. doesn’t matterarrow_forward
- A cable one mile long and 0.50 inch in diameter is composed of a steel core 0.25 inch in diameterand the outside shell is aluminium . The resistance of the cable is _____ ifρ1andρ2are 57.4 and17.5 ohms–cmil / ft. ,respectivelyarrow_forward***** ************** Q4/I. Two conductors of a d.c. distributor cable AB 1000 m long have a total resistance of 0-1 Q.. The cable is uniformly loaded at 0:5 A per metre length and has concentrated loads as shown below. Calculate (i) Currents supplied from ends A and B. (ii) The point of minimum potential (iii) The value of minimum potential 240V 240V 200m C D 300m E 200m F 100m B 120A 60A 100A 40Aarrow_forwardWiring methods permitted for service conductors include. A. Rigid metal conduit B. Electrical metallic tubing C. Rigid nonmetallic conduit D. all of thesearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License