EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Textbook Question
thumb_up100%
Chapter 4, Problem 46R
Are set screw–type connectors permitted to be used with armored cable that has an aluminum armor? _____
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
All cut ends of conduits shall be reamed or otherwise finished to remove rough edges. Where conduit is threaded in the field, a standard cutting die with a ____ -in. taper per ft (1 in 16) shall be used.
Select one:
A. 3/8
B. 1/2
C. 1
D. 3/4
H1. If you need to make a straight connection to splice two conductors (both size 4 AWG) together, whichof the following connection methods should you use?A. A pressure connectorB. A barrel crimpC. A butt crimpD. A wire nut
H2. A/An _______ is an insulating tube or sleeve that protects an electrical conductor where it passesthrough a hole.A. expansion fittingB. couplingC. gland nutD. bushing
H3. Conductors that are larger than AWG size 8 will come only as a/an _______ conductor.A. aluminumEnd of examB. coveredC. solidD. stranded
_______ connectors are intended for use only with cable employing corrugated copper tube.
A. Aluminum C. Bronz
B. Metal-clad D. Steel
Chapter 4 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
Assume a telephone signal travels through a cable at two-thirds the speed of light. How long does it take the s...
Electric Circuits (10th Edition)
Analog Voltmeter Design Figure P2-98(a) shows a voltmeter circuit consisting of a D'Arsonval meter, two series ...
ANALYSIS+DESIGN OF LINEAR CIRCUITS(LL)
Find I0 and I1 in the circuit in Fig.P2.12.
Basic Engineering Circuit Analysis
When travelers from the USA and Canada visit Europe, they encounter a different power distribution system. Wall...
Electric machinery fundamentals
The voltage source of the circuit shown in Fig. P1.29 is given by s(t)=25cos(4104t45)(V). Obtain an expression ...
Fundamentals of Applied Electromagnetics (7th Edition)
For the “tank” circuit in Fig. 14.79, find the resonant frequency.
Figure 14.79
For Probs. 14.39, 14.71, and 1...
Fundamentals of Electric Circuits
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- List down the different types of Cables.arrow_forwardType MC cable is manufactured in three broad types: interlocked metal tape, smooth tube, and ______________. I answered corrugated metallic sheath and I got an ex. what would be the answer then?arrow_forwardNEC identifies ____ types of rigid PVC conduit. Select one: A. FIVE B. TEN C. THREE D. TWOarrow_forward
- a.2. Which of the following statements about grounding electrode conductors is true?A. They restrict the ground connection.B. They eliminate potential differences between conductive objects and the Earth electrode.C. They facilitate operation of overcurrent protective devices.D. They perform bonding between the Earth and grounded conductors.a.3. Main bonding jumpers are required to be made of _______ or other corrosion-resistant material.A. brassB. aluminumC. copperD. copper-clad aluminumarrow_forwardA cable wire maybe coaxial or twisted. Coaxial costs 25 centavos per meter while twisted wire costs only 18 centavos. The soldering cost for coaxial wire is P1.30 per connection, for twisted wire P1.70. What length of cable run will make the cost of installing coaxial equal to that of the twisted wire. Assume that the number of soldered connection is 350. ANSWER_____________marrow_forwardWhat is grading of cables.Explain?arrow_forward
- Airframe Electrical What is the purpose of the inspection hole on a connector contact?arrow_forward7. An attachment plug establishes connection between ____. Select one: A. CONDUCTORS OF THE ATTACHED FLEXIBLE CORD AND A SUITABLE GROUND B. JUNCTION BOX AND A SUITABLE GROUND C. JUNCTION BOX AND THE ATTACHED FLEXIBLE CORD D. CONDUCTORS OF THE ATTACHED FLEXIBLE CORD AND THE CONDUCTORS PERMANENTLY CONNECTED TO THE RECEPTACLEarrow_forward3.a. When a device is removed from an outlet box, the_______ wire must be connected in such a way that maintains continuity. A. neutral B. grounding C. hot D. grounded neutral 3. To correctly saw a lath and plaster wall, point the teeth of the saw A. away from you and cut on the pushing stroke. B. away from you and cut on the pulling stroke. C. toward you and cut on the pushing stroke. D. toward you and cut on the pulling stroke.arrow_forward
- L1. Boxes are classified by type, construction, andA. installation location.B. luminaire support capability.C. number of knockouts.D. power rating L2. Which of the following devices must be placed at each end of an armored cable to prevent damage tothe conductors?A. An insulating sliderB. An insertion couplingC. An antishort bushingD. A metal loop fitting L3. Which of the following is the maximum cross-sectional conductor fill area for underfloor raceways?A. 50%B. 60%C. 40%D. 30%arrow_forwardWhich of the following products are not suitable for bonding on the supply side of the service disconnecting means? a) Threaded hubs b) Bonding bushings with jumpers c) Standard locknuts d) Threadless connectors made up tightarrow_forward15. A key provision found in most of the cable articles states that the cable must not be installed where subject to ____. Select one: A. WEATHER B. PHYSICAL DAMAGE C. ELECTRICAL INTERFERENCE D. TRAFFICarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License