When connecting a multiwire (3-wire) circuit to a single phase panel, one ungrounded conductor must be connected to the ____ phase and the other ungrounded conductor must be connected to the ____ phase. Select one: a. A, A b. B, B c. A, B d. doesn’t matter
Q: 23. A grounding conductor helps prevent a shock hazard in the event that an ungrounded, or hot,…
A: The explanation is as follows.
Q: 12. Which of the following statements about ground faults is true? A. They can happen if a…
A: Given Which of the following statements about ground faults is true? Mark the correct answer
Q: The grounded circuit (system) conductor is generally not permitted to be used to ground equipment on…
A: Given, The grounded circuit (system) conductor is generally not permitted to be used to ground…
Q: Expansion fittings and telescoping sections of metal raceways shall be made electrically continuous…
A: In Bonding loosely jointed metal raceways, grounding electeode and grounded current carrying…
Q: 4. What can installation records be used to determine while servicing equipment? A. Broken…
A: Installation record refers to an information of equipment ratings, measurement, etc. which is…
Q: For installing directly in a concrete slab, (armored cable), (non metallic-sheated cable), (rigid…
A: For installing directly in a concrete slab Rigid metal conduit (RMC) can be used. A rigid metal…
Q: Q.4. Mention the specifications of EIA/TIA recognized cables and its standard number for each type…
A: With industry input, the TIA/EIA cable standards have been developed by the Telecommunications…
Q: A single branch circuit consists of one ungrounded conductor, one neutral conductor, and one…
A: The explanation is as follows.
Q: may the uninsulated conductor be used for purposes other than grounding?
A: The combination of two or more insulated conductors and ground wire is non-metallic sheathed cable.…
Q: Service-lateral conductors are required to be insulated except for the grounded neutral conductor…
A: According to NEC 230.30 (A), underground service conductors are insulated for the applied voltage.
Q: The minimum size raceway for the following branch circuit conductors is: Twelve, 6 AWG conductors…
A: The transmission of power from one place to another is very necessary, usually, the voltage level of…
Q: Define cable rating in a built environment
A: Cable selection and application : It is essential to know cable construction, characteristics,…
Q: 8- Generally as of the operating voltage which of the following options are the correct words that…
A:
Q: 9. Which type of cable would you use to connect multiple buildings in an industrial facility? A.…
A: Four options are given. We need to choose the correct option. It is asked that which type of cable…
Q: If overcurrent protection is not provided at the source of a separately derived system, the…
A: All ordinarily conductive non-current-carrying metal parts and other conductive materials are…
Q: 5. How many system bonding jumpers normally are there for a separately derived system that's…
A: We are authorized to answer only 1 question at a time since you have not mentioned which question…
Q: 2.a. What's defined as an assembly consisting of a service raceway, guy wires or braces, service…
A: 2.a. Drip loops are used for preventing rainwater and moisture. Thus this is not a suitable…
Q: Where nonmetallic-sheathed cable is run at angles with joists in unfinished basements, it shall be…
A: According to article 334 nonmetallic -sheathed cable . Where nonmetallic-sheathed cable is run at…
Q: n an ungrounded electrical systems with conductors installed in grounded metal raceways and…
A: In an ungrounded electrical system, there is no direct connection with the grounding electrode.…
Q: A conductor with continuous white or gray covering shall be used only for the grounded circuit…
A: According to article NEC 200.6, the facts about the identification of the Grounded conductors are…
Q: How far can a 230V, 50A, three-phase load be located from a panelboard if it's fed with 3 AWG…
A: The Length of the load from the panel board is calculated as shown below
Q: installing
A: From NEC 517-160A5 color code for isolated power conductor.orange with stripe→conductor 1Brown with…
Q: The Voltage Regulation of a Transmission Line should be _____? A. very high percentage. B. more than…
A: C. Zero or nil Option C is correct.
Q: In an overhead system, the basis of comparison is the maximum voltage between conductor and ground.…
A: An overhead power line is a structure that transmits electrical energy across long distances in…
Q: How is the equipment grounding conductor sized?
A: The size of the equipment grounding conductor is determined using the data provided in the national…
Q: What type of electrical conductor is used for underground applications?
A: Type SE or USE cables are used for underground application. This contain two or more conductors, is…
Q: Determine the Primary Conductor Size (include the AWG size number), Secondary Conductor Size…
A: P= 90 KVA Three phase transformer 400/230 V
Q: 19.a. Which term relates to the conductors connected to the output side of a separately derived…
A: A power station is to provide electricity to a huge number of people. Different customer’s power…
Q: In an ungrounded electrical systems with conductors installed in grounded metal raceways and…
A: In an ungrounded system, the system has no direct connection with the grounding electrode. When the…
Q: Determine the minimum number of cubic inches required for two 10 AWG conductors passing through a…
A: AWG or American Wire Gauge is the US standard measure for the diameter of electrical conductors. The…
Q: A set of conductors is used to supply residential unit with a total load current of 60 A at a…
A:
Q: 14. If the total circular mil area of the largest ungrounded service-entrance conductor for a…
A: Explanation: The equivalent area of four ungrounded paralleled 500 kcmil conductors is 2000 kcmil.…
Q: When installing a surge arrester at the service of less than 1000 volts, the grounding conductor…
A: Equipment Grounding Conductor (EGC) – A conductive path that 's a component of a decent ground-fault…
Q: 3. How is the insulation arrangement done for different parts in switchgear?
A: Different types of insulation are used in the constructions of switchgear.
Q: 7. The size of the supply-side bonding jumpers for each of the individual raceways in the parallel…
A: NEC: NEC stands for National Electric Code. It is a regulatory body that set standard for safety…
Q: What is the box fill volume allowance for each conductor originating outside and terminating inside…
A: We need to answer what is the box fill volume allowance for each conductor originating outside and…
Q: separable
A: Given that Which of the following conductors in a typical separable connection plug and receptacle…
Q: What is grading of cables, explain.
A: Grading is defined as the process of equalizing the stress in the dielectric of the cable.…
Q: what is the voltage between neutral and protective earth conductor in the TN-S earthing schemes…
A: In TN-S earthing scheme, T stands for solid earthing, N denotes the presence of the conductor having…
Q: Which of the following criteria is correct for the electrical design of the overhead line? O Tensile…
A: Need to find the criteria for Electrical design of overhead line
Q: What is the largest solid (not stranded) conductor approved for installation in raceways?
A: Solid conductor are made with a single conductive material while stranded conductor are made with…
Q: A two conductor street main AB, 500 meters in length is fed from both end at 250 volts. Load of 50A,…
A: The solution can be achieved as follows.
Q: is the required size of THHN copper conductors for a feeder serving two 208Y/120V, four-wire,…
A:
Q: How many 14 AWG THHN conductors, including an equipment grounding conductor, can be installed in a…
A: Here we have to refer standard tables, When determining the maximum number of conductors permitted…
Q: The copper line with a total length of 20 meters operates in the 220 volt city network. If three…
A:
Q: Why do multiple conductors in dc, 1-phase, and 3-phase power cables not disturb the magnetic compass…
A: Multiple conductors in DC, 1- phase, or 3 phase power cables do not disturb the magnetic compass…
Q: On a 120/240 V, single-phase, three-wire system, identify the following: a. Voltage between one…
A:
Q: What is the rated amps city per phase for six No. 3 THHN copper current-carrying conductors with two…
A: Conductor amps city -- The amps city of six No. 3 THHN conductor installed in the same raceway must…
Q: Draw the block diagram of staircase ramp type digita oitmeter and explain the same.
A: consider the given question;
When connecting a multiwire (3-wire) circuit to a single phase panel, one ungrounded conductor must be connected to the ____ phase and the other ungrounded conductor must be connected to the ____ phase.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- 3. The three bus-bar conductors in an outdoor sub-station are supplied by units ofpost insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station. [38-8 kV]The three bus-bar conductors in an outdoor sub-station are supplied by units of post insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station.h.1. In an alternating-current system, the maximum size for a copper grounding electrode conductor isA. 250 kcmil.B. 3/0.C. 500 kcmil.D. 4/0. h.2. The figure shows a fault condition in an ungrounded electrical system. Which of the following will occurbecause of the fault in this system?A. Only the overcurrent protector at Point A will trip open.B. The ground fault will heavily damage the service.C. Nothing will happen until a second ground fault occurs.D. The overcurrent protection will trip, shutting off all the line side power.
- a) Differentiate between Single Phase Three Wire and Two Phase Three Wire.Most residential general lighting circuits are wired with 14-AWG copper conductors and are protected by 15-amp circuit breakers. However, there are many electricians who install 12-AWG copper conductors and protect them with 20-amp circuit breakers. How will you know which conductor size and which circuit breaker size will be used for the general lighting branch circuits in the house you are wiring?H2. A/An _______ is an insulating tube or sleeve that protects an electrical conductor where it passesthrough a hole.A. expansion fittingB. couplingC. gland nutD. bushing H3. Conductors that are larger than AWG size 8 will come only as a/an _______ conductor.A. aluminumEnd of examB. coveredC. solidD. stranded
- Count the neutral conductor of a 4-wire, 3-phase, wye-connected circuit when the major portion of the load is electric discharge lighting (fluorescent, mercury vapor, high-pressure sodium, etc.), data processing, and other loads where the neutral conductor carries a. grounding b. traveler C. d. current. third harmonic unbalanced conductors to overheat but often overlooked is the possibility of8.a. A _______ conductor does not carry current during normal operation.A. neutralB. groundingC. phaseD. grounded8.b. "The complete path of an electric current" describes an electric(al)A. fault.B. circuit.C. source.D. component.8. Parallel conductors must be installed in sizes no smaller thanA. 1/0.B. 2/0.C. 750 kcmil.D. 4/0.
- A? Conductor is defined in NEC 240.2 as a conductor, other than a service conductor, having overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are not taps. A. Faulted b. Tap c. Magnetic d. Copper-like7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.12 - Due to the effect of the resistance of the cable connected to RTD, two-wire cables up to ……. meters and three-wire cables up to ……... meters are used in standard designs. A) 10-150B) 40-500C) 50-195D) 30-230E) 200-1000