Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
thumb_up100%
Chapter 3, Problem 3.2.3P
To determine
(a)
The service load using Load and Resistance Factor Design (LRFD).
To determine
(b)
The service load using Allowable Strength Design (ASD).
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A C8 × 11.5 is connected to a gusset plate with 7⁄8-inch-diameter bolts as shown in the Figure . The steel is A572 Grade 50. If the member is subjected to dead load and live load only, what is the total service load capacity if the live-to-dead load ratio is 3? Assume that Ae = 0.85An.a. Use LRFD.b. Use ASD.
A C8 × 11.5 is connected to a gusset plale with 22 mm diameter bolts as shown. The steel is A572 Grade 50. If the
member is subjected to dead load and live load only, what is the total scrvice load capacity if the live-to-dead load
ratio is 3? Assume that Ae = 0.85Ap.
a. Use LRFD.
b. Use ASD.
Properties of A572 Grade 50:
Fy = 345 MPa
C8 × 11.5
Fu = 448 MPa
Properties of C8 x 11.5:
Ag = 2,181 mm?
br = 57.4 mm
d= 203.2 mm
Lw = 5.6 mm
lf = 9.9 mm
Two plates each with thickness t = 16 mm are bolted together with 6 – 22 mm diameter bolts forming
a lap connection. Bolt spacing are as follows: S1 = 40 mm, S2 = 80 mm, S3 = 100 mm. Bolt hole
diameter = 25 mm. Using A36 steel having Fy = 248 MPa and Fu = 400 MPa.
P P
S
- P
S2
S2
DETERMINE:
1. Determine the allowable load Pa based on bearing at bolt holes. (ASD)
2. Determine the ultimate load Pu based on block shear.
Chapter 3 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 3 - Prob. 3.2.1PCh. 3 - Prob. 3.2.2PCh. 3 - Prob. 3.2.3PCh. 3 - Prob. 3.2.4PCh. 3 - Prob. 3.2.5PCh. 3 - Prob. 3.2.6PCh. 3 - Prob. 3.3.1PCh. 3 - Prob. 3.3.2PCh. 3 - Prob. 3.3.3PCh. 3 - Prob. 3.3.4P
Ch. 3 - Prob. 3.3.5PCh. 3 - Prob. 3.3.6PCh. 3 - Prob. 3.3.7PCh. 3 - Prob. 3.3.8PCh. 3 - Prob. 3.4.1PCh. 3 - Prob. 3.4.2PCh. 3 - Prob. 3.4.3PCh. 3 - Prob. 3.4.4PCh. 3 - Prob. 3.4.5PCh. 3 - Prob. 3.4.6PCh. 3 - Prob. 3.5.1PCh. 3 - Prob. 3.5.2PCh. 3 - Prob. 3.5.3PCh. 3 - Prob. 3.5.4PCh. 3 - Prob. 3.6.1PCh. 3 - Prob. 3.6.2PCh. 3 - Prob. 3.6.3PCh. 3 - Select an American Standard Channel shape for the...Ch. 3 - Prob. 3.6.5PCh. 3 - Use load and resistance factor design and select a...Ch. 3 - Select a threaded rod to resist a service dead...Ch. 3 - Prob. 3.7.2PCh. 3 - Prob. 3.7.3PCh. 3 - Prob. 3.7.4PCh. 3 - Prob. 3.7.5PCh. 3 - Prob. 3.7.6PCh. 3 - Prob. 3.8.1PCh. 3 - Prob. 3.8.2PCh. 3 - Prob. 3.8.3PCh. 3 - Prob. 3.8.4PCh. 3 - Prob. 3.8.5P
Knowledge Booster
Similar questions
- A C8 x 11.5 is connected to a gusset plate with 7/8-inch-diameter bolts as shown in Figure P3.2-3. The steel is A572 Grade 50. If the member is subjected to dead load and live load only, what is the total service load capacity if the live-to-dead load ratio is 3? Assume that A = 0.85A,,. C8 × 11.5arrow_forwardAn L 5 x 5 x tension member of A588 steel is connected to a gusset plate with six -inch- diameter bolts as shown in Figure P3.3-4. If the member is subject to dead load only, what is the maximum total service load that can be applied if the ratio of live load to dead load is 2.0? Use the alternative value of U from AISC Table D3.1 (Consider yielding & rupture limit states only.) a. Use LRFD b. Use ASD L5 x 5 x '½ 1'/2" 5 spaces @ 3" - 15" 12" FIGURE P3.3-4 na.coarrow_forwardTopic:Bolted Steel Connection - Civil Engineering *Use latest NSCP/NSCP 2015 formula to solve this problem *Please use hand written to solve this problem The bracket shown in the figure is supported by four 22 mm diameter bolts in single shear. The bracket is subject to an eccentric load of 150 kN. Use LRFD. Use A36 steel. Questions a) Determine the critical force on the most stressed bolt. b) Determine the nominal shear stress of the most stressed bolt.arrow_forward
- A 15" x 3/8" bar of A572 Gr. 50 steel is used as a tension member. It is connected to a gusset plate with 7/8-in diameter bolts as shown in the figure. Use s = 2.0 and g = 3.0.a) Determine the design tensile strength of the section based on yielding of the gross area.b) Determine the critical net area of the connection shown.arrow_forwardConsidering the following steel connection. The plates in Pink are 9mm steel plates. The middle plate (Yellow) is 18mm thick. The width of the plate is 100mm. The maximum allowable tension stresses on any of the plates is 100Mpa in Gross Area Yielding and 150 Mpa for Net Area or Tension Rupture. The bolts used are 8mm in diameter, the holes are 10mm in diameter, no need to add 1.6mm. The bolts allow a maximum of 280 Mpa of shear. Determine the maximum allowable "P" of the connection in kN.arrow_forwardA C8 x 11.5 is connected to a gusset plate with 7/8 inch diameter bolts as shown in Figure P3.2-3. The steel is A572 Grade 50. If the member is subjected to a dead load and live load only, what is the total service load capacity if the live to dead load ratio is 3? Assume that Ae=0.85An. Use LRFD and ASD.arrow_forward
- A structural tee bracket is attached to a column flange with six bolts as shown in Figure . All structural steel is A992. Check this connection for compliance with the AISC Specification. Assume that the bearing strength is controlled by the bearing deformation strength of 2.4dtFu. a. Use LRFD. b. Use ASD.arrow_forward1.A tension member is 25 mm thick plate as shown. The bolts are 20 mm. diameter high-strength bolts. The steel is A36. Compute the following: 130 mm 25 mm 0 0 a) The design strength for LFRD. b) The allowable strength for ASD. 25 mm CIVIL ENGINEERING STEEL DESIGNarrow_forwardA PL 38 x 6 tension member is welded to a gusset plate as shown in figure. The steel is A36. PL ½ x 6 The design strength based on yielding is nearest to: The design strength based on rupture is nearest to: The design strength for LRFD is nearest to: The allowable strength based on yielding is nearest to: The allowable strenath based on rupture is nearest to: The allowable strength for ASD.arrow_forward
- 4. Calculate the design strength (ocPn) of W24X76 with length of 12 ft. and pinned ends. A572 Grade50 steel is used. E=29x103 ksi. Show your work in detail. ASTM Classification A36 A572 Grade 50 A992 Grade 50 A500 Grade B (HSS rect, sq) A500 Grade B (HSS round) A53 Grade B Yield Strength F, (ksi) 36 50 50 46 42 35 Ultimate Strength F (ksi) 58 65 65 58 58 60arrow_forwardA plate with width of 420 mm and thickness of 13 mm is to be connected to a plate of the same width and thickness by 30 mm diameter bolts, as shown in the Figure 1. The holes are 3mm larger than the bolt diameter. The plate is A36 steel with yield strength Fy = 248MPa. Assume allowable tensile stress on net area is 0.60Fy. It is required to determine the value of b such that the net width along bolts 1-2-3-4 is equl to the net width along bolts 1-2-4. W = 420 mm t = 13 mm a = 64 mm c = 104 mm d = 195 mm Bolt Diameter = 30 mm Holes Diameter = 30 mm + 3 = 33 mm ?? = 248 MPa Allowable Tensile Stress on ?? = 0.60Fy a. Calculate the vaue of b in millimeters. b. Calculate the value of the net area for tension in plates in square millimeters. c. Calculate the value of P so that the allowable tensile stress on net area will not be exceeded.arrow_forward2. For the figure shown, calculate the net area of the 10 x 200 mm plate. The plate is connected at its end with two lines of 20 mm bolts. Using LRFD, determine the load P that the plates can carry against tensile yielding in the gross section and the tensile rupture in the net section. Use A-36 steel. PL 5x200mm PL 5x200mm Pu PL 10x200mm Puarrow_forward
arrow_back_ios