Chapter 28, Problem 28.4QAP
How can the selectivity factor be manipulated in (a) GC and (b) LC?
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
TLC was used to compare the solubility of two compounds A and B in a solvent system (acetic acid, methanol, H2O). The distances that solvent has moved in the silica gel TLC was 12 cm. and for the compounds were 2 and 8 cm respectively. (a) Calculate the Rf values and which compound is more soluble and which one is more polar. (b) What are the factors affecting the Rf value
Different from GCMS, why is an interface needed when coupling HPLC with MS?
(i) Calculate the capacity factors (k') for both compounds A and B and the selectivity factor (a) between them, commenting on the values. (ii) Calculate the resolution between A and B and comment on it. (iii) Using the peak for A, calculate the number of theoretical plates for the GC column and comment on the quality of the column.
Chapter 28 Solutions
Principles of Instrumental Analysis
Ch. 28 - Prob. 28.1QAPCh. 28 - Prob. 28.2QAPCh. 28 - Prob. 28.3QAPCh. 28 - How can the selectivity factor be manipulated in...Ch. 28 - Prob. 28.5QAPCh. 28 - Prob. 28.6QAPCh. 28 - Prob. 28.7QAPCh. 28 - Prob. 28.8QAPCh. 28 - Prob. 28.9QAPCh. 28 - Prob. 28.10QAP
Ch. 28 - Prob. 28.11QAPCh. 28 - Prob. 28.12QAPCh. 28 - Prob. 28.13QAPCh. 28 - Prob. 28.14QAPCh. 28 - Prob. 28.15QAPCh. 28 - Prob. 28.16QAPCh. 28 - Mass spectrometry is an extremely versatile...Ch. 28 - Prob. 28.18QAPCh. 28 - Prob. 28.19QAPCh. 28 - Two components in an HPLC separation have...Ch. 28 - Prob. 28.21QAPCh. 28 - Prob. 28.22QAPCh. 28 - Prob. 28.23QAP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- 1. From spinach, the chromatographic analysis will yield two major substances: (a) B-carotene (C40H56), which will separate from the spinach mixture to form a yellow band, and (b) chlorophyll A (CSSH72MGN4OS), which will separate from the mixture to form a green band. i. Describe the characteristics and draw structures of these molecules. ii. From the spectrophotometric analysis, what wavelength (Amax) would you expect ß-carotene (C40H56) to absorb? What wavelength would chlorophyll A (CssH72MgN4O5) absorb?arrow_forwardwhat chromatography seperation how is tlc part of itarrow_forwardExplain why TLC cannot be used for some volatile low molecular weight substances such as toluene.arrow_forward
- 6b. why doce CE have better performance than LC in separationarrow_forwardA spectrophotometric method for the quantitative determination of the concentration ofPb2+ in blood yields an Ssamp of 0.133 for a 1 mL sample of blood that has been diluted to 6 mL. A second sample is spiked with 1 µL of a 1467 ppb Pb2+ standard and diluted to 6 mL, yielding an Sspike of 0.491. Determine the concentration of Pb2+ in the original sample of blood.arrow_forwardCan paper chromatography be used to separate and identify very volatile substances? Why? Please explain comprehensively.arrow_forward
- What structural features of Hydroxypropyl Acrylate (HPA) allow it to be detected by HPLC?arrow_forwardGiven C6H12O2 chemical formula. chemical shift , intergration, multiplicity and interpretation needed.arrow_forwardPlease help with the Chemical shift Splitting pattern Integration HNMRarrow_forward
- state the three different modes of GC/MS, and explain more for each.arrow_forward4) 1.580 g soil sample was analyzed for its copper content. The soil sample was completely digested with HNO3-H2O2 mixture and diluted to 50.0 mL with distilled water. 2.0 mL of this solution was taken into a volumetric flask and diluted to 10.0 mL with distilled water. It was analyzed by FAAS system and its average absorbance was calculated as 0.2564. Calibration plot for copper is shown below. Absorbance 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0 10 y = 0,0291x-0,0082 R² = 0,9993 15 Copper, mg/L 20 Calculate the percentage of copper in the soil sample as ppm. 25arrow_forwardMass spectrometry is an extremely versatile detection system for GC. However, interfacing an HPLC system to a mass spectrometer is a much more difficult task. Describe the major reasons why it is more difficult to combine HPLC with mass spectrometry than it is to combine GC with mass spectrometry.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningEBK A SMALL SCALE APPROACH TO ORGANIC LChemistryISBN:9781305446021Author:LampmanPublisher:CENGAGE LEARNING - CONSIGNMENT
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:9781305446021
Author:Lampman
Publisher:CENGAGE LEARNING - CONSIGNMENT
Mass Spectrometry; Author: Professor Dave Explains;https://www.youtube.com/watch?v=hSirWciIvSg;License: Standard YouTube License, CC-BY