The working current has a power of 100 kW and a power factor of 0.50. After a capacitor of 75 KVAR is installed, what does the
power factor become?
A 0.84
B 0.71
C 0.63
D 0.78
E 0.92
A 3 kVA motor operates from a 240 V
supply at 50 Hz and has a power
factor of 0.6. Determine the active
power
Select one:
1800 W
Non of the Answers
1900 W
2000 W
al
Three coils each having resistance of 29 N are connected in star across 422 V, 50 Hz supply. Then the total
power consumed is
O 211.77 W
O 3545.51 W
O 730.95 W
O 6140.83 W
Chapter 21 Solutions
Electrical Transformers and Rotating Machines
Knowledge Booster
Similar questions
- Two transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forwardA 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forward
- How does the National Electrical Code specify that the high leg of a four-wire delta connection be marked?arrow_forwardThe following data were obtained on a 50 kVA 2400/120 V transformer: Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.The following data were obtained on a 50 kVA 2400/120 V transformer : Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.arrow_forwardIn a given DC motor, the output power is 20 HP, and the copper losses are 1.1 KW. If the motor is operating at 87 % efficiency, find the converted power and the rotational losses. Select one: a. Pconv = 16.05 KW and Prot = 1.13 KW b. Pconv = 17.15 KW and Prot = 3.11 KW c. Pconv = 14.92 KW and Prot = 1.35 KW d. Nonearrow_forward
- Question 4 A 228 V/ 111 V single-phase transformer has a core loss of 110 W and the no-load current is 0.7 A. The no load power factor is Not yet answered Marked out of O 0.99 1.00 O 1.42 P Flag question O 0.48 O 0.69 Question 5 A 2 kV / 229 V transformer has the secondary turns of 47. The number of Primary turns of a transformer is given by, Not yet answered 63.83 Marked out of 410.48 1.00 O 615.72 P Flag question O 5381.50 Question 6 For the given power transfer, a delta system is associated with larger line currents and a star system is associated with a larger line voltage. Not yet answered Select one: Marked out of O True 1.00 P Flag question O Falsearrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forwardFind the value of the currents I1 and 12. 100 ohm 5V 5V 100 ohm 12 O a. 1=-0.3A, 12=-0.1A O b. 11=0.3A, 12=0.1A Oc. 11=0.05A, 12=0.1A O d. 11=0.1A, 12=0.2Aarrow_forward
- A balanced star-connected load of (8 + j6) Q per phase is connected to a Balanced 3- phase 400-V supply. Find the line current, power factor, powerarrow_forwardAn alternator with a line voltage of 2400 V supplies a delta-connected load. The line current supplied to the load is 40 A. Assuming the load is a balanced three-phase load, what is the impedance of each phase?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning