Textbook Question
Chapter 7, Problem 9RQ
An alternator with a line voltage of 2400 V supplies a delta-connected load. The line current supplied to the load is 40 A. Assuming the load is a balanced three-phase load, what is the impedance of each phase?
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A balanced star-connected load of (8 + j6) Q per phase is connected to a Balanced 3- phase 400-V supply. Find the line current, power factor, power
1. Two compound generators are operated in parallel. If generator A has a
series-field resistance of 0.0015 ohm and is adjusted to take 20 percent of the
line load while generator B with a series field resistance of 0.001 ohm takes
the remainder of the load.
Determine the current flow in the two series fields and the equalizer when the
load is 250 kw at 230 volts.
4. A circuit contains a 20-2 resistor and
an inductor with an inductance of
0.093 H. If the circuit has a frequency
of 60 Hz, what is the total impedance
of the circuit?
5. An R-L series circuit has a power
factor of 86%. By how many degrees
are the voltage and current out of
phase with each other?
6. An R-L series circuit has an apparent
power of 230 VA and a true power of
180 W. What is the reactive power?
7. The resistor in an R-L series circuit
has a voltage drop of 53 V, and the
inductor has a voltage drop of 28 V.
What is the applied voltage of the
circuit?
Chapter 7 Solutions
Electrical Transformers and Rotating Machines
Ch. 7 - Prob. 1RQCh. 7 - Prob. 2RQCh. 7 - A wye-connected load has a voltage of 480 V...Ch. 7 - A wye-connected load has a phase current of 25 A....Ch. 7 - Prob. 5RQCh. 7 - A delta connection has 30 A of current flowing...Ch. 7 - A three-phase load has a phase voltage of 240 V...Ch. 7 - If the load in question 7 is connected in a wye,...Ch. 7 - An alternator with a line voltage of 2400 V...Ch. 7 - Prob. 10RQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A load impedance of 52 Ω is connected to the secondary winding of the transformer in question 3. How much current will flow in the secondary?arrow_forwardIf the secondary of the transformer in question 5 supplies a current of 9.6 amperes to a load, what is the primary current? (Disregard excitation current.)arrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forward
- The following data were obtained on a 50 kVA 2400/120 V transformer: Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.The following data were obtained on a 50 kVA 2400/120 V transformer : Open circuit test, instruments on low voltage side: Waltmeter reading = 396 Watts Ammeter reading = 9.65 amperes Voltmeter reading = 120 Volts Short circuit test, instruments on high voltage side: Waltmeter reading = 810 Watts Ammeter reading = 20.8 amperes Voltmeter reading = 92 Volts Find the efficiency when rated kVA is delivered to a load having a power factor of 0.8 lagging.arrow_forwardA three-phase transformer connection has a delta-connected primary and a wye-connected secondary. The center tap of the wye is used as a neutral conductor. If the line-to-line voltage is 480 volts, what is the voltage between any one phase conductor and the neutral conductor?arrow_forwardAn open-delta three-phase transformer system has one transformer center-tapped to provide a neutral for single-phase voltages. If the voltage from line to center tap is 277 volts, what is the high-leg voltage?arrow_forward
- A 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardWhat is the peak voltage of a 120V RMS AC voltage?arrow_forwardExample 7-3. A 460-V, 25-hp. 60-Hz, four-pole, Y-connected induction motor has the following impedances in ohms per phase referred to the stator circuit: - 0.641n X,-1.106 N R2 - 0.332 N X2 = 0.464 XM - 26.3 N The total rotational losses are 1100 W and are assumed to be constant. The core loss is lumped in with the rotational losses. For a rotor slip of 2.2 percent at the rated voltage and rated frequency, find the motor's (a) Speed (b) Stator current (c) Povwer factor (d) Peony and Pout (e) Tiad and Toad Efficiencyarrow_forward
- Find the currents 11 and 10 in the circuit using current division 2kQ I 6kQ 3kN 12kΩ 9mA 1.arrow_forwardA shunt generator supplies a 26kW load at 235V through cables of resistance, R = 112mQ. If the field winding resistance, Rf =560 and the armature resistance, Ra =47MQ. Determine the following below: The terminal voltage is, The e.m.f. generated in the armature is,arrow_forwardA 10kW, 120V-DC series generator has an armature resistance of 0.1 ohms and a series field resistance of 0.05 ohms. Assuming that it is delivering rated current at rated speed, find the a) armature current and b) induced emf. (Write only the value without the unit) la = Blank 1 A Ea = Blank 2 V (Round-off to 2 decimal places)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage LearningUnderstanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Fluid Mechanics - Viscosity and Shear Strain Rate in 9 Minutes!; Author: Less Boring Lectures;https://www.youtube.com/watch?v=_0aaRDAdPTY;License: Standard youtube license