Programmable Logic Controllers
5th Edition
ISBN: 9780073373843
Author: Frank D. Petruzella
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 14, Problem 3P
How would an on/off controller respond if the deadband were too narrow?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A PWM signal is required for a motor controller. The PWM is generated by a TPM in a KL25Z. The signal for no motion of the motor is a 10 millisecond period with a 50% duty
cycle. Which setup below is NOT a correct setup for a TPM for this starting condition? Ignore the "-1" adjustment for the counts. It is not important in this application.
Clock: 3.2768 MHz
Prescale: 64
Period: 512
Pulse Width: 256
Clock: 4 MHz
Prescale: 4
Period: 10,000
Pulse Width: 5.000
Clock: 8 MHz
Prescale: 2
Period: 20.000
Pulse Width: 10,000
Clock: 24 MHz
Prescale: 16
Modulus: 15.000
Pulse Width: 7,500
Feedback from sensors or switches is the separation of controller and process
true O
False
A home security system has a master switch that is used to enable an alarm, lights, video cameras, and a call to local
police in the event one or more of six sets of sensors detects an intrusion.
In addition there are separate switches to enable and disable the alarm, lights,
and the call to local police. The inputs, outputs, and operation of the enabling logic are specified as follows:
Inputs:
S: signals from six sensor sets (8 =
M: master switch (0 = security system enabled, 1 = security system disabled)
A: alarm switch (0 = alarm disabled, 1 = alarm enabled)
L: light switch (0 = lights disabled, 1 = lights enabled)
P: police switch (0 = police call disabled, 1 = police call enabled)
intrusion detected from the sensors, 1 = no intrusion detected)
Outputs:
A: alarm (e = alarm on, 1 = alarm off)
L: lights (0 - lights on, 1 - lights off)
V: video cameras (0 = video cameras off, 1 = video cameras on)
C: call to police (8 = call off, 1 = call on)
Operation:
If one or more of the sets of…
Chapter 14 Solutions
Programmable Logic Controllers
Ch. 14 - Compare continuous and batch processes.Ch. 14 - Prob. 2RQCh. 14 - State the basic function of each of the following...Ch. 14 - State the purpose of each of the following types...Ch. 14 - Prob. 5RQCh. 14 - Prob. 6RQCh. 14 - Prob. 7RQCh. 14 - Prob. 8RQCh. 14 - Prob. 9RQCh. 14 - Prob. 10RQ
Ch. 14 - Prob. 11RQCh. 14 - What term of a PID control is designed to...Ch. 14 - Prob. 13RQCh. 14 - Prob. 14RQCh. 14 - Prob. 15RQCh. 14 - Prob. 16RQCh. 14 - Prob. 17RQCh. 14 - Prob. 18RQCh. 14 - Prob. 19RQCh. 14 - List four types of communication tasks provided by...Ch. 14 - Prob. 21RQCh. 14 - What are the three general levels of functionality...Ch. 14 - Prob. 23RQCh. 14 - Prob. 24RQCh. 14 - Compare device and process bus networks.Ch. 14 - Prob. 26RQCh. 14 - Prob. 27RQCh. 14 - Prob. 28RQCh. 14 - Prob. 29RQCh. 14 - Summarize the collision detection network access...Ch. 14 - Prob. 31RQCh. 14 - Prob. 32RQCh. 14 - Prob. 33RQCh. 14 - Prob. 34RQCh. 14 - Prob. 35RQCh. 14 - Prob. 36RQCh. 14 - Prob. 37RQCh. 14 - Prob. 38RQCh. 14 - Prob. 39RQCh. 14 - Explain how redundant media works.Ch. 14 - Prob. 41RQCh. 14 - Prob. 42RQCh. 14 - Prob. 43RQCh. 14 - Prob. 44RQCh. 14 - Summarize the two main functions of a SCADA...Ch. 14 - Prob. 46RQCh. 14 - Prob. 1PCh. 14 - Prob. 2PCh. 14 - How would an on/off controller respond if the...Ch. 14 - In a home heating system with on/off control, what...Ch. 14 - a. Calculate the proportional band of a...Ch. 14 - Prob. 6PCh. 14 - Prob. 7PCh. 14 - Prob. 8P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, computer-science and related others by exploring similar questions and additional content below.Similar questions
- If you are given a feedback control system with finite stead-state error, what do you need to do in order to eliminate the error and maintain the transient response performance at the same time? O Add a PD compensator. Decrease the system type. O Decrease the gain. O Add a Pl compensator, Increase the gain. Increase the system type. Question 16 What's the main purpose of a PD controller? Decrease the system type. Increase the system type. Make the system stable. Reduce the steady-state error while maintaining the transient response performance. Improve the transient response performance while maintaining the steady-state error Improve both transient response performance and the steady state errorarrow_forwardDigital control system is a future generation control system. Draw a blockdiagram of a digital controller.arrow_forwardA combinational switching network, has four inputs (a,b,c,d) and the output is the integer of ( half input). Design the network circuit.arrow_forward
- When eight or more bits of information can be sent at once, the electrical connection is said to have a parallel interface.arrow_forwardDEVELOP A PROGRAME / CODE IN ARDUINO SOFTWARE FOR TRAFFIC LIGHT OPERATION USIN ARDUINI UNO CONTROLLER.arrow_forwardHow do different insulation materials in cables affect signal integrity?arrow_forward
- H.W: Write a short report about using internet of things (loT) in speed control of a three- phase induction Motor. POWER TRANSFORMER BRIDGE RECTIFIER WITH FILTER THREE PHASE INVERTER THREE PHASE INDUCTION MOTOR DRIVER TRANSFORMER DRIVER CIRCUIT SPEED FEEDBACK POWER SUPPLY ARDUINO CONTROLLER NODE MCU POWER SUPPLYarrow_forwardFor an ARM micro-controller, the analog input to the ADC is 3.3 volt and the digitization binary output is 12 Bits. For this ADC, what is the input analog resolution and the output resolution of the ADC?arrow_forwardA car manufacturer proposed to implement a simple DCS along a 50 m-long engine production line. The proposed system consists of a 16-bit PLC system, three sensors, and four mechanical actuators. The system components are interconnected using a copper wire network solution. The transmission speed of the network is 40 kbits/s. Two types of network configuration are to be considered, a CAN-based network, and a centralized controller network. A) Draw simple diagrams to show the difference between these two network configurations. B) In CAN, explain why logic '1' is referred to as Recessive logic, and logic '0' is referred to as Dominant logic.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Systems ArchitectureComputer ScienceISBN:9781305080195Author:Stephen D. BurdPublisher:Cengage LearningA+ Guide to Hardware (Standalone Book) (MindTap C...Computer ScienceISBN:9781305266452Author:Jean AndrewsPublisher:Cengage Learning
Systems Architecture
Computer Science
ISBN:9781305080195
Author:Stephen D. Burd
Publisher:Cengage Learning
A+ Guide to Hardware (Standalone Book) (MindTap C...
Computer Science
ISBN:9781305266452
Author:Jean Andrews
Publisher:Cengage Learning
Understanding Frequency Modulation; Author: Rohde Schwarz;https://www.youtube.com/watch?v=gFu7-7lUGDg;License: Standard Youtube License