Find the heat-transfer rate through the window.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
100°? air flows through a round aluminum tube of ID 60mm and OD 80mm at 4 ?? .The tube is covered in 5mm thick fiberglass insulation. The tube is surrounded by RT air flowing at 5?? over the outside of the insulation. What is the heat rate through the wall of the tube? Assume that the air temperature is constant throughout the tube.
Note: RT is 25 celsius
Air at 25 ° C blows over the hot steel plate whose surface temperature is maintained at 150 ° C. The plates are 50 cm x 40 cm in dimensions and 2.5 cm thick. The convection heat transfer coefficient on the upper surface is 20 W / (m² ° C). The thermal conductivity of steel is 45 W / (m ° C). Calculate the hourly heat loss from the plate surface.
a. heat loss per hour = kJ. Answer
b. If the reverse side surface temperature is maintained, determine the hourly heat loss incurred = kJ.Answer
Calculate the total heat loss from a house measures L×w in plan. The height of walls is H. The house has front and bake external doors, the area of each door is A1m2, and four glass windows with total area of A2m2 the U-value of building elements as the following:
Assume the specific heat capacity of air is CpJ/m3I and the air is changed once per hour. The design internal temperature is T1°C and external temperature is T2°C. Assume the value of N as 0.6. Where
Qf =Σ (U×A×ΔT) watt
Qv= (Cv×N×V×ΔT)÷3600 watt
Chapter 11 Solutions
ENGINEERING FUNDAMENTALS
Ch. 11.2 - Prob. 1BYGCh. 11.2 - Prob. 2BYGCh. 11.2 - Prob. 3BYGCh. 11.2 - Prob. 4BYGCh. 11.2 - Prob. 5BYGCh. 11.2 - Prob. BYGVCh. 11.4 - Prob. 1BYGCh. 11.4 - Prob. 2BYGCh. 11.4 - Prob. 3BYGCh. 11.4 - Prob. 4BYG
Ch. 11.4 - Prob. BYGVCh. 11.6 - Prob. 1BYGCh. 11.6 - Prob. 2BYGCh. 11.6 - Prob. 3BYGCh. 11.6 - Prob. 4BYGCh. 11.6 - Prob. BYGVCh. 11 - Prob. 1PCh. 11 - Prob. 2PCh. 11 - Alcohol thermometers can measure temperatures in...Ch. 11 - Prob. 4PCh. 11 - Prob. 5PCh. 11 - Prob. 6PCh. 11 - Prob. 7PCh. 11 - Prob. 8PCh. 11 - Calculate the R-value for the following materials:...Ch. 11 - Calculate the thermal resistance due to convection...Ch. 11 - Prob. 11PCh. 11 - Prob. 12PCh. 11 - Prob. 13PCh. 11 - Estimate the change in the length of a power...Ch. 11 - Calculate the change in 5 m long copper wire when...Ch. 11 - Prob. 16PCh. 11 - Prob. 17PCh. 11 - Prob. 19PCh. 11 - Prob. 20PCh. 11 - Prob. 23PCh. 11 - Prob. 24PCh. 11 - Prob. 26PCh. 11 - Prob. 27PCh. 11 - Prob. 28PCh. 11 - Prob. 29PCh. 11 - Prob. 30PCh. 11 - Prob. 31PCh. 11 - Prob. 32PCh. 11 - Prob. 33PCh. 11 - Prob. 34PCh. 11 - Prob. 35PCh. 11 - For Problems 11.11, 11.12, and 11.13, calculate...Ch. 11 - Prob. 37PCh. 11 - Prob. 38PCh. 11 - Prob. 39PCh. 11 - Prob. 40PCh. 11 - Prob. 41PCh. 11 - Prob. 42PCh. 11 - Prob. 43PCh. 11 - Prob. 44PCh. 11 - Prob. 45PCh. 11 - Prob. 46PCh. 11 - Prob. 47PCh. 11 - Prob. 48PCh. 11 - Prob. 49PCh. 11 - Prob. 51PCh. 11 - Prob. 52PCh. 11 - Prob. 53PCh. 11 - Prob. 54PCh. 11 - Prob. 55P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- Pls. Answer thank you! A room's sensible space load is from occupants and infiltration, but excluding intentional ventilation, is 3.2 kw. A total of 600 L/s of outside air is required. What is most nearly the room sensible heat ratio?arrow_forwardA room 3.6m x 5m x 8m fully replaces inside air after 3 hours. If the temperature from the outside is 80 F and temperature inside is 60F. Determine the ventilation heat load in Watts. subject Engineering utilities 2arrow_forwardH.WII Cooling Load Estimation An air conditioned room in the Basra city that measures 3 m wide, 3.5 m high and 6 m deep. The window size 1.5 m*1.5 m, mounted on the wall with no external shading and the door size 2m*1m. Calculate the sensible, latent and total heat gains on the room. What is the required cooling capacity? Assume all specification parameters that must be taken into account when calculating cooling load. 6 m 2 *1 m 3 m 1.5 * 1.5 m NW NE LNL E ESE SSW SSF SW SEarrow_forward
- Calculate the thermal resistance due to convection for the following situations: a. warm water with h = 200 W/m2 K b. warm air with h = 10 W/m2 K c. warm moving air (windy situation) h = 30 W/m2 Karrow_forwardA forced air system takes return air at 62 degrees Fahrenheit (°F). It heats theair 59°F. What is the temperature of the heated air blown out to the room?arrow_forwardCalculate the heat loss from a double-pane glass window consisting of two pieces of glass, each having a thickness of 10 mm with a thermal conductivity of k = 1.3 W/m.K . The two glass panes are separated by an air gap of 7 mm. Assume thermal conductivity of air to be k = 0.022 W/m.K .arrow_forward
- Calculate the heat transfer rate (in W) from a 1,180 ft2, 7 in. thick concrete wall with inside and outside surface temperatures of 22°C and 6°C. Warrow_forwardA line was measured using a 50m tape and was recorded as 746.22m. when the average temperature during measurement was 16°C. If the tape is of standard length at 20°C and a coefficient of thermal expansion of 0.0000116m/°C. Compute the correct length of the measured line.arrow_forwardA long rectangular bar (cross section size: 0.36 m x0.13 m, k = 57 W/m K, a= 4.40x10 m/s) is initially at 230°C and is suddenly exposed to a convective environment at 29°C. The heat transfer coefficient is h=35 W/m K. Estimate the temperature at the center of the bar after 10 minutes. How much heat has been lost per unit length from the bar?arrow_forward
- A rectangular lot was measured using a 50-m steel tape at 30 oC. If the recorded length and width of the lot are 197.56m and 105.63m respectively. Determine the Error in the area, if the coefficient of thermal expansion is 0.0000116/ oC and standard temperature of the tape is 25 oC.arrow_forwardA double-pane glass window consists of two pieces of glass, each having athickness of 8 mm, with a thermal conductivity of k = 1.4 W⁄m ⋅ K . The twoglass panes are separated by an air gap of 10 mm, as shown in Figure 11.10 .Assuming the thermal conductivity of air to be k = 0.025 W⁄m ⋅ K , determinethe total R-value for this window. The total thermal resistance of the window is obtained by adding the resistance offered by each pane of glass and the air gap in the following manner:arrow_forwardAssume an inside room temperature of 70°F and an attic air temperature of 15°F, with an exposed area of 885 ft2. Calculate the heat loss (in Btu/h) through the ceiling if the R-19 insulation batt is replaced by R-35 fiberglass insulation.arrow_forward