The incremental fuel costs, in dollars per megawatthour, for two units in a plant are given by dF dF dP, dP, Select one: = 0.007P, +7 and During a 24-h period the load on each unit varies between 100 MW and 500 MW, whereas the plam output varies from 200 MW to 700 MW. (a) At what power level should unit 2 begin to take on all the additional load for the most economic operation of the plant? (b) What is the power output of the plan at this point? Neglect losses. a. a: 122.22MW. b: 222.22KW b. a: 222.22MW. b: 122.22KW ca: 122.22MW, b: 222.22MW = 0.009P₂ + 6

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.31P: Consider two interconnected voltage sources connected by a line of impedance Z=jX, as shown in...
icon
Related questions
Question
The incremental fuel costs, in dollars per megawatthour, for two units in a plant are given by
dF
dP,
dR
dP,
Select one:
= 0.007P, +7 and
During a 24-h period the load on each unit varies between 100 MW and 500 MW, whereas the plant
output varies from 200 MW to 700 MW. (a) At what power level should unit 2 begin to take on all the
additional load for the most economic operation of the plant? (b) What is the power output of the plant
at this point? Neglect losses.
a. a: 122.22MW. b: 222.22KW
b. a: 222.22MW, b: 122.22KW
ca: 122.22MW, b: 222.22MW
d. a: 222.22MW, b: 122.22MW
= 0.009P₂ +6
Transcribed Image Text:The incremental fuel costs, in dollars per megawatthour, for two units in a plant are given by dF dP, dR dP, Select one: = 0.007P, +7 and During a 24-h period the load on each unit varies between 100 MW and 500 MW, whereas the plant output varies from 200 MW to 700 MW. (a) At what power level should unit 2 begin to take on all the additional load for the most economic operation of the plant? (b) What is the power output of the plant at this point? Neglect losses. a. a: 122.22MW. b: 222.22KW b. a: 222.22MW, b: 122.22KW ca: 122.22MW, b: 222.22MW d. a: 222.22MW, b: 122.22MW = 0.009P₂ +6
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Maximum power transfer theorem
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning