(ii) transmission efficiency. [(i) 10.46 kv (ii) 207 A (ii) 95%] 6). A short 3-0 transmission line with an impedance of (5 +j 20) a per phase has sending end and receiving end voltages of 46-85 kV and 33 kv respectively for some receiving end load at a p.f.of 08 lagging. Determine () power output (i sending end power factor [(i) 22-86 kw (ii) 0-657 lag

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.29P: Consider three ideal single-phase transformers (with a voltage gain of ) put together as ...
icon
Related questions
icon
Concept explainers
Question
THESE ARE THE QUESTIONS FROM THE SUBJECT POWER SYSTEM
FUNDAMENTALS AND THE CHAPTER IS PERFORMANCE OF TRANSMISSION
LINES AND THE TOPIC IS SHORT TRANSMISSION LINES THE ANSWERS ARE
GIVEN WITH THE QUESTION PLEASE DO ALL THE QUESTIONS PROPERLY
„DONOT SKIP ANY STEP AND DO YOUR BEST
4.) Estimate the distance over which a load of 15000 kW at 0-85 p.f. can be delivered by
a 3-phase transmission line having conductors of steel-cored aluminium each of
resistance 0-905 O/phase per kilometre. The voltage at the receiving end is to be 132
kV and the loss in transmission is to be 7-5% of the load. [69-55 km]
5). A 3-phase line 3 km long delivers 3000 kw at a p.f. 0-8 lagging to a load. The resistance and reactance
per km of each conductor are 0-40 and 0-3 Q respectively. If the voltage at the supply end is maintained
at 11 kv, calculate:
(i) ceceiving end voltage (line-to-line)
(ii) line current
(ii) transmission efficiency. [(i) 10.46 kv (ii) 207 A (ii) 95%]
6). A short 3-0 transmission line with an impedance of (5 +j 20) 0 per phase has sending end and
receiving end voltages of 46-85 kV and 33 kV respectively for some receiving end load at a p.f.of 0-8
lagging. Determine:
(i) power output
(i sending end power factor [(i) 22-86 kW (ii) 0-657 lag
Transcribed Image Text:THESE ARE THE QUESTIONS FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS AND THE CHAPTER IS PERFORMANCE OF TRANSMISSION LINES AND THE TOPIC IS SHORT TRANSMISSION LINES THE ANSWERS ARE GIVEN WITH THE QUESTION PLEASE DO ALL THE QUESTIONS PROPERLY „DONOT SKIP ANY STEP AND DO YOUR BEST 4.) Estimate the distance over which a load of 15000 kW at 0-85 p.f. can be delivered by a 3-phase transmission line having conductors of steel-cored aluminium each of resistance 0-905 O/phase per kilometre. The voltage at the receiving end is to be 132 kV and the loss in transmission is to be 7-5% of the load. [69-55 km] 5). A 3-phase line 3 km long delivers 3000 kw at a p.f. 0-8 lagging to a load. The resistance and reactance per km of each conductor are 0-40 and 0-3 Q respectively. If the voltage at the supply end is maintained at 11 kv, calculate: (i) ceceiving end voltage (line-to-line) (ii) line current (ii) transmission efficiency. [(i) 10.46 kv (ii) 207 A (ii) 95%] 6). A short 3-0 transmission line with an impedance of (5 +j 20) 0 per phase has sending end and receiving end voltages of 46-85 kV and 33 kV respectively for some receiving end load at a p.f.of 0-8 lagging. Determine: (i) power output (i sending end power factor [(i) 22-86 kW (ii) 0-657 lag
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Transmission line parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning