Chemistry
10th Edition
ISBN: 9781305957404
Author: Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
asap please
1. Assume your analytical method requires a volume flow rate of 2.5 lpm. The required volume is 25 liters to 125 liters. Employees work four hours before lunch and four hours after lunch. What will be your sampling plan? Please explain fully.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- A student would like to prepare a 0.010 M solution from a 1.0 M stock solution with minimal error. The student can choose to do a one-step dilution that uses a 10 mL transfer pipet and a 1000 mL volumetric flask or a two-step dilution using a 50 mL pipet and a 1000 mL volumetric flask for the first dilution, and a 100 mL pipet and a 500 mL volumetric flask for the second dilution. Which method has the smallest overall relative uncertainty and what is the value? **Use table 4.2 on page 70 in your textbook for tolerances of the glassware. O One-step dilution; 0.0020 Two-step dilution; 0.0020 O Two-step dilution; 0.0014 O One-step dilution; 0.0010arrow_forward2arrow_forwardYou are analyzing the effluent from a lotion plant for parabens using HPLC. You have a working standard solution with a concentration of 59.4 ppm which returned a Peak Height of 10,164 and Peak Area of 5,315. You take 44.4 L of the water sample and concentrate it to 0.3 L and analyze this solution. The Peak Height is 9,119 and the Peak Area is 6,320. What is the concentration of parabens in the effluent of the plant in mg/L to two decimal places.arrow_forward
- 02A: 2.1-2.5 and Accuracy Handout (70 min) ulate Figures of Merit for Trueness ▾ Part A. Absolute Error A breathalyzer is a portable electrochemical instrument that measures the concentration of ethyl alcohol in a sample of exhaled breath A forensic chemist checks the calibration of a breathalyzer by testing a standard air sample known to contain 0.174 mg/L of ethanol seven times. The average value of these seven replicate measurements is found to be 0 157 mg/1 Calculate the absolute error of the breathalyzer. 1971 ΑΣΦΑ Submit Previous Answers Request Answer ? Previous x Incorrect; Try Again: 4 attempts remaining Q Search mgl ly Colle 16 of 17 E dx Next 11:44 PM 1/31/202 BANG &arrow_forwardA standard reference material is certified to contain 94.6 ppm of an organic contaminant. Your analysis gives you the follow values, 98.6, 98.4, 95.1 and 97.2 ppm. Can you say with 95% confidence that your values differ from the certified value. Please show workarrow_forward1. A wastewater sample has the following composition: NO3 = 37 mg/L as N CO3²-2.5 x 10 mol/L PO4³ = 10 meq/L Ca²+ = 75 mg/L as CaCO3(s) Express each of the above concentrations in mg/L, mol/L, meq (of charge)/L, and ppm. Make and list any necessary assumptions. Show your work and summarize the results in a table.arrow_forward
- Calculate the concentration (Mdil) of potassium permanganate (KMnO4) when 600 mL (Vconc) of the potassium permanganate solution is added to 400 mL of water. Note: first add the potassium permanganate solution (choose dropper) in the absence of water, move the sensor over the solution, and determine the concentration of the solution prior to adding water (Mconc). Knowing these three pieces of data, you can now calculate (Mail), and enter this calculated number as your answer. You can also confirm your answer by adding 400 mL of water to your 600 mL of potassium permanganate solution and checking the concentration with the sensor (NOTE: the sensor concentration will likely be slightly off the calculated number since it's difficult to add exact volumes in the simulator). Please report your numerical answer only with three significant figures and NO units (eg., 1.23). Mdildil MconcVconc A Rarrow_forwardA standard curve was produced using varying concentrations of KCl and the results are shown below. A sample of pond water was found to have a conductivity of 535 µS/cm. What is the concentration of total dissolved solids in the water sample? Recall the TDS constant is 0.67. CONDUCTIVITY (MICROS 1600 1400 1200 1000 800 600 200 0 Standard Curve of Conductivity vs Concentration Concentrations (M) 0.002 A. 392 mg/L B. 478 mg/L ✓C. 798 mg/L D. 247 mg/L 0.004 y = 132208x + 19.045 R²-0.9996 0.006 CONCENTRATION (M) 0.008 0.01 0.012arrow_forwardWhich is correct? Random errors affect accuracy and systematic errors affect precision. An accurate result shows agreement with the true or accepted value. Precise results can contain significant random error, but little systematic error. The standard deviation is a good measure of accuracy. Polydimethylsiloxane (PDMS) stationary phases have low polarities. Which of the following statements is TRUE about gas chromatography using PDMS stationary phases? The gas chromatography column is typically packed with silica microparticles. An oven is used to control the column temperature because a constant temperature is always needed in gas chromatography Octane (C8H18, boiling point: 126 ºC) is eluted later than dodecane (C12H26, boiling point: 216 ºC) 3-Pentanone ((C2H5)2CO, boiling point: 102 ºC) is eluted later than propanol (CH3CH2CH2OH, boiling point: 97 ºC)arrow_forward
- Part A What mass of KBr (in grams) should you use to make 100.0 mL of a 1.70 M solution of KBr? Express the mass to three significant figures and include the appropriate units. m = Submit 0 μA Value Provide Feedback Request Answer Units ?arrow_forwardE ! G Google Docs: Online Document Editor | Google Workspace Hiranrat_Analysis_CHM235LL DO File Edit View Insert Format Tools Extensions Help A P 100% F1 C Pure A: Pure B: Pure C: Compound 2 F2 Normal text A 146 1 BO с O junk O Crude Fractions. The following table shows a sequence of TLC "lanes" that correspond to fractions collected from a column. After completing the column, a student wants to condense containers while maintaining high purity for each of the components, then what fractions, if any, can be combined to provide # 3 Y 1 2 80 F3 O Times New... Y - 11 + 213 Oo 3 2 0 0 0 0 0 0 0 $ 4 Last edit was 2 minutes ago B IU A UA 45 S Fractions from column 000 F4 6 docs.google.com Hiranrat Analysis_CHM235LL - Google Docs % 5 F5 6 O GOD O O 2 = 2 MacBook Air F6 & 7 6 E 7 F7 Solvent Front Starting Line T 8 DII IE = E 8 9 y DD C F9 pearrow_forward1. As shown below, a student obtains two quality chromatograms for her distillate and pot samples, containing methanol and cyclohexanol. Match Chromatograms A and B with distillate or pot, and explain your conclusion. Circle your response: Chromatogram A A: Distillate or Pot Explain your answer: t=0 Chromatogram B B: Distillate or Potarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- ChemistryChemistryISBN:9781305957404Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCostePublisher:Cengage LearningChemistryChemistryISBN:9781259911156Author:Raymond Chang Dr., Jason Overby ProfessorPublisher:McGraw-Hill EducationPrinciples of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
- Organic ChemistryChemistryISBN:9780078021558Author:Janice Gorzynski Smith Dr.Publisher:McGraw-Hill EducationChemistry: Principles and ReactionsChemistryISBN:9781305079373Author:William L. Masterton, Cecile N. HurleyPublisher:Cengage LearningElementary Principles of Chemical Processes, Bind...ChemistryISBN:9781118431221Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. BullardPublisher:WILEY
Chemistry
Chemistry
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Cengage Learning
Chemistry
Chemistry
ISBN:9781259911156
Author:Raymond Chang Dr., Jason Overby Professor
Publisher:McGraw-Hill Education
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Organic Chemistry
Chemistry
ISBN:9780078021558
Author:Janice Gorzynski Smith Dr.
Publisher:McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry
ISBN:9781305079373
Author:William L. Masterton, Cecile N. Hurley
Publisher:Cengage Learning
Elementary Principles of Chemical Processes, Bind...
Chemistry
ISBN:9781118431221
Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:WILEY