Chapter 10, Problem 10.4P
To determine
Overall heat transfer coefficient considering fouling factor.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A liquid (SG = 0.8 and μ = 5 CP = 0.00336 lbm/ft s) from a solvent recovery plant is being pumped
from a vessel into a reactor. The flow rate to the rector is 100 GPM (0.2228 ft³/s,) and the line,
schedule 40-carbon steel (a = 0.0018 in). The pressure in the vessel is 15 psig and the reactor is
pressurized to 65 psig. The flow into the reactor is 25 ft below the level in the vessel as shown in
the drawing. The centrifugal pump is located 5 ft below the level in the vessel.
The piping consists of the following:
Suction line
10 ft of 2.5"
Pipe
Gate valves
90 degree elbows
Check valves
2" sch 40 pipe
2.5" Sch 40 pipe
Gate valve
Check Valve
90° elbows
2
2
1
ID = 2.067"
ID=2.47"
K = 8 ft
K= 100 fr
K = 30 ff
Discharge line
325 ft of 2"
2
5
none
Acs=0.0233 ft²
Acs = 0.0332 ft²
a. Determine the velocity in the 2.5" and 2" lines (ft /s).
b. Determine the losses due to friction in both the suction and discharge lines (ft lbi/lbm).
c. Estimate the amount of total dynamic head required of the pump…
• A 6 MW generator had a thrust of 103,000 lb. The outside diameter
of the step bearing is 12 in, and the inside diameter is 8 in. Employ a
film thickness of 0.004 in. Use SAE 20 oil at 120 , the specific heat of
the oil being 0.6 BTU/lb deg F, and density of 0.307 lb/cu. in
Determine:
(d) Temperature rise
A heat exchanger with an effectiveness of 75 percent is used to heat 5 kg/s of water from
2. (
50 °C with condensing steam at 1 atm. Calculate the area for U = 1200 W/m2.°C. Suppose fouling
occurred on both the tube and shell side with the following fouling factors, Rwater = 0.0002 m2-°C/W,
and Risteam = 0.00009 m2. °C/W, what will be the new exiting temperature of the water?
Chapter 10 Solutions
Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
Ch. 10 -
10.1 In a heat exchanger, as shown in the...Ch. 10 - Prob. 10.2PCh. 10 -
10.3 A light oil flows through a copper tube of...Ch. 10 - Prob. 10.4PCh. 10 - Water flowing in a long, aluminum lube is to be...Ch. 10 - Mot water is used to heat air in a double-pipe...Ch. 10 - Prob. 10.7PCh. 10 -
10.8 The heat transfer coefficient of a copper...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A 40 mm diameter shaft is made of steel 50C4 (Sut 660 N/mm²) and has machined surface. The expected reliability is 99%. The theoretical stress concentration factor for the shape of the shaft is 1.6 and the notch sensitivity factor is 0.9. Determine the endurance limit of the shaft.arrow_forwardA highly engineered Ecto-Containment System Protection Grid produces about 8 kW of waste heat in thesystem. A less highly-engineered tubular cross-flow heatsink is designed to dissipate that heat. In this case, the heat sink is a single long pipe carrying anti-freeze through the unit. The pipe has an OD of 80mm and and ID of 16mm. Assume that there is no resistance between the anti-freeze and the OD of the pipe (infinite conduction). Convection is forced, with an airflow of 12 m/s air across it Pr,air = 0.72, density(p) = 1.2 kg/m3, u = 16.83x10−6 Pa − S, k = 0.025 W/mk). The outside air is at 25℃ while the antifreeze is at 180℃. a) Find the Reynold’s Number of flow over the Pipe b) Find the convection coefficient across the pipe c) How long must the pipe be to dissipate all 8kW?arrow_forwardQ3/ For a flat plate collector having the following characteristics as shown in the table; calculate (a) Fin efficiency, (b) Collector efficiency factor, (c) Useful energy, (d) Overall efficiency. Overall loss coefficient 6.9 W/m2 C° Heat transfer 32 W/m C° coefficient inside the tubes Tube spacing Tube outside diameter 120 mm Collector area 4 m 15 mm Flow rate 0.06 kg/s Tube inside diameter 13.5mm τα 0.8 Plate thickness 0.4 mm Global solar radiation 2,88 MJ/m2 for lh Alloy of aluminum, 130 W/m C° Temperature difference 5 C° operating Plate material, k at 20C°arrow_forward
- A leaf filter filtering a slurry, gave a total of 8 m³ filtrate in 30 minutes. Filtration was continued till 11.3 m³ of filtrate was collected. Estimate the washing time in minutes, if 11.3 m³ of wash water are used. The resistance of the cloth can be neglected and a constant pressure is used throughout.arrow_forwardCalculate the critical and actual heat flux for pool boiling of water at 2.1 bar from a surface at 130 °C. Take: Saturation temperature =123 °C PL= 941.6 kg/m', pv=1.18 Ca= 4.25 KJ/kg.°C K=687*10 W/m°C HL=230*10“ Ns/m2 2=2198 KJ/Kg 0=55*10 N/m Pw at 125°C = 2.5*10$ N/m² P,=2.25*10 N/m²arrow_forward* It required to design a ducting system to condition the building shown in figure (1). The uantity of outdoor is (20%) of supply air. Using information in table, find 1- The sensible and latent load for cooling coil. 2- The quantity and condition of supply air to each place. 3- By using equal pressure drop method, design the rectangular ducting system with maximum height side (600mm). 4- Illustrate the all process on psychometric chart. Outdoor 45 °C db & 30% RH Out let type Celling conditioning indoor conditioning 24 °C db & 50% RH diffuser Number of diffuser 2 for each place 15 kpa 10 kpa 15 kpa By pass factor Apparatus dew point 9°C Ap losses diffuser Ap losses filter Ap losses coil 0.15 R/w 1.5 6m 6m 6m Room (1) Room (2) Room (3) 4m RSH=8KW RSH=6KW RSH=8KW RLH=2KW RLH=1KW RLH=2KW 2m AHU Mechanical Room (4) RSH=20KW 4m Room RLH=3KW 4m 14marrow_forward
- * It required to design a ducting system to condition the building shown in figure (1). The uantity of outdoor is (20%) of supply air. Using information in table, find 1- The sensible and latent load for cooling coil. 2- The quantity and condition of supply air to each place. 3- By using equal pressure drop method, design the rectangular ducting system with maximum height side (600mm). 4- Illustrate the all process on psychometric chart. Outdoor 45 °C db & 30% RH Out let type Celling conditioning indoor conditioning 24 °C db & 50% RH diffuser Number of diffuser 2 for each place 15 kpa 10 kpa 15 kpa By pass factor Apparatus dew point 9°C Ap losses diffuser Ap losses filter Ap losses coil 0.15 R/w 1.5 бm бm бm Room (1) Room (2) RSH=6KW Room (3) 4m RSH=8KW RSH=8KW RLH=2KW RLH=1KW RLH=2KW 2m AHU Mechanical Room (4) RSH=20KW 4m Room RLH=3KW 4m 14marrow_forwardBA4s6nknAPkVXhnUEg rmResponse Good Luck... PROBLEM 1 Determine the following: a. Enclosed Area b. Perimeter of the thin walled tube Given is a thin-walled tube with the following data: Wall thickness-2mm ABC is a sector with a radius of 50 mm AOD & COD is a triangle C. Shear flow d. Shear stress e. Angle of twist Torque is 1000 N.m Length of the thin walled tube is 0.5 m Use G=24 GPa for aluminium A 90 B D 3R PROBLEM 2 Determine the following: a. Enclosed Area b. Perimeter of the thin walled tube c. Shear flow d. Shear stress Given is a thin-walled tube with the following data: Wall thickness- 3mm Torque is 900 N.m Length of the thin walled tube is 1.2 m. Use G=24 GPa for aluminium e. Angle of twist Ps Xd étv Warrow_forward-Explain in details the working principle of the Pitot tubearrow_forward
- 2, The internal diameter of a boiler generating tute is 4in. and the wall thickness is 0.375 in. In operation the external surrace film temperature is 26 Btu/hr . ft².°F, the internal film coefficient is 1700 Btu/hr.ft².°F and a 0.375 in. thickness scale having a conductivity of 0.6 Btu/hr.ft. °F is deposited on the inner surface of the tube. The metal conductivity is 26 Btu/hr.ft. °F, the furnace gas temperature is 2100 °F and the temperature of the water is 500 °F, calculate (a) the overall coefficient of heat transfer for the clean tube, (b) the overall heat transfer coefficient including the effect of the scale, (c) the external tube surface temperature before and after the scalearrow_forward3. A 2-shell 4 tube pass HE will be used to cool a hot fluid from 400oC to 200oC using a cooling water available at 80oC and heated at 180oC. Calculate the total heat transferred if the tubes are 50mm med wt. steel, 5 m long per pass. Assume hi = 200W/m2K and ho = 4500W/m2Karrow_forward3. A 6 in x 20 ft uninsulated B.I pipe conveys steam at 385 °F with an average ambient temperature of 85°F. if the cost of the fuel is PhP 250.00 per 106 BTU with the net energy conversion efficiency of 75%, what is the annual cost of the heat lost? For 6 in. pipe schedule 80:Do = 6.625 inDi = 5.761 in For iron:k = 30 BTU/ hr ft °F for the surface coefficients:hi = 1000BTU/ hr ft2°F ho = 2 BTU/hr ft2 °Farrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY