Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN: 9781305387102
Author: Kreith, Frank; Manglik, Raj M.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 10, Problem 10.2P
To determine
Over all heat transfer coefficient based on inner and outer surface areas of the heat exchanger considering fouling factor.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A heat exchanger with an effectiveness of 75 percent is used to heat 5 kg/s of water from
2. (
50 °C with condensing steam at 1 atm. Calculate the area for U = 1200 W/m2.°C. Suppose fouling
occurred on both the tube and shell side with the following fouling factors, Rwater = 0.0002 m2-°C/W,
and Risteam = 0.00009 m2. °C/W, what will be the new exiting temperature of the water?
-Explain in details the working principle of the Pitot tube
A thick-walled cylinder tubing of hard rubber having an inside radius of 20mm is being used as temporary cooling coil in a bath. Ice water is flowing rapidly through inside tube and the inside wall temperature is 274.9K. The outside surface temperature is 297.1K. A total of 14.65W must be removed from the bath by cooling coil. How many m of tubing are required?
Chapter 10 Solutions
Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
Ch. 10 -
10.1 In a heat exchanger, as shown in the...Ch. 10 - Prob. 10.2PCh. 10 -
10.3 A light oil flows through a copper tube of...Ch. 10 - Prob. 10.4PCh. 10 - Water flowing in a long, aluminum lube is to be...Ch. 10 - Mot water is used to heat air in a double-pipe...Ch. 10 - Prob. 10.7PCh. 10 -
10.8 The heat transfer coefficient of a copper...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A shell-and-tube heat exchanger is made of two standard steel tubes, as shown in Fig. 9.13 . The outer tube has an OD of 7/8 in and the OD for the inner tube is ½ in. Each tube has a wall thickness of 0.049 in. Calculate the required ratio of the volume flow rate in the shell to that in the tube if the average velocity of flow is to be the same in each. Answer is Qshell/ Qtube= 2.19. Please show how to solve.arrow_forwardIn a heat exchanger, water flows through a long copper tube (inside diameter 2.2 cm) with an average velocity of 2.13 m/s. The water is heated by steam condensing at 150 degree celsius on the outside of the tube. Water enters at 15 degree Celsius and leaves at 60 degree Celsius . What is the heat transfer coefficient, h, for the water? Write the given, required and solutionarrow_forwardThe clean U for an exchanger is 770 BTU/(hr 0 F ft2). Its tube area is 550 ft2. After operating for several months, it is heating water from 40 0F to 150 0F at a flow rate of 200 GPM with a heating fluid on the shell entering at 300 0F and exiting at 170 0 F. Has the overall U decreased significantly? how many 1.0 inch diameter, 20 ft long tubes would it take to equal the 550 ft2 area?arrow_forward
- 11 MWth plant operates at a thermal efficiency of 34%. The waste heat is dumped across a condenser which operates at a shell side pressure of 0.717 psia. For the given information below, determine the condenser tube length. A Coolant Flow Rate 4.81 x 108 Ibm/hr Coolant Inlet Temperature 60 F Number of Tubes 62,832 Lattice triangular Pitch 1.5 inch Tube OD 1 inch Tube ID 0.944 inch Tube Thermal Conductivity 10 Btu/hr-ft-F Condensing Heat Transfer Coefficient 1228 Btu/hr-ft²-Farrow_forwardExplain the impact of pipe roughness on the friction loss through a piping system under both laminar and turbulent flow conditions.arrow_forwardEvaluate the Reynolds number for flow over a tube from the following data: D=6cm,U=1.0m/s, =300kg/m3,=0.04Ns/m2.arrow_forward
- Flow Characteritistics( Enternce Effect) Why was there some diagrement between the actual Pitot tube velocity profile and the power law velocity profile?arrow_forward4. A heat exchanger creates energy loss in the fluid system shown below. Water at 50°C flows vertically upward at a constant volume flow rate of 6 x 10-3 m³/s. A mercury manometer is used to measure pressure difference between points 1 and 2. Evaluate the total energy loss (in a unit of m) between points 1 and 2. Using the velocity in the inlet tube, evaluate the minor loss coefficient K corresponding to the heat exchanger. The pipe geometry and mercury manometer setup are indicated in the figure. In the figure, OD indicates the outer diameter of pipe. The specific weights of water and mercury are water = Pwater9 = 9.81 kN/m³ and 133.7 kN/m³, respectively. Ignore the volume flow rate of water into or out of the mercury manometer, but one cannot ignore the contribution of water to the manometer measurement. A Flow 1200 mm Y Water 100-mm OD X 3.5-mm wall steel hydraulic tube Heat exchanger. 1250 mm 350 mm Y Mercury -50-mm OD x 2.0-mm wall steel hydraulic tubearrow_forward10. Recall when you were collecting data for the Entrance Loss experiment, there was a ten second delay before the data was posted in Excel. Why was there a delay, and why was it important? 11. Were your theoretical entrance loss factors, KL, higher or lower than your experimental value? What may be some causes for each entrance type? Concentric Tube Heat Exchanger 12. Why was it difficult to achieve steady-state conditions? 13. List at least two assumptions that are being made in the Heat Exchanger experiment, and explain the reasons why they are approximations. 14. What are thermal and hydrodynamic entrance lengths? Are either (or both) of them an issue for the experiment? Why or why not?arrow_forward
- A (fluid 1) at the rate of 145 Ib/min is heated 75 °F to 150 °F by another fluid (fluid 2) enters the exchanger at 215 °F and leaves at 159 °F.(Fluid 2)making one shell pass and the (fluid 1) making two tubes pass. Due to fouling the heat transfer drops by 7% and the value of fouling factor is 0.0012. Calculate the outlet temperatures, I f the Cp to the both fluids are = 0.98 Btu/ Ib .° F, flow is counter current. Area of the heat exchanger is 98 ft2 and thearrow_forwardConcentric tube heat exchanger (tubular or tube in tube) is used for a large industrial gas turbine. The dimensions and values are given. One of the steps is not required to find the required length of the HX, if the oil leaves at 60 C? Oil and water inlet temperatures are 100 and 30 C, respectively. Log mean temperature difference Overall heat transfer coefficient Thermal entry length to validate the steps None of the above Reynolds number, Prandtl number and Nusselt numberarrow_forwardA liquid (SG = 0.8 and μ = 5 CP = 0.00336 lbm/ft s) from a solvent recovery plant is being pumped from a vessel into a reactor. The flow rate to the rector is 100 GPM (0.2228 ft³/s,) and the line, schedule 40-carbon steel (a = 0.0018 in). The pressure in the vessel is 15 psig and the reactor is pressurized to 65 psig. The flow into the reactor is 25 ft below the level in the vessel as shown in the drawing. The centrifugal pump is located 5 ft below the level in the vessel. The piping consists of the following: Suction line 10 ft of 2.5" Pipe Gate valves 90 degree elbows Check valves 2" sch 40 pipe 2.5" Sch 40 pipe Gate valve Check Valve 90° elbows 2 2 1 ID = 2.067" ID=2.47" K = 8 ft K= 100 fr K = 30 ff Discharge line 325 ft of 2" 2 5 none Acs=0.0233 ft² Acs = 0.0332 ft² a. Determine the velocity in the 2.5" and 2" lines (ft /s). b. Determine the losses due to friction in both the suction and discharge lines (ft lbi/lbm). c. Estimate the amount of total dynamic head required of the pump…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning