For three-phase power measurements test if the value of the line voltage source equal to 220 volt and the value of balance resistive star connected equal to 920, the reading of the three-phase wattmeter equal to .. O 0.138 W 52.61 W O 17.54 W
Q: How many wattmeters would be needed to measure the total three-phase power in a balanced three-phase…
A: In this questions, we need to tell about the how many wattmeter is required to measur the power in…
Q: For an ac three-phase four wire system, having a voltage of 415 V, with load of 120 kW and…
A: Given three phase four wire systemHaving voltage V=415 vLoad P=120 kw Resistance R=0.05 ΩPower…
Q: The desired secondary voltage is 115 volts l, 3-phase, to monitor the voltage of 230 kV line and…
A:
Q: Two wattmeters are connected into a 3-phase, 3-wire, 220V line indicate 3.5kW and 1.5kW. If the…
A:
Q: Three similar resistors connected in star draw a line current of 10 A from a 380-V, 3-phase mains.…
A: Given: Line-to-line voltage VL = 380 V, Line current IL = 10 A. For a star-connected system, For…
Q: 1. Discuss the features of two-wattmeter method of power measurement. 2. What is the significance of…
A:
Q: With neat diagram, discuss the 3-phase power measurement using three wattmeter method and write down…
A: Three wattmeter method is used to measure the power in a 3-phase system. In this method, the power…
Q: phase from a 3-phase, 400 volts balanced supply system. The line current is 20 A and power taken by…
A:
Q: A balanced 3 phase load draws 75 amperes line current at 230 volts line to line and 0.848 lagging…
A: In this question, A balanced 3 phase load draws 75 amperes line current V=230 volts line to line…
Q: Over sting of 3- phase transmission line has 4 insulators and Ce=0.15C. If the voltage between the…
A:
Q: 6.5 EDG Loading An EDG loads are: 20% Constant impedance. 70% constant kVA, 10% constant current…
A: Given: Z=20% 70% KVA 10% constant current Considering p.u. value considering the EDG is three phase…
Q: A balanced 3 phase star connected load draws power from a 410 V supply. Two wattmeter's indicate…
A: When the reverse switch being operated on the meter then we take the reading value as negative.
Q: A single-phase 9 kV, 60 Hz, 100 kVA, transmission line consists of two hard- drawn aluminium…
A: Single phase transmission line Resistivity of wire and radius of wire given in the question. Find…
Q: A Current Transformer with a ratio of 50:2 and a PT with a ratio of 100:1 are connected to the…
A: A transformer is an electrical machine which is used in AC circuit to either step up or step down…
Q: A wattmeter with a current coil connected to phase A, and the voltage between phase A and C gives a…
A: Since, the value of the current for each phase is different that means the system represents the…
Q: A 3-phase Wye-Delta Connected source to load system has the following particulars: Load impedance…
A:
Q: -What are the reasons for using three phase system to generat and distribute electrical power.
A: In three-phase distribution, phase current is distributed in the phase of 120 degree due to which…
Q: In a balanced two-phase voltage system, the different phase voltage is 120 Volts. What is the…
A: According to the question we have to find the value of line to line voltage with the help of given…
Q: What is reading of both wattmeter, when measuring the power of three-phase three wire system having…
A: Given: Input power, P1+P2=5 kW ..... 1 Power factor, cosϕ=0.866
Q: In two wattmeter 3-phase power measurement method, if the two wattmeter readings are equal then the…
A: Therefore, if the two wattmeter readings are equal then power factor of the circuit is unity (1).…
Q: 4, 11 A 16/ KVA, 13200:240 volt single phase R. foad trans former has 0.01035 ohm and X" with 13,200…
A: In this question, We need to determine the ZR and Zx , copper losses, and efficiency at the 80%…
Q: A 400 volt, three-phase is connected to a balanced loạd of three impedances each consisting 20-ohm…
A: It is given that: VL=400 VR=20 ΩXL=15 Ω
Q: 6. In a balanced three-phase, 208 V circuit, the line current is 100 A. The power is measured by two…
A: In this question we need to choose a correct option
Q: What is the reading (in kW) of both the wattmeter, when measuring the power of a three-phase three…
A: Given- Three-phase three wire systemInput power=5 kWPower factor=0.866To Find-The reading of both…
Q: 2) Three similar coils, each having a resistance of 4.20and an inductive reactance of 4.46Qare…
A: Calculate the phase voltage of the supply,
Q: n balanced star (wye) connected system, the line voltage is
A: THREE PHASE-BALANCED STAR OR WYE CONNECTION: 1. A central connecting point connecting one side of…
Q: What is the significance of a negative indication of a wattmeter reading using the two-wattmeter…
A: In this question we will write significance of a negative indication of a wattmeter reading using…
Q: . A wattmeter reads 5,540 W when the current coil is connected in phase a and the voltage coil is…
A: Consider the formula for the power in a three phase system is three times the power of the single…
Q: three-phase generator supplied 3.0 kVA at a power factor of 0.8 lagging. If 2200 W are delivered to…
A: Given data : Power factor, Pf=0.8Pload=2200 W Power Supplied is given by 3 KVA= 3000 VA
Q: A balanced 3 phase star connected load draws power from a 420 V supply. Two wattmeter's indicate…
A: Active power=W1+W2 reactive power =3×(W1-W2) power factor=cos arctan(Reactive powerActivepower)
Q: In a balanced 220-volt 3-phase circuit, two wattmeters are connected to measure power. If the…
A: Given readings of two wattmeter, W1= 8.53 kWW2= -2.66 kW
Q: 8. A 415-V, 3-phase, 4-wire system supplies power to three non-inductive loads. The loads are 25 kW…
A:
Q: A balanced 3 phase star connected load draws power from a 430 V supply. Two wattmeter's indicate…
A: Here, we have given some information about the balanced three-phase star-connected load. The load…
Q: A balanced four-phase star connected load has a phase voltage of magnitude 150 volts. What is the…
A: Answer shown below.
Q: 0 A 250 KVA, 440-volt, three-phase load is to be supplied from a 2,300 volt, three-phase line.…
A: Transformer is work on the principle of faraday electromagnetic induction. Transformer is static…
Q: A 3-phase y connected balance load impedance of 3+j2 and a supply of 460 volts, 60 Hz mains.…
A:
Q: Must you see two wattmeters to measure the total three-phase power on a balanced three-phase…
A: In this question we discuss about two wattmeters to measure the total 3-phase power.
Q: In a three phase star connected system, the line voltage is 330.2 volt, find the R phase voltage?
A:
Q: In the experiment No.1, the power measurement using two wattmeter method for star connected load,…
A:
Q: b) Two wattmeters are connected to measure the input to a 400 V, three phase delta connected motor…
A: Given, Two wattmeter are connected to measure input having, Voltage, V= 400 V Output power, Po/p=…
Q: Simple summary about the measurement of power in a 3 Phase AC circuit using a two-wattmeter.…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: (b) For the balanced three phase system shown below, it is determined that 200W is dissipated is…
A: Convert the delta load to equivalent star loadThe equivalent load impedance in star connection…
Q: 3) Three similar coils, each having a resistance of 8 and an inductive reactance of 8 are connected…
A:
Q: 1. If two wattmeters are used to measure total power in a three-phase three-wire system does each…
A: NOTE- As per the rules we can answer only 3 sub-parts, please post the remaining sub-parts as the…
Q: The current flows in the windings of the DC machine which causes the Hysteresis loss Friction loss…
A: Eddy current losses are the cause of Faraday's law which states that, “Any change in environment of…
Q: Q2: A. Three similar resistors connected in star draw a line current of 10 A from a 380-V, 3-phase…
A:
Q: 5. A 400 volt, three-phase is connected to a balanced load of three impedances each consisting of 20…
A: line current= phase current=phase voltagephase impedance. in case of star connection line…
Q: A 7.5 HP 230 volt three phase motor takes a line current of 18.4 A when operating at rated output at…
A:
Q: ) Two wattmeters connected to measure the input to a balanced three-phase circuit indicate 2500 W…
A:
Step by step
Solved in 3 steps with 3 images
- Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage windings are connected in Y. (a) For the low-voltage side, connect the windings in , place the polarity marks, and label the terminals a, b, and c in accordance with the American standard. (b) Relabel the terminals a, b, and c such that VAN is 90 out of phase with Va for positive sequence.I need answer in 30 minutes else it's no meaning A 3-phase, 20 MVA, 10 kV alternator has internal reactance of 5% and negligible resistance. Find the external reactance per phase to be connected in series with the alternator so that steady current on short-circuit does not exceed 8 times the full load current.Explain the concept of power quality and the impact of voltage sags, harmonics, and other issues on electrical equipment.
- a)Why are transformers generally connected in parallel at a substation?b)What conditions must be met for two transformers to be paralleled?c)Draw the phase relationship and connection diagram for Dd0 connection andYy6Determine the short-circuit current ISC3,0.4kV for a 3-phase short- circuit fault at F. Give your answer up to 2 decimal in kA but do not enter the unit in your answer. Transformer T1 Transformer T2 Cable C1 Isc3,6.6kV Isc3.0.4kV O + j0.150 F 1 MVA 2 MVA 22/6.6kV 25 MVA fault level 6.6 kV/400V Z=3% 6.6 kV switchboard 400 V switchboardWhat are two main types of three-phase connections
- Grounding methods in Power systemsA three phase,Y connected, 215 V (line to line), 7.5 kW, 60 Hz, three pole IM has the following parameter values in Ohm/phase referred to the statorR₁ = 0.294 Ohm, R₂ = 0.144 Ohm, X₁ = 0.203 Ohm, X₂ = 0.409 Ohm, Xm = 10.25 Ohm.The total friction,windage and core losses may be assumed to be constant at 350 W independent of load. For a slip s = 0.02, compute the followingsa) Stator Currentb) Power Factor(pf)c) Rotor Speedd) Power Output(Shaft)e) Output(Shaft) Torquef) Efficiency(n)Q2\ Two generators G1 & G2 are rated 15 MVA, 11 kV and 10 MVA, 11 kV respectively. The generators are connected to a transformer as shown in the following figure. Find the sub- transient current in each generator when a three-phase fault occurs on the high voltage side of the transformer. A/Y 15 MVA, 11 kV, X"gl=j0.10 pu G2 15 MVA, 11/66 kV, Xr-j0.06 pu 10 MVA, 11 kV, X"g2-j0.10 pu
- e = 0 Q1: What does happen if we change two currents? a. Q2: What does happen if we have a three-phase four poles machine? Q3: What does happen if we have a two-phase two poles machine? e = 0 Q4: What does happen if we apply a capacitance in phase b and then use same voltage for both phase. Dr. Ali Ki. pw --Discuss the advantage and disadvantage of each connection. Generator reactor Tie-bar reactor (series) Ring reactor (Parallel)Why transformer rating in kva