Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 8, Problem 8.4.11P
To determine
(a)
The adequacy of weld using load and resistance factor design (LRFD) method.
To determine
(b)
The adequacy of weld by using allowable strength design method.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Considering the following steel connection. The plates in Pink are 9mm steel plates. The middle plate (Yellow) is
18mm thick. The width of the plate is 100mm. The maximum allowable tension stresses on any of the plates is
100Mpa in Gross Area Yielding and 150 Mpa for Net Area or Tension Rupture. The bolts used are 8mm in
diameter, the holes are 10mm in diameter, no need to add 1.6mm. The bolts allow a maximum of 280 Mpa of
shear. Determine the maximum allowable "P" of the connection in kN.
4-47.
The support consists of a solid red brass C83400 copper
post surrounded by a 304 stainless steel tube. Before the
load is applied the gap between these two parts is 1 mm.
Given the dimensions shown, determine the greatest axial
load that can be applied to the rigid cap A without causing
yielding of any one of the materials.
mm
0.25 m
SOLUTION
60 mm
-10 mm
Determine the maximum service load P that can be resisted safely by the welded connection shown. Use ASD.
E80
10
150
300
200
Chapter 8 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 8 - Prob. 8.2.1PCh. 8 - Prob. 8.2.2PCh. 8 - A plate is used as a bracket and is attached to a...Ch. 8 - Prob. 8.2.4PCh. 8 - Prob. 8.2.5PCh. 8 - Prob. 8.2.6PCh. 8 - Prob. 8.2.7PCh. 8 - Prob. 8.2.8PCh. 8 - Prob. 8.2.9PCh. 8 - Prob. 8.2.10P
Ch. 8 - Prob. 8.2.11PCh. 8 - Prob. 8.2.12PCh. 8 - Prob. 8.2.13PCh. 8 - Prob. 8.3.1PCh. 8 - Prob. 8.3.2PCh. 8 - Prob. 8.3.3PCh. 8 - Prob. 8.3.4PCh. 8 - Prob. 8.3.5PCh. 8 - Prob. 8.3.6PCh. 8 - Prob. 8.3.7PCh. 8 - Prob. 8.3.8PCh. 8 - Prob. 8.3.9PCh. 8 - Prob. 8.3.10PCh. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Prob. 8.4.4PCh. 8 - Prob. 8.4.5PCh. 8 - Prob. 8.4.6PCh. 8 - Use an elastic analysis and compute the extra load...Ch. 8 - Use an elastic analysis and compute the extra load...Ch. 8 - Prob. 8.4.9PCh. 8 - Prob. 8.4.10PCh. 8 - Prob. 8.4.11PCh. 8 - Prob. 8.4.12PCh. 8 - Prob. 8.4.13PCh. 8 - Prob. 8.4.14PCh. 8 - Prob. 8.4.15PCh. 8 - Prob. 8.4.16PCh. 8 - Prob. 8.4.17PCh. 8 - Prob. 8.4.18PCh. 8 - a. Use LRFD and design a welded connection for the...Ch. 8 - Prob. 8.4.20PCh. 8 - Prob. 8.5.1PCh. 8 - Prob. 8.5.2PCh. 8 - Prob. 8.5.3PCh. 8 - Prob. 8.5.4PCh. 8 - Prob. 8.5.5PCh. 8 - Prob. 8.6.1PCh. 8 - Prob. 8.6.2PCh. 8 - Prob. 8.6.3PCh. 8 - Prob. 8.6.4PCh. 8 - Prob. 8.7.1PCh. 8 - Prob. 8.7.2PCh. 8 - Prob. 8.7.3PCh. 8 - Prob. 8.8.1PCh. 8 - Prob. 8.8.2PCh. 8 - Prob. 8.8.3PCh. 8 - Prob. 8.8.4P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- One plate of size 100 mm x 12 mm is lap joined to another plate of size 200 mm x 12 mm by fillet weld of size 10 mm. Lap length is 100 mm. Fillet weld is provided on all the three sides of the smaller plate. Determine the maximum axial tension the joint could carry. Assume the plates are of mild steel of grade 250 N/mm?.arrow_forwardQ3. A solid shaft was made of alloy steel, it was welded to a flat plate by a specific size of fillet weld. If a torque is applied to the shaft, calculate the size of the weld joint.arrow_forwardThe truss below is pin connected at A and E, and is acted on by the forces shown. E A D B Identify all of the ZERO-FORCE MEMBERS by checking the boxes below (if there are none, leave all boxes unchecked): BF AF BC BH CD EG -GH AB CH DG DH DE -FHarrow_forward
- Determine the design tensile strength of plate (200x8 mm) connected to 10-mm thick gusset using 20 mm bolts as shown in the figure, if the yield and the ultimate stress of the steel used are 250 MPa and 410 MPa, respectively. Add 1mm around the bolt for the hole. Use LRFD method. Plate 8-mm thick 2 3 40+ 30 301 T 200 mm Gusset 10-mm thick 3af 30 2_3 *40 40+ 50,54 +40arrow_forwardA bracket connection shown in figure, consists of a joist cutting welded to the flange of a column by shop fillet welds 8 mm on flanges and 6 mm on the web. Determine the safe service load 'W', the bracket can support at a distance of 200 mm from the face of the column if the steel grade is Fe 410. 200 200 8V 150 200 W 8 V 150 N 150 200 250 Partial factor of safety on shop weld = 1.25 Yield strength of steel = 250 MPa. 250 Aarrow_forwardQ3-1 (Trusses), For the Figure shown below; 1 1. Find the forces in the members AB and AD of the truss and indicate whether it is in tension or 3m compression. 10KN 2. Read the following paragraph carefully then answer if it's TRUE or FALSE: The force in the member BC equal to zero? 3. Read the following paragraph carefully then CHOOSE THE CORRECT English Fried Safe 10KN 15 AN 3m 20 kNarrow_forward
- Topic:Bolted Steel Connection - Civil Engineering *Use latest NSCP/NSCP 2015 formula to solve this problem *Please use hand written to solve this problem The bracket shown in the figure is supported by four 22 mm diameter bolts in single shear. The bracket is subject to an eccentric load of 150 kN. Use LRFD. Use A36 steel. Questions a) Determine the critical force on the most stressed bolt. b) Determine the nominal shear stress of the most stressed bolt.arrow_forwardThe connection shown is subjected to a tensile force of P = 100 kN. The allowable shear stress for the bolts is 100 MPa. Assume each bolt supports an equal portion of the load. Determine the required diameter of the bolts. a. 20.6 mm b. 25.2 mm c.35.7 mm d.17.8 mm choose letter of correct answerarrow_forwardThe light rigid bar ABCD shown is pinned at C and connected to two vertical rods. The bar was initially horizontal, and the rods were stress-free before the load P = 20 KN is applied. Steel E200 Gra A-600mm L-I m 2.0 m 0.6m 1.5 m D. V P-20 KN Aluminum E-70 GPa A-900mm L-1.5 m What is the axial load at aluminum rod in KN?arrow_forward
- Determine the maximum service load P that can be resisted safely by the welded connection shown. Use ASD. E80 10 150 300 K. 200arrow_forwardA tension plate shown below is used to support suspended load "T". Gusset Plate Fy Fu = 400 MPa = 248 MPa 200 mm a) Determine the allowable tensile capacity of the plate if L = 240 mm. (Assume weld strength is satisfactory).arrow_forwardA bolted connection shown consists of two plates 300mm x12mm connected by 4 - 22 mm diameter bolts. Edge distances = 75mm dhole for tensile and rupture = db + 3 mm dhole for bearing strength for Lc = db + 1.5 mm Fy = 248 Mpa Fu = 400 Mpa Fn = 330 Mpa Use LRFD design method. Determine the design strength due to the gross yielding of plates. (kN)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning