Sustainable Energy
2nd Edition
ISBN: 9781337551663
Author: DUNLAP, Richard A.
Publisher: Cengage,
expand_more
expand_more
format_list_bulleted
Concept explainers
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Calculate the decrease in heat loss in kilowatt-hours per day when a 1.2 m x 2.1 m
uncoated single-pane window is replaced with a double-glazed window with a
low-e coating and argon fill (a relatively common configuration for current win-
dows). The inside temperature is a constant 20°C, and the outside temperature is a
constant -5°C.
A 50-L electrical radiator containing heating oil is placed in a 50-m³ room. Both the room and the oil in the
radiator are initially at 5°C. The radiator with a rating of 3 kW is now turned on. At the same time, heat
is lost from the room at an average rate of 0.3 kJ/s. After some time, the average temperature is measured
to be 20°C for the air in the room, and 60°C for the oil in the radiator. Taking the density and the specific
heat of the oil to be 950kg/m³ and 2.2kJ/(kg °C), respectively, determine how long the heater is kept on.
Assume the room is well-sealed so that there are no air leaks.
1
Which of the following produces pure water day and night?
a.
Passive solar water still
b.
Solar dryer
c.
Forced circulation water heater
d.
Active solar water still
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- 1. An unknown lamp placed 6m from a photometer screen provides the same illuminance as a 90 cd lamp placed 4 m from the screen. What is the candlepower of the unknown lamp? 2. The illuminance of a room 20 ft x 15 ft is being designed. The illuminance required is 50 footcandles. What is the total required lumens output of the lamp assuming room and luminaire efficiency of 42%?arrow_forwardHeat power loss from a district heating line with two separate pipes: How big is the loss in W / m? Conditions: Outer pipe diameter of 100 mm, insulation thickness of 50 mm, thermal conductivity of insulation of 0.03 W / mK, ground thermal conductivity of 1.5 W / mK, distance of 1 m between pipe center and ground surface, distance of 0.6 m between pipe center, forward temperature of 80 °C, return temperature of 50°C, and ambient temperature of 5°C.arrow_forwardA mains fed 12000 litre tank supplies hot rinse water (45oC) for a food processing operation. Calculate the power of electric immersion heater(s) if the tank is fully replenished by 05:00 in the morning and the facility needs the hot water at 08:00.arrow_forward
- An insulated piston-cylinder device contains 4 L of saturated liquid water at a constant pressure of 200 kPa. Water is stirred by a paddle wheel while a current of 8A flows for 50 min through a resistor placed in the water. If one-half of the liquid is evaporated during this constant-pressure process and the paddle-wheel work amounts to 300 kJ, determine the voltage of the source. Also, show the process on a P-v diagram with respect to the saturation lines.arrow_forwardAn insulated steam pipe having outside diameter of 3 cm is to be covered with two layers of insulation each having a thickness of 2.5 cm. the thermal conductivity of one material is 5 times that of the other assuming that the steam pipe surface temperature and outer air temperature remain fixed . how much change in heat transfer take place if the better insulating material is next to the pipe than it is on outer side?arrow_forward2. A parallel-plate capacitor initially has a capacitance of 100 F. What will be the capacitance if the distance between the plates is doubled?arrow_forward
- A pump lifts 60°F water from a stream to a reservoir whose surface is an unknown distance above the free surface of the stream. The suction pipe (from the stream to the pump) is 250 ft of 8-in Schedule 40 steel pipe, while the discharge pipe (from the pump to the reservoir) is 2250 ft of 8-in Schedule 40 PVC (plastic) pipe. The pump consumes 150 hp and has an estimated efficiency of 85%. The suction inlet of the pump is located 2.5 ft below the surface of the stream, while the discharge port of the pump is located at the same elevation as the surface of the stream. A differential manometer connected to the suction and discharge sides of the pump measures a pressure difference of 128 psi. Consider the friction loss in the piping (using the Darcy-Weisbach equation), but neglect other (minor) losses. Flow Reservoir Pump 2.5 ft Streamarrow_forwardHow can a gas-fired warm-air furance be used to cool a building?arrow_forwardOne of the 250 fins of a baseboard heater is shown. Each fin has a2.5-centimeter hole in it.arrow_forward
- An electric baseboard heater has 25 ohms of resistance. The heater uses 9.6amperes of current. Find in volts the voltage required for the heater.arrow_forwardBlowers are used in wastewater treatment plants to assist microorganisms in degrading pollutants. The impeller of a centrifugal blower has a radius of 15 cm and a blade width of 6.1 cm at the inlet, and a radius of 30 cm and a blade width of 3.4 cm at the outlet. The blower delivers atmospheric air at 20°C and 95 kPa. Disregarding any losses and assuming the tangential components of air velocity at the inlet and the outlet to be equal to the impeller velocity at respective locations, determine the volumetric flow rate of air when the rotational speed of the shaft is 800 rpm and the power consumption of the blower is 120 W. Also determine the normal components of velocity at the inlet and outlet of the impeller.arrow_forwardH.WII Cooling Load Estimation An air conditioned room in the Basra city that measures 3 m wide, 3.5 m high and 6 m deep. The window size 1.5 m*1.5 m, mounted on the wall with no external shading and the door size 2m*1m. Calculate the sensible, latent and total heat gains on the room. What is the required cooling capacity? Assume all specification parameters that must be taken into account when calculating cooling load. 6 m 2 *1 m 3 m 1.5 * 1.5 m NW NE LNL E ESE SSW SSF SW SEarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you