Electronics Fundamentals: Circuits, Devices & Applications
8th Edition
ISBN: 9780135072950
Author: Thomas L. Floyd, David Buchla
Publisher: Prentice Hall
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 7, Problem 21P
A 20 cm long conductor is moving upward between the poles of a magnet as shown in Figure 7-53. The pole faces are 8.5 cm on each side and the flux is 1.24 mWb. The motion produces an induced voltage across the conductor of 44 mV. What is the speed of the conductor?
Expert Solution & Answer

Want to see the full answer?
Check out a sample textbook solution
Students have asked these similar questions
A dc compound motor having a rating of 10 kW,
1150 r/min, 230 V, 50 A, has the following losses at
full-load:
bearing friction loss
40 W
brush friction loss
==
50 W
windage loss
=
200 W
(1)
total mechanical losses
=
290 W
(2)
iron losses
=
420 W
(3)
copper loss in the shunt field
=
120 W
copper losses at full-load:
(4)
a. in the armature
b. in the series field
c. in the commutating winding
total copper loss in the
500 W
25 W
70 W
armature circuit at full-load
=
595 W
4 What determines the power rating of a ma-
chine?
-5 If we cover up the vents in a motor, its out-
put power must be reduced. Explain.
-6 If a motor operates in a cold environment,
may we load it above its rated power? Why?
An electric motor driving a skip hoist with-
draws 1.5 metric tons of minerals from a
trench 20 m deep every 30 seconds. If the
hoist has an overall efficiency of 94 percent,
calculate the power output of the motor in
horsepower and in kilowatts.
Chapter 7 Solutions
Electronics Fundamentals: Circuits, Devices & Applications
Ch. 7 - The tesla (T) and the gauss (G) are both units for...Ch. 7 - The unit for measuring magnetomotive force (mmf)...Ch. 7 - Ohm’s law for a magnetic circuit gives the...Ch. 7 - A solenoid is a form of electromagnetic switch...Ch. 7 - A hysteresis curve is a plot of flux density (B)...Ch. 7 - To produce an induced voltage in a coil, the...Ch. 7 - Prob. 7TFQCh. 7 - Prob. 8TFQCh. 7 - Prob. 9TFQCh. 7 - Prob. 10TFQ
Ch. 7 - Prob. 1STCh. 7 - Prob. 2STCh. 7 - Prob. 3STCh. 7 - Prob. 4STCh. 7 - Prob. 5STCh. 7 - Prob. 6STCh. 7 - Prob. 7STCh. 7 - The electromagnetic activation of a movable shaft...Ch. 7 - When there is current through a wire placed in a...Ch. 7 - Prob. 10STCh. 7 - Prob. 11STCh. 7 - Prob. 12STCh. 7 - Prob. 13STCh. 7 - Prob. 14STCh. 7 - Prob. 15STCh. 7 - The cross-sectional area of a magnetic field is...Ch. 7 - In a certain magnetic field the cross-sectional...Ch. 7 - Wha is the flux in a magnetic material when the...Ch. 7 - At a given location, the earth’s magnetic field...Ch. 7 - A very strong permanent magnet has a field of...Ch. 7 - Prob. 6PCh. 7 - What is the relative permeablility of a...Ch. 7 - Determine the reluctance of a material with a...Ch. 7 - What is the magnetomotive force in a 500 turn coil...Ch. 7 - Typically, when a solenoid is activated, is the...Ch. 7 - Prob. 11PCh. 7 - Explain the sequence of events in the circuit of...Ch. 7 - Prob. 13PCh. 7 - What is the magnetizing force in Problem 9 if the...Ch. 7 - How can the flux density in Figure 7-51 be changed...Ch. 7 - In Figure 7-51, determine the following if the...Ch. 7 - Determine from the hysteresis curves in Figure...Ch. 7 - According to Faraday’s law, what happens to the...Ch. 7 - The voltage induced across a certain coil is...Ch. 7 - Prob. 20PCh. 7 - A 20 cm long conductor is moving upward between...Ch. 7 - Prob. 22PCh. 7 - If a generator is 80% efficient and delivers 45 W...Ch. 7 - Prob. 24PCh. 7 - If the output voltage in Problem 24 is 14 V, what...Ch. 7 - Prob. 26PCh. 7 - Prob. 27PCh. 7 - A basic one-loop de generator is rotated at 60...Ch. 7 - Assume that another loop of wire. 90 from the...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The efficiency of a motor is always low when it operates at 10 percent of its nominal power rating. Explain.arrow_forwardA dc motor connected to a 240 V line pro- duces a mechanical output of 160 hp. Knowing that the losses are 12 kW, calculate the input power and the line current.arrow_forwardA 115 V dc generator delivers 120 A to a load. If the generator has an efficiency of 81 percent, calculate the mechanical power needed to drive it [hp].arrow_forward
- A machine having class B insulation attains a temperature of 208°C (by resistance) in a torrid ambient temperature of 180°C. a. What is the temperature rise? b. Is the machine running too hot and, if so, by how much?arrow_forward1 Name the losses in a dc motor. 2 What causes iron losses and how can they be reduced? -3 Explain why the temperature of a machine increases as the load increases.arrow_forward20. A tractor weighing 14 kN with a wheel base of 3m carries an 8 kN load on its rear wheel. Compute the maximum bending moment and shear when crossing a 4.5 span. Consider the load only at the wheels.arrow_forward
- A 110-V, three-phase, Y-connected, 8 pole, 48-slot, 6000-rpm, double-layer wound chronoun anı vonorotor boo 10 +1 urn or oilarrow_forward-7 Name some of the factors that contribute to the deterioration of organic insulators. -8 A motor is built with class H insulation. What maximum hot-spot temperature can it withstand?arrow_forwardCalculate the full-load current of a 250 hp, 230 V dc motor having an efficiency of 92 percent.arrow_forward
- Assignment #2 A 110-V, three-phase, Y-connected, 8 pole, 48-slot, 6000-rpm, double-layer wound, synchronous generator has 12 turns per coil. If one side of the coil is in slot 1, the other side is in slot 6. There are 4 parallel paths. When the generator delivers the rated load at a line voltage of 110 V, the voltage regulation is 5%. What is the flux per pole? Draw two consecutive phasegroups of one of the phase windings and connect them (a) in series and (b) in parallel showing the Start (S) and Finish (F) of both connections. (A separate drawing for each connection)arrow_forward3-4 Transmissiva Live of 120km has R= 0.2 ~2/15 X= 0.8 -2/km Y = 15H/6 5/km The line is supplies a load of 45 kV, SOMW, 0.8 lead p.f find sending voltage, Sending Current p.f. Sanding Voltage Regulation ⑨Voltage 5 Ⓒ charching coming! изу usy π cct लेarrow_forwardA (medium) single phase transmission line 100 km long has the following constants : Resistance/km = 0.25 Q; Susceptance/km = 14 × 10° siemen ; Reactance/km = 0.8 Receiving end line voltage = 66,000 V Assuming that the total capacitance of the line is localised at the receiving end alone, determine (i) the sending end current (ii) the sending end voltage (iii) regulation and (iv) supply power factor. The line is delivering 15,000 kW at 0.8 power factor Lead Draw the phasor diagram to illustrate your calculations.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning

Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
The Biot-Savart Law; Author: Jennifer Cash;https://www.youtube.com/watch?v=1BoIH6Quhiw;License: Standard Youtube License