Heating Ventilating and Air Conditioning: Analysis and Design
Heating Ventilating and Air Conditioning: Analysis and Design
6th Edition
ISBN: 9780471470151
Author: Faye C. McQuiston, Jeffrey D. Spitler, Jerald D. Parker
Publisher: Wiley, John & Sons, Incorporated
bartleby

Concept explainers

bartleby

Videos

Textbook Question
Book Icon
Chapter 4, Problem 4.28P

A maximum of 10 smokers are anticipated in a smong room and each is expected to contribute about 150 μ g / min of enironmental tobacco smoke (ETS) to the space. It is desired to hold the particulate level of ETS below 180 μ g / m 3 using filters ith an effective efficiency of 80 percent and an intake of outdoor air at the rate of 20 cfm per person. Assuming a ventilation effectiveness of 0.85 and the filter located downstream of the mixed recirculated and outdoor air, determine the required rate of supply air to the room.

Blurred answer
Students have asked these similar questions
What is the principle of operation of vapor absorption system? Why is ammonia water system common? Purpose of water in the ammonia absorption system Which energy does vapor absorption system uses? Piping material of vapor absorption system?
Calculate the EER rating of a 20 ton (240000 Btu) air conditioning unit with an average electrical load of 30 kW. An air conditioning plant supplies air to a room at a rate of 2.5 kg/s, the supply air being made up of equal parts by weight of outdoor and recirculated air. The mixed air passes through a cooler coil fitted with a by-pass duct, face and by pass dampers being used for humidity control. The air then passes through an after heater and supply fan. In a test on the plant, the following conditions (Table Qu 4) were recorded; 3 Table Qu. 4: Parameters recorded Relative humidity Dry bulb temperature °C Wet bulb temperature °C % Outdoor air 270 20.5 Room air 210 50 Supply air Air leaving cooler 160 11.8 80 90 coil Make neat sketches showing the plant arrangement and the psychrometric cycle and identify the corresponding points on both diagrams. Calculate the following; mass of air through the cooler coil load on cooler coil load on heater
A small-scale Compressed Air Energy Storage (CAES) system uses a rigid tank, whichhas been sized to 1m3. The air storage helps support various fluid power (pneumatics)requirements, but also serves for energy storage (when fully charged).The tank sits in a plant room having a temperature of 25oC at 1 atmosphere (101.325kPa).When delivered new and installed the tank (and the ambient air it contains) is assumedinitially at the same steady state conditions in the plant room. The tank can be filled with(dry) air to a maximum pressure of 300bar. When left in the plant room, the pressurised airtank eventually attains the plant room temperature.You may assume:> Steady state conditions apply> Negligible changes in kinetic and potential energy> Thermal mass of the tank (metal) is negligible Apply the ideal gas equation and calculate the mass of 25oC air (units: kg) in the fullypressurised tank.

Chapter 4 Solutions

Heating Ventilating and Air Conditioning: Analysis and Design

Additional Engineering Textbook Solutions

Find more solutions based on key concepts
Knowledge Booster
Background pattern image
Mechanical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Hydronics Step by Step; Author: Taco Comfort Solutions;https://www.youtube.com/watch?v=-XGNl9kppR8;License: Standard Youtube License