Understanding Motor Controls
4th Edition
ISBN: 9781337798686
Author: Stephen L. Herman
Publisher: Delmar Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 37, Problem 7RQ
To determine
The size of the conductor, overload size, fuse size, NEMA and IEC starter sizes, the upper and lower range of the starting current for the motor.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A balanced star-connected load of (8 + j6) Q per phase is connected to a Balanced 3- phase 400-V supply. Find the line current, power factor, power
Example 7-3.
A 460-V, 25-hp. 60-Hz, four-pole, Y-connected induction motor has
the following impedances in ohms per phase referred to the stator circuit:
- 0.641n
X,-1.106 N
R2 - 0.332 N
X2
= 0.464
XM - 26.3 N
The total rotational losses are 1100 W and are assumed to be constant. The core loss is
lumped in with the rotational losses. For a rotor slip of 2.2 percent at the rated voltage and
rated frequency, find the motor's
(a) Speed
(b) Stator current
(c) Povwer factor
(d) Peony and Pout
(e) Tiad and Toad
Efficiency
Q A motor of 15 horsepower, has a code letter L, and is operated on a 400-volt line. Find the locked rotor current
Chapter 37 Solutions
Understanding Motor Controls
Knowledge Booster
Similar questions
- A large motor has a full load current rating of 425 amperes. Current transformers with a ratio of 600:5 are used to reduce the current to the overload heaters. What should be the full load current rating of the overload heaters?arrow_forwardIf dual-element time delay fuses are to be used as the short circuit protective device, what size fuses should be used to protect the circuit in question #12? Five 5 HP, three-phase motors with NEMA code B are connected to a 240-volt line. The conductors are copper with type THWN insulation. What size conductor should be used to supply all of these motors?arrow_forwardAn inductor has an inductance of 0.025 H and a wire resistance of 3 Ω. How long will it take the current to reach its full Ohm’s law value?arrow_forward
- A 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardName three factors that determine the amount of induced voltage.arrow_forwardal Three coils each having resistance of 29 N are connected in star across 422 V, 50 Hz supply. Then the total power consumed is O 211.77 W O 3545.51 W O 730.95 W O 6140.83 Warrow_forward
- armature rotated at @ An 8- pole, lap wound 350 rpm is required to generate 260V. The useful Flud per pale is No of the armature Conductors. c.oS Wb, Calculate the totularrow_forwardAn 8 pole, lap connected armature has 500 conductors and its generated e.m.f is 120V. If the flux per pole is 20 mWb, then the speed of machine is,arrow_forwardQuestion 2 Beli vifth Slack side Motor (imprut) Tight side Beli thickpess\ Centre distance Figure 2 Figure 2 shows an open flat belt drive connected to a motor and a pulley. The motor transmits 20 kw to the connect pulley of 450 mm diameter and is rotating at 850 r/min to a second pulley rotating at 400 r/min. The distance between pulley centres is approximately 2 m. The belt is 6 mm thick and has a density of 970 kg/m. The maximum stress in the belt is not to exceed 2,7 MPa. The coefficient of friction for both pulleys is 0,3. Determine: 2.1. The diameter of the second pulley. 2.2. The length of the belt. 3.3. The width of the belt taking centrifugal tension into account.arrow_forward
- A 125-hp synchronous motor is connected to a 230-volt three-phase AC line. The motor is intended to operate at 80% power factor. What is the full-load running current of this motor? What are the minimum size NEMA and IEC starters that should be used to connect this motor to the line?arrow_forwardalso find the efficiency NPSHR Lastly, what is the motor power requirement referring to questionarrow_forwardEx: A single phase 50 KVA transformer has primary voltage of 6600 v and secondary voltage of 254 v and has 32 secondary turns. Calculate the number of primary turns and primary and secondary currents.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning