Understanding Motor Controls
4th Edition
ISBN: 9781337798686
Author: Stephen L. Herman
Publisher: Delmar Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 37, Problem 12RQ
To determine
The size of the conductor used to supply the motors.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Question 2
Beli vifth
Slack side
Motor
(imprut)
Tight side
Beli thickpess\
Centre distance
Figure 2
Figure 2 shows an open flat belt drive connected to a motor and a pulley. The
motor transmits 20 kw to the connect pulley of 450 mm diameter and is rotating
at 850 r/min to a second pulley rotating at 400 r/min. The distance between
pulley centres is approximately 2 m. The belt is 6 mm thick and has a density of
970 kg/m. The maximum stress in the belt is not to exceed 2,7 MPa. The
coefficient of friction for both pulleys is 0,3.
Determine:
2.1. The diameter of the second pulley.
2.2. The length of the belt.
3.3. The width of the belt taking centrifugal tension into account.
There is a 3 HP, 220 Vrms single - phase induction motor that operates with a 0.85
lagging power factor and 80 9% efficiency. What is the magnitude of the RMS motor
current?
O 75 Amps
15 Amps
O 5 Amps
O 3 Amps
Ex:
A single phase 50 KVA transformer has primary voltage of 6600 v and
secondary voltage of 254 v and has 32 secondary turns. Calculate the
number of primary turns and primary and secondary currents.
Chapter 37 Solutions
Understanding Motor Controls
Knowledge Booster
Similar questions
- Two transformers rated at 100 kVA each are connected in an open-delta connection. What is the total output power that can be supplied by this bank?arrow_forwardA large motor has a full load current rating of 425 amperes. Current transformers with a ratio of 600:5 are used to reduce the current to the overload heaters. What should be the full load current rating of the overload heaters?arrow_forwardA 480-volt three-phase load is rated at 34.5 kVA. It is to be supplied with variable three-phase voltage. Because the load is continuous, the transformers ratings are to be increased by 1.25% of the rated load. Three variable autotransformers are used to supply this load. Refer to Table 4-2 and determine the standard size of each transformer that should be used to make this connection.arrow_forward
- A 10 kVA transformer has a primary voltage rating of 240 volts and a secondary voltage rating of 480 volts. The transformer is connected to a circuit protected by a 100 ampere circuit breaker. The secondary is protected by a 25-ampere fuse. Does the primary require separate overcurrent protection?arrow_forwardAn AC power source is connected across 325 turns of an autotransformer, and the load is connected across 260 turns. What is the turns ratio of this transformer?arrow_forwardA 125-hp synchronous motor is connected to a 230-volt three-phase AC line. The motor is intended to operate at 80% power factor. What is the full-load running current of this motor? What are the minimum size NEMA and IEC starters that should be used to connect this motor to the line?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Understanding Motor ControlsMechanical EngineeringISBN:9781337798686Author:Stephen L. HermanPublisher:Delmar Cengage LearningElectrical Transformers and Rotating MachinesMechanical EngineeringISBN:9781305494817Author:Stephen L. HermanPublisher:Cengage Learning
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Electrical Transformers and Rotating Machines
Mechanical Engineering
ISBN:9781305494817
Author:Stephen L. Herman
Publisher:Cengage Learning