Question
Chapter 22.2, Problem 10R
To determine
Mention the length of the cable required for wiring of the attic exhaust fan circuit.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
QUESTION 3
We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.
QUESTION 8
We are running 3 wires in an IMC to a control panel with a 150 amp circuit breaker disconnect in the control panel. The conduit is run 12 inches above the roof on a strut rack. The ambient air temperature is 88 degrees. This control panel feeds the #1 cooling fan. What sized ungrounded conductors do we need? All conductors have typeTHHN insulation.
Follow the procedures in troubleshooting the defects and faults of an electric fan by filling in the missing steps.Doesn't rotate 1.___________ 2.____________ Check for Open AC cord or wiring3. ___________4.___________ Defective switch/electronic system control 5. _____________Defective module (system control).
Chapter 22 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 22.1 - Prob. 1RCh. 22.1 - Prob. 2RCh. 22.1 - Prob. 3RCh. 22.1 - Prob. 4RCh. 22.1 - Prob. 5RCh. 22.1 - Prob. 6RCh. 22.1 - Prob. 7RCh. 22.1 - Prob. 8RCh. 22.1 - Prob. 9RCh. 22.1 - Prob. 10R
Ch. 22.1 - Prob. 11RCh. 22.1 - Prob. 12RCh. 22.2 - Prob. 1RCh. 22.2 - Prob. 2RCh. 22.2 - Prob. 3RCh. 22.2 - Prob. 4RCh. 22.2 - Prob. 5RCh. 22.2 - Prob. 6RCh. 22.2 - Prob. 7RCh. 22.2 - Prob. 8RCh. 22.2 - Prob. 9RCh. 22.2 - Prob. 10RCh. 22.2 - Prob. 11RCh. 22.2 - Prob. 12RCh. 22.3 - Prob. 1RCh. 22.3 - Which of the following statements Meets Code?...Ch. 22.3 - Prob. 3RCh. 22.3 - Prob. 4RCh. 22.3 - Prob. 5RCh. 22.3 - Prob. 6RCh. 22.3 - Prob. 7RCh. 22.3 - Prob. 8R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Grounding Lighting Fixtures. There are specific requirements for grounding lighting fixtures. How must they be grounded and with what size conductors? Be sure and cite the code in your answers.arrow_forwardEquipment Grounding 13. A metal elbow is a part of a nonmetallic, underground raceway. The elbow won't need to be grounded as long as it's encased in at least _______ inches of concrete. A. 4 B. 5 C. 2 D. 6 13 A. Which of the following can be in the form of a wire and is required to be installed with feeders and branch circuits? A. Phased neutral conductorB. Equipment grounding conductor C. Grounded neutral conductorD. Grounding electrode conductorarrow_forward1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. Solararrow_forward
- a.2. Which of the following statements about grounding electrode conductors is true?A. They restrict the ground connection.B. They eliminate potential differences between conductive objects and the Earth electrode.C. They facilitate operation of overcurrent protective devices.D. They perform bonding between the Earth and grounded conductors.a.3. Main bonding jumpers are required to be made of _______ or other corrosion-resistant material.A. brassB. aluminumC. copperD. copper-clad aluminumarrow_forwardof p o How many conductors enter the ceiling fan/light wall box? Switch ond out let boxes s tirst 10. What type and size of box may be used for the ceiling fan/light wall box?. 11. What type of covers are used with 4 in. square outlet boxes? 12. a. Does the circuit for the Master Bedroom have a grounded circuit conductor? b. Does it have an equipment grounding conductor? c. Explain the difference between a "grounded" conductor and an "equipment grounding" conductor. 13. Approximately how many feet (meters) of 2-wire cable and 3-wire cable are needed to ft complete the circuit supplying the Master Bedroom? Two-wire cable: ft (- m). m). Three-wire cable: 14. If the cable is laid in notches in the corner studs, what protection for the cable must be provided? 15. How high are the receptacles mounted above the finished floor in this bedroom? 16. Approximately how far from the bedroom door is the first receptacle mounted? (See the plans.) 17. What is the distance from the finished floor to…arrow_forward14. A grounded circuit conductor and the equipment grounding conductor should always be joined at theservice by aA. steel raceway.B. main bonding jumper.C. bus bar.D. short length of aluminum conductor.arrow_forward
- To testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___. A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnectedarrow_forward7.A. Ferrous metal raceways or enclosures are made with _______ content.A. steel or brassB. aluminum or ironC. brass or aluminumD. iron or steel7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.arrow_forwardPractically it is possible the _______________ cables pass through on poles along with high voltage power cables.arrow_forward
- 16. The primary purposes of insulation shielding are to confine voltage stresses to the ?, dissipate insulation leakage current, drain off capacitive current, and carry ground fault current to facilitate operation of the ground- fault protective devices. Oa. cable outer sheath Ob. circuit Oc. conductor Od. insulationarrow_forwardThe recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwardAssume a bank of heating strips is rated at 22 KW and is connected to 240 volts. The heat strips operate for 4 hours at a time and are located in an area with an ambient temperature of 86 degrees F. The termination temperature rating of the heat disconnect lugs are unknown. Copper conductors with type THWN-2 insulation are to be used because of the environment of the installation to connect the heaters. What size conductors should be used?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License