To testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___.
A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnected
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Low-voltage conductors. a. are not powerful enough to cause death from electrocution b. must exceed 480V to cause death C. are responsible for most electrocution deaths due to the frequency of contact d. are unlikely to cause injury if rubber-soled shoes are wornarrow_forwardGrounding lighting fixtures. Threre are specific requirements for grounding lighting fixtures. How must they be grounded and with what size conductors?arrow_forwardQ.3. Give two reasons for overloading and two reasons for short circuit and two precautions to prevent each.arrow_forward
- How does the skin effect phenomenon affect the performance of copper cables?arrow_forwardHow can lighting fixture be ground and what size of the conductor can be usedarrow_forwardConductors of dissimilar metals shall not be intermixed in a terminal or splicing connector.Please explain me why.arrow_forward
- If the NEC provides a requirement to grounding equipment, it generally implies that there will be a direct connection to Earth of connection through a/an A. Equipment grounding conductor B. Bonding conductor C. Grounding electrode conductor D. Equipotential bonding conductorarrow_forward1-Calculate the minimum and maximum protection for an A/C , its conductors(75 ºC) and its grounding. For the following values:1- FLC compressor = 30 A2- FLC condenser = 3 Aarrow_forwardExplain the differences in protection between the thermal and magnetic components in a magnetic circuit breakerarrow_forward
- What size conductor should be used in a 2-wire system to service a load of 6,500 watts, 150 feet from the generator? The voltage at the load is 120 volts, and the voltage drop should not exceed 2.5 volts. Round to a whole number. value of K for copper is 10.8arrow_forwardb. 63 rule where two different temperatures are encountered for the same conductors 38. An exception to the permits the application of the higher ampacity (lower temperature) if the length of the conductors that enter a higher temperature is not more than 10 ft (3.0 m) or not more than 10% of the total circuit length. C. ampacity rating d. flux rating a. circuit derating b. ampacity derating lood isarrow_forwardHow is the grounded dc conductor of a photovoltaic system required to be identified? a. shall be identified at the time of installation by distintive red markings on some of the terminations b. shall be identified at the time of installation by distintive blue marking at all terminations c. shall be identified at the time of installation by a distintive grouping of wires AWG #2 d. shall be identified at the time of installation by distinctive white marking at all terminations.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,