Interpretation:The mechanism of the production of an LMM Auger electron has to be explained.
Concept Introduction:The electrons which fallfrom the high energy level in an inner vacant shell. These emitted electrons are called auger electrons. This process takes place by the bombardment of atom with a electron having high energy.
Explanation of Solution
The electrons that areemitted from high energy level to the low energy level are called auger electrons.
The mechanism of the production of an LMM Auger electron consists of the formation of an ion which is excited electronically. The ion is excited after the removal of an electron from the
Want to see more full solutions like this?
- 5. (a) The Mossbauer effect depends upon the recoilless emission of a y-ray. How important is it to embed the emitter nucleus in a bulky and rigid crystal lattice? (b) Briefly describe the isomer shift in Mossbauer spectroscopy.arrow_forwardClassify the 19F nuclei in SF5− (which is square-pyramidal) into chemically or magnetically equivalent groups. Give your reasoning.arrow_forwardExplain (with the aid of one or more equations) why a LOWER selectivity coefficient for an interfering ion means an ISE is actually MORE selective for the target ion.arrow_forward
- The biuret reaction is a general method for the determination of proteins or peptides. This method is based on the reaction of the Cu2+ with four NH groups of the peptide bonds, forming a violet complex with an absorption maximum at 540 nm. The intensity of the color is proportional to the number of peptide bonds present, and therefore to the amount of protein. This reaction is specific, the dipeptides and amino acids give a negative reaction, and few substances interfere. A quantity of 19.89 g of fish meat is extracted with 100 mL of glacial acetic acid. Subsequently, 3 mL of the previous solution with 3 mL of the biuret reagent to generate the reaction, after 30 minutes. To reduce errors due to other interfering substances and residual turbidity, the corrected absorbance method Ac is applied to 500 nm and 570 nm. In a study, a standard sample analyzed by the Kjeldahl method (total Nitrogen analysis) is obtained, resulting in 0.43% N (w / v), (Protein content [%] =% N x 6.38). 3 mL of…arrow_forwardExplain how carbon is detected qualitatively.arrow_forwardCalculate the mass energy absorption coefficient for molybdenum for 2 Mev photons considering the radiative fraction is 28% and the K- binding energy for molybdenum is 20 kev.arrow_forward
- The speed of the electron immediately after the collision is 9.90 * 10 ^ 6 m / s. What should be the angle between the propagation direction of the event and the scattering protons?arrow_forward(c) Comment on the truth, or otherwise, of the following statement. "Fast time-scale flash photolysis can be used to determine rate constants for collisional relaxation (quenching) processes of singlet and triplet states. Radiative decay rate constants (Einstein A coefficients) can be determined from such measurements, and can also be calculated from absorption coefficients."arrow_forwardThe molar absorption coefficient of a substance dissolved in water is known to be 855 dm3mol-1cm-1 at 270 nm. To determine the rate of decomposition of this substance, a solution with a concentration of 3.25 mmol dm-3 was prepared. Calculate the percentage reduction in intensity when light of that wavelength passes through 2.5 mm of this solution. Ans: 1.6%arrow_forward
- The IR frequency of C≡N¯ in fac-[IrCl3(C≡N)3] is 2200 cm-1. Estimate the IR frequency of C≡N¯ for fac-[IrF3(C≡N)3] with an explanation.arrow_forwardAn aqueous solution of a triphosphate derivative of molar mass 502 g mol-1, was prepared by dissolving 17.2 mg in enough water to make 500 cm3 of solution and a sample was transferred to a cell of length 1.00 em. The absorbance was measured as 1.011. Calculate (a) the molar absorption coefficient;(b) the transmittance. expressed as a percentage.for a solution of twice the concentration.arrow_forwardQ.55 In 2 N H2SO4, an organic compound shows fluorescence with quantum yield, or = 0.42 and fluorescence rate constant, k= 5.25 × 107 s-'. The observed fluorescence life time of it under the same conditions (correct to 1 decimal place) is ns.arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningMacroscale and Microscale Organic ExperimentsChemistryISBN:9781305577190Author:Kenneth L. Williamson, Katherine M. MastersPublisher:Brooks ColePrinciples of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning