Concept explainers
(a)
Interpretation:
The factors related to the analyte influencing the emission intensity needs to be identified.
Concept introduction:
X-Ray photoelectron spectroscopy or XPS is a quantitative spectroscopic technique that is surface-sensitive. It measures the composition of materials with respect to elements in the range of parts per thousand. It also helps in determining the empirical formula, chemical state and electronic state of elements present in the materials.
It is now widely used because with the help of this technique not only the element within the films, but the other elements bonded to it can be determined.
For example, with the help of XPS technique, the oxidation state of metal in the metal oxide can be determined.
Explanation of Solution
The equation relating the intensity of emission and atomic concentration (density) is represented as follows:
Here,
In spectroscopy, the analyte is the molecule for which the concentration needs to be measured using spectroscopic techniques. In the above formula, the factors related to analyte are
(b)
Interpretation:
The factors related to the spectrometer influencing the emission intensity needs to be identified.
Concept introduction:
X-Ray photoelectron spectroscopy or XPS is a quantitative spectroscopic technique that is surface-sensitive. It measures the composition of materials with respect to elements in the range of parts per thousand. It also helps in determining the empirical formula, chemical state and electronic state of elements present in the materials.
It is now widely used because with the help of this technique not only the element within the films, but the other elements bonded to it can be determined.
For example, with the help of XPS technique, the oxidation state of metal in the metal oxide can be determined.
Explanation of Solution
The equation relating the intensity of emission and atomic concentration (density) is represented as follows:
Here,
Now, the factors influencing the emission intensity related to the spectrometer or instrument are
(c)
Interpretation:
The relation between the ratio of measured quantity in XPS for analyte to the internal standard and their atomic concentrations needs to be determined.
Concept introduction:
X-Ray photoelectron spectroscopy or XPS is a quantitative spectroscopic technique that is surface-sensitive. It measures the composition of materials with respect to elements in the range of parts per thousand. It also helps in determining the empirical formula, chemical state and electronic state of elements present in the materials.
It is now widely used because with the help of this technique not only the element within the films, but the other elements bonded to it can be determined.
For example, with the help of XPS technique, the oxidation state of metal in the metal oxide can be determined.
Explanation of Solution
In the quantitative XPS, the measured quantity is usually I/S. Here, I is the peak area and S is the sensitivity factor. For the analyte, the quantity measured is
The internal standard is the concentration of a substance present in every sample needed to be analyzed.
The ratio I/S is directly proportional to the concentration on the surface.
Or,
Similarly,
Thus, the relation between the ratio
(d)
Interpretation:
The given equation for the fractional atomic concentration of element A needs to be proved.
Concept introduction:
X-Ray photoelectron spectroscopy or XPS is a quantitative spectroscopic technique that is surface-sensitive. It measures the composition of materials with respect to elements in the range of parts per thousand. It also helps in determining the empirical formula, chemical state and electronic state of elements present in the materials.
It is now widely used because with the help of this technique not only the element within the films, but the other elements bonded to it can be determined.
For example, with the help of XPS technique, the oxidation state of metal in the metal oxide can be determined.
Explanation of Solution
The atomic concentration for an element (say 1) measured by XPS technique can be represented as
If the total number of elements is n, the fractional atomic concentration can be represented as follows:
Or,
Thus, for all the elements measured by XPS technique, the fractional atomic concentration for element A can be represented as follows:
Here,
(e)
Interpretation:
The atomic concentration of three elements that is C, N and O in the polyurethane sample needs to be determined.
Concept introduction:
In the quantitative XPS, the measured quantity is usually I/S.
Here, I is the peak area and S is the sensitivity factor. For the analyte, the quantity measured is
The internal standard is the concentration of a substance present in every sample needed to be analyzed.
The ratio I/S is directly proportional to the concentration on the surface.
Or,
Similarly,
Explanation of Solution
The given sample is polyurethane containing C, N and O elements that need to be detected by XPS.
The sensitivity factor for C, N and O is 0.25, 0.42 and 0.66 respectively.
Also, the peak area for C, N and O is 26550, 4475 and 13222 respectively.
The value of the atomic concentration of C, N and O can be calculated as follows:
Putting the values,
Similarly,
And,
Now, the value of the fractional atomic concentration of C can be calculated as follows:
Putting all the values,
Similarly, for N and O the atomic concentration can be calculated as follows:
And,
Putting the values,
Thus, the fractional percentage concentration of C, N and O will be:
Or,
Or,
(f)
Interpretation:
The limitations of quantitative analysis with XPS needs to be explained. The reason for atomic concentration measured to not correspond to the bulk composition needs to be explained.
Concept introduction:
X-Ray photoelectron spectroscopy or XPS is a quantitative spectroscopic technique that is surface-sensitive. It measures the composition of materials with respect to elements in the range of parts per thousand. It also helps in determining the empirical formula, chemical state and electronic state of elements present in the materials.
It is now widely used because with the help of this technique not only the element within the films, but the other elements bonded to it can be determined.
For example, with the help of XPS technique, the oxidation state of metal in the metal oxide can be determined.
Explanation of Solution
The limitation of quantitative analysis with XPS is as follows:
XPS is a surface technique, thus, it provides a limited amount of the organic information i.e. it is limited to elements with
The reason for the atomic concentrations measured not corresponding to the bulk composition is as follows: -
XPS can determine the quantity of elements present within the top 1-12 nm of the surface of the sample. XPS can only detect those electrons which get escaped from the sample and reach the detector for that photoelectron must travel through the sample. As depth increases, the signal detected from analytes at the surface is much stronger than the signals detected deeper to the surface of the sample.
(g)
Interpretation:
The percentage error in the atomic concentration of C, N and O needs to be determined.
Concept introduction:
For all the elements measured by XPS technique, the fractional atomic concentration for element A can be represented as follows:
Here,
The atomic concentration of C, N and O for the polyurethane sample is given 76%, 8.0% and 16% respectively.
The percentage error from the values calculated in part (e) can be calculated as follows:
Thus, the percentage error in the atomic concentration of C, N and O is 1%, 0.22% and 1.4% respectively.
Explanation of Solution
The atomic concentration of C, N and O for the polyurethane sample is given 76%, 8.0% and 16% respectively.
The percentage error from the values calculated in part (e) can be calculated as follows:
Thus, the percentage error in the atomic concentration of C, N and O is 1%, 0.22% and 1.4% respectively.
Want to see more full solutions like this?
- Regioselectivity Two potential products can form in the following E2 elimination promoted by KOtBu. Circle the major alkene product. KOtBu H3C H3C Indicate if the reaction in (d) is under kinetic control or thermodynamic control. (write or circle kinetic or thermodynamic control) 5arrow_forwardMetallic molybdenum can be produced from the mineral molybednite, MoS. The mineral is first oxidized in air to molybdenum trioxide and sulfur dioxide. Molybdenum trioxide is then reduced to metallic molybdenum using hydrogen gas and yielding water as the other product. Calculate the volumes of air and He at 17°C and 1.00 atm that are necessary to produce 1.00 x 103 kg of pure Mo from MoSz. Assume that air contains 21% oxygen by volume and also assume that both the oxidation and reduction reactions are quantitative.arrow_forwardDraw the major substitution product formed for this reactionarrow_forward
- Don't used Ai solutionarrow_forwardWhich of the following buffers is higher in buffer capacity? O a 1-L phosphate buffer containing 0.2 M of H2PO4 and 0.02 M of HPO² O a 1-L phosphate buffer containing 0.01 M of H2PO4 and 0.01 M of HPO² O a 1-L phosphate buffer containing 0.1 M of H2PO4 and 0.1 M of HPO O a 1-L phosphate buffer containing 0.1 M of H2PO4 and 0.01 M of HPOarrow_forwardAs some of you may know, I am an aficionado of Starbuck's Steamed Milk, Venti size. Steamed milk is made by passing superheated steam into a stainless steel container containing the milk. Assume that the steam is at 125°C, Lyap = 540 calories/gram, and the specific heat of steam is 0.500 calories/gram/degree C. Also assume that the milk is at 5°C and that 750 ml of milk represent the Venti size. The stainless steel container can be considered to have a mass of 400. grams and a specific heat capacity of 0.600 J/gram/K. If the density of milk is 1.00 grams/ml and its specific heat is 4.184 J/gram/K, how many grams of steam does it take to raise the milk's temperature to a comfortable 55°C? 1 Calorie = 4.184 Joules.arrow_forward
- A chemist weighed out 5.14 gm of a mixture containing unknown amounts of BaO (s) and CaO(s) and placed the sample in a 1.50 liter flask containing COz(g) at 30.0°C and 750 torr. After the reaction to form BaCOs(s) and CaCO:(s) was completed, the pressure of COz(g) remaining was 230 torr. Calculate the mass percentages of CaO(s) and BaO(s) in the sample.arrow_forwardDon't used Ai solutionarrow_forward4. Calculate At for the reaction, NHI) + 02(g) - N2(g) + 2H0(I), from the following data: 2NH.(g) = 3N20(g) - 4N2(g) + 3H20 (I) ДН = - 1010 KJ N20(g) = 3H(g) -> NzH4(1) + H,0(I) AH = -317 KJ 2NHs(g0 + 1/202(g) - AH = - 143 KJ H2(g) + 1/202(g) > H2O(I) AH = -286 KJarrow_forward
- 6 The volume of a sample of pure HCl gas was 189 ml at 25°C and 108 torr. It was completely dissolved in about 60 ml of water and titrated with a NaOH solution; 15.7 ml of the NaOH solution were required to neutralize the HCl. Calculate the molarity of the NaOH solution.arrow_forward7. In the reaction, Sn + HNO3 > Sn(NO.) + N20 + H,0, 1.050 grams of water was formed. How many grams of Sn reacted? How many ml of N20 were formed at 37°C and 747 mm Hg, if the gas was collected over water. The vapor pressure of water is 0.476 kPa.arrow_forward0.5000 moles of steam at 200°C was chilled in a ultra-low temperature freezer to -90°C. If the heat of vaporization of steam is 540. cal/gram, the heat of fusion of water is 80.0 cal/gram, the specific heat of steam is 0.500 cal/gram-°C, the specific heat of water is 1.000 cal/gram-°C, and the specific heat of ice is 0.500 cal/gram-°C, how many kJ of energy is released, assuming no energy loss to the environment? 1 calorie = 4.184 Joules.arrow_forward
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning