The three-phase source line-to-neutral voltages are given by
Is the source balanced?
(a) Yes
(b) No
Trending nowThis is a popular solution!
Chapter 2 Solutions
MindTap Engineering for Glover/Overbye/Sarma's Power System Analysis and Design, 6th Edition, [Instant Access], 1 term (6 months)
- Four conductors meet at a junction. the current are i1= 5sinwt, i2= 3sin(wt + 90) and i3= 2sin(wt-90). calculate the rms value of i4.arrow_forwardTwo power system areas operating at a nominal frequency of 60 Hz are connected with a tie line, and have the following characteristics: Area 1: R1 = 0.02 pu and D1 = 1 pu on a base of 1200 MVA Area 2: R2 = 0.03 pu and D2 = 0.8 pu on a base of 700 MVA The power flow direction on the tie line is from Area 1 to Area 2. Using a common base of 1000 MVA, what is the change in tie flow (in MW) for a load increase of 200 MW in Area 1? Select one: a.-56.16 MW O b. None of these O c.-143.84 MW O d.-38.02 MW <arrow_forwardTwo power system areas operating at a nominal frequency of 60 Hz are connected with a tie line, and have the following characteristics: Area 1: R1 = 0.01 pu and D1 = 0.8 pu on a base of 1200 MVA Area 2: R2 = 0.02 pu and D2 = 1 pu on a base of 600 MVA The power flow direction on the tie line is from Area 1 to Area 2. Using a common base of 1000 MVA, what is the change in prime mover power (in MW) in Area 2 (APmech2) for a load increase of 125 MW in Area 1?arrow_forward
- Two power system areas operating at a nominal frequency of 60 Hz are connected with a tie line, and have the following characteristics: Area 1: R1 = 0.01 pu and D1 = 0.8 pu on a base of 1200 MVA Area 2: R2 = 0.02 pu and D2 = 1 pu on a base of 600 MVA The power flow direction on the tie line is from Area 1 to Area 2. Using a common base of 1000 MVA, what is the change in prime mover power (in MW) in Area 2 (APmech2) for a load increase of 125 MW in Area 1? Select one: O a. 51.67 MW O b. None of these c. 24.74 MW O d.204.24 MWarrow_forwardFor the circuit given in Figure 1, a) Find the Thevenin equivalent circuit with respect to terminals a-b b) When a 5000 resistor is connected to terminal a-b, find the voltage on the resistor wwwwwwmm c) It will be connected to a-b terminals and its voltage on 5000 load will be 132 kV rms. What should be the capacitive reactance value that will increase it? wwwwwwwww d) What happens to the short-circuit current when the a-b terminals are short-circuited? 2+1202 000 m da 127/6 kV rms ob 1.5 +/902 000 w 12725 kV msarrow_forwardA single-phase source has a terminal voltage V=1200volts and a currentI=1530, which leaves the positive terminal of the source. Determine the real and reactive power and state whether the source is delivering or absorbing each.arrow_forward
- In a balanced system, the phasor sum of the line-to-line voltages and the phasor sum of the line-to-neutral voltages are always equal to zero. (a) False (b) Truearrow_forwardThree single-phase transformers, each rated 10MVA,66.4/12.5kV,60Hz, with an equivalent series reactance of 0.1 per unit divided equally between primary and secondary, are connected in a three-phase bank. The high-voltage windings are V-connected and their terminals are directly connected to a 115-kV three-phase bus. The secondary terminals are all shorted together. Find the currents entering the high-voltage terminals and leaving the low-voltage terminals if the low-voltage windings are (a) Y-connected and (b) - connected.arrow_forwardDoes an open- operation, the kVA rating compared to that of the original thr-phase bank is (a) 2/3 (b) 58 (c) 1arrow_forward
- A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and L=40mH. (a) Determine the power factor of the circuit and state whether it is lagging or leading. (b) Determine the real and reactive power absorbed by the load. (c) Calculate the peak magnetic energy Wint stored in the inductor by using the expression Wint=L(Irms)2 and check whether the reactive power Q=Wint is satisfied. (Note: The instantaneous magnetic energy storage fluctuates between zero and the peak energy. This energy must be sent twice each cycle to the load from the source by means of reactive power flows.)arrow_forwardX₂=0.1 1 XL +03 Soto X₁ = 0.2 X = 0.1 X = 0.1 Above is the one-line diagram of a simple power system. Each generator is represented by an emf behind the subtransient reactance. All impedances are expressed in per unit on a common base. All resistances and shunt capacitance are neglected. The generators are operating on no load at their rated voltage with their emfs in phase. A symmetrical fault occurs at bus 1 through a fault impedance Z, =j0.08 per unit. a) Using Thevenin's Theorem, determine the impedance to the point of fault and the fault current in per unit. b) Find the bus voltages and line currents during the fault. 2 O otoarrow_forwarda) why is there a wattmeter reading when the load is purely inductiveb) why is there no wattmeter reading when the load is purely capacitivearrow_forward