Chapter 19.2, Problem 5R
An 80-gallon electric water heater is energized for the first time. Approximately how many hours would it take to raise the water temperature 80°F (26.67°C) (from 40°F to 120°F [4.44°C to 48.89°C])? The water heater has a 3000-watt heating element.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.
A
#6 AWG
B
600 Kcmil
C
#8 AWG
D
#2 AWG
What size RMC do we need?
A
3"
B
3/4"
C
1"
D
1 1/2"
Please answer the following questions
Describe how solar chimney power plant operates. Give into details how solar water heater and solar oven operate
Please answer all the questions
A computer's power supply converts mains AC to low-voltage regulated DC power for the internal components of a computer. You are building a new computer. You are deciding which type of power supply to install.
Which of the following definitions BEST describes a valid type of power supply?
Correct Answer:
A single-rail power supply provides one rail (PCB trace). This provides the best safety for the computer by providing a single point of shutdown in the event of a short circuit.
Correct Answer:
A single-rail power supply provides one rail (PCB trace) used to always provide equal wattage to all devices attached to the power supply.
Correct Answer:
A dual-rail power supply provides separate rails (PCB traces) used to provide equal wattage to the devices attached to each rail.
Correct Answer:
A dual-rail power supply provides separate rails (PCB traces) used to balance the power load between multiple circuits, which prevents any one circuit from becoming overloaded.
Chapter 19 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 19.1 - Does a jet pump have any electrical moving parts...Ch. 19.1 - Prob. 2RCh. 19.1 - Where is the jet of the pump located?...Ch. 19.1 - Prob. 4RCh. 19.1 - Prob. 5RCh. 19.1 - Prob. 6RCh. 19.1 - Prob. 7RCh. 19.1 - What is compressed in the water storage tank?...Ch. 19.1 - Explain the difference between a 2-wire...Ch. 19.1 - Prob. 10R
Ch. 19.1 - Why is a 240-volt motor preferable to a 120-volt...Ch. 19.1 - How many amperes does a 1-horsepower, 240-volt,...Ch. 19.1 - What size are the conductors used for this branch...Ch. 19.1 - Prob. 14RCh. 19.1 - What provides the running overload protection for...Ch. 19.1 - What is the maximum ampere setting permitted for...Ch. 19.1 - Prob. 17RCh. 19.1 - Because the controller contains the motor starting...Ch. 19.1 - Prob. 19RCh. 19.1 - Proper pressure of the submersible pump system is...Ch. 19.1 - Fill in the data for a 16-ampere electric motor,...Ch. 19.1 - The NEC is very specific in its requirement that...Ch. 19.1 - Does the NEC allow submersible pump cable to be...Ch. 19.1 - Must the disconnect switch for a submersible pump...Ch. 19.1 - A metal well casing (shall) (shall not) be bonded...Ch. 19.2 - Prob. 1RCh. 19.2 - A major hazard involved with water heaters is that...Ch. 19.2 - Prob. 3RCh. 19.2 - The heating elements in electric water heaters are...Ch. 19.2 - An 80-gallon electric water heater is energized...Ch. 19.2 - Prob. 6RCh. 19.2 - For residential water heaters, the Consumer...Ch. 19.2 - An 80-gallon electric water heater has 60F...Ch. 19.2 - Approximately how long would it take to produce...Ch. 19.2 - Two thermostats are generally used in an electric...Ch. 19.2 - a. How many heating elements are provided in the...Ch. 19.2 - When does the lower heating element operate?...Ch. 19.2 - Prob. 14RCh. 19.2 - Prob. 15RCh. 19.2 - Prob. 16RCh. 19.2 - a. If both elements of the water heater in this...Ch. 19.2 - a. How much power in watts would the two elements...Ch. 19.2 - A condominium owner complains of not getting...Ch. 19.2 - For a single, nonmotor-operated electrical...Ch. 19.2 - A 7000-watt resistance-type heating appliance is...Ch. 19.2 - Prob. 22R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. If both elements of the water heater in this residence are energized at the same time, how much current will they draw? (Assume the elements are rated at 240 volts.) b. What size and Type THHN wire is required for the load of both elements? Show calculations.arrow_forwardHousehold refrigerators have arrays or coils of tubing on the outside, usually at the back or bottom. When the refrigerator is running, the tubing becomes quite hot. Where does the heat come from?arrow_forwardAssume that you were tasked to install a microwave oven using 12 AWG copper. When you look at the spec plate for the oven, you discover that the oven is rated for 240V, 60HZ, and takes a current of 25A. The location for the oven is 785.7 Ft, away from the breaker panel. Calculate the expected VD if any. Assume temperature to be 75 ̊ C what is the answer? VD?arrow_forward
- A thermal power station has a boiler efficiency of 85 % and turbine efficiency of 90 %. The thermal efficiency of the station is?arrow_forwardA building load consists of fifty 60 – watt, twenty 90 – watt and fifteen 55 – watt incandescentlamps all connected in parallel to a110 – volt source. Calculate: (a) the current through eachlamp, (b) resistance of each lamp, (c) total power and (d) total current. ILLUSTRATE ALSO THE CIRCUIT DIAGRAM.arrow_forwardIn oil emerged kva is there any piping and instrumentation diagram provided by the manufacturer. Can you explain me if needed or not.arrow_forward
- We are running 3 wires in an IMC to a control panel with a 150 amp circuit breaker disconnect in the control panel. The conduit is run 12 inches above the roof on a strut rack. The ambient air temperature is 88 degrees. This control panel feeds the #1 cooling fan. What sized ungrounded conductors do we need? All conductors have typeTHHN insulation. A #1 AWG B 100 Kcmil C #1/0 AWG D #10 AWG What sized IMC do we need? A 3/4" B 1 1/4" C 1" D 1 1/2"arrow_forward(Diagram+Explanation. (i) Horizontal Straight Tube Boiler for thermal power plant. (ii) Cyclone Fired Boiler for thermal power plantarrow_forwardQUESTION 5 We would like to run the power wires for both cooling pumps in the same RMC from the Breaker panel to a junction box above the control panel. What size ungrounded conductors do we need for the 100 amp load? All conductors have typeTHHN insulation. A #6 AWG B #3 AWG C #4 AWG D #1 AWGarrow_forward
- You are a journeyman electrician in an industrial plant. You have been assigned the task of connecting a 25-kW electric heater to a 240-V, single-phase panel. The heater is located in an area with an ambient temperature of 90°F. The conductors are to be copper with Type TW insulation. The heater is expected to operate for more than three hours at a time. What size conductors would you use to connect this heater? Is this correct? I=P/EI=25000 W/ 240 VI= 104.17 amps x 125%I= 130.21 amp/ .96I= 135.63 amp2/0 AWG conductor will be neededarrow_forwardbuilding load consists of fifty 60 – watt, twenty 90 – watt and fifteen 55 – watt incandescent lamps all connected in parallel to a110 – volt source. Calculate: (a) the current through each lamp, (b) resistance of each lamp, (c) total power and (d) total current.arrow_forward2. A facility manager replaces all the TS lights in an office when they have reached 80% of their rated life of 20,000 hours. The lights operate for 12 hours each day, 5 days per week for 52 weeks of the year. What is the group re-lamping interval for these lights? a. 3.7 years b. 4.6 years c. 5.1 years d. 6.4 yearsarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License